Paper

Effect of anesthesia on motor responses evoked by spinal neural prostheses during intraoperative procedures

, , , , , and

Published 19 March 2019 © 2019 IOP Publishing Ltd
, , Citation Amirali Toossi et al 2019 J. Neural Eng. 16 036003 DOI 10.1088/1741-2552/ab0938

1741-2552/16/3/036003

Abstract

Objective. The overall goal of this study was to investigate the effects of various anesthetic protocols on the intraoperative responses to intraspinal microstimulation (ISMS). ISMS is a neuroprosthetic approach that targets the motor networks in the ventral horns of the spinal cord to restore function after spinal cord injury. In preclinical studies, ISMS in the lumbosacral enlargement produced standing and walking by activating networks controlling the hindlimb muscles. ISMS implants are placed surgically under anesthesia, and refinements in placement are made based on the evoked responses. Anesthesia can have a significant effect on the responses evoked by spinal neuroprostheses; therefore, in preparation for clinical testing of ISMS, we compared the evoked responses under a common clinical neurosurgical anesthetic protocol with those evoked under protocols commonly used in preclinical studies. Approach. Experiments were conducted in seven pigs. An ISMS microelectrode array was implanted in the lumbar enlargement and responses to ISMS were measured under three anesthetic protocols: (1) isoflurane, an agent used pre-clinically and clinically, (2) total intravenous anesthesia (TIVA) with propofol as the main agent commonly used in clinical neurosurgical procedures, (3) TIVA with sodium pentobarbital, an anesthetic agent used mostly preclinically. Responses to ISMS were evaluated based on stimulation thresholds, movement kinematics, and joint torques. Motor evoked potentials (MEP) and plasma concentrations of propofol were also measured. Main results. ISMS under propofol anesthesia produced large and functional responses that were not statistically different from those produced under pentobarbital anesthesia. Isoflurane, however, significantly suppressed the ISMS-evoked responses. Significance. This study demonstrated that the choice of anesthesia is critical for intraoperative assessments of motor responses evoked by spinal neuroprostheses. Propofol and pentobarbital anesthesia did not overly suppress the effects of ISMS; therefore, propofol is expected to be a suitable anesthetic agent for clinical intraoperative testing of an intraspinal neuroprosthetic system.

Export citation and abstract BibTeX RIS

Access this article

The computer you are using is not registered by an institution with a subscription to this article. Please choose one of the options below.

Login

IOPscience login

Find out more about journal subscriptions at your site.

Purchase from

Article Galaxy
CCC RightFind

Purchase this article from our trusted document delivery partners.

Make a recommendation

To gain access to this content, please complete the Recommendation Form and we will follow up with your librarian or Institution on your behalf.

For corporate researchers we can also follow up directly with your R&D manager, or the information management contact at your company. Institutional subscribers have access to the current volume, plus a 10-year back file (where available).

Please wait… references are loading.
10.1088/1741-2552/ab0938