Paper

Experimental validation of a Tokamak neutron spectrometer based on Bonner spheres*

, , and

©2015 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd
, , Citation Jing Cao et al 2015 Chinese Phys. C 39 086001 DOI 10.1088/1674-1137/39/8/086001

1674-1137/39/8/086001

Abstract

In order to realize real-time fusion neutron spectrum diagnosis for the HL_2A Tokamak, a Bonner Sphere Spectrometer (BSS) array has been developed, consisting of eight polyethylene spheres (PS) with embedded 3He proportional counters. To validate its spectrometric capability, spectrum measurement of an 241Am-Be neutron source was carried out and is described. The Monte Carlo code Geant4 was used to calculate the response functions, taking this interference into consideration. Finally, the neutron spectrum was unfolded in the energy range from 10−9 MeV to 20 MeV. The unfolded spectrum has remarkable consistency with the ISO 8529-1 standard 241Am-Be neutron spectrum which is a preliminary demonstration that this BSS is reliable and practical.

Export citation and abstract BibTeX RIS

Footnotes

  • Supported by National Natural Science Foundation of China (11375195) and National Magnetic Confinement Fusion Science Program of China (2013GB104003)

10.1088/1674-1137/39/8/086001