Brought to you by:
OTHERS

Preliminary shielding analysis in support of the CSNS target station shutter neutron beam stop design

, , , , , , and

2011 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd
, , Citation Zhang Bin et al 2011 Chinese Phys. C 35 791 DOI 10.1088/1674-1137/35/8/017

1674-1137/35/8/791

Abstract

The construction of China Spallation Neutron Source (CSNS) has been initiated in Dongguan, Guangdong, China. Thus a detailed radiation transport analysis of the shutter neutron beam stop is of vital importance. The analyses are performed using the coupled Monte Carlo and multi-dimensional discrete ordinates method. The target of calculations is to optimize the neutron beamline shielding design to guarantee personal safety and minimize cost. Successful elimination of the primary ray effects via the two-dimensional uncollided flux and the first collision source methodology is also illustrated. Two-dimensional dose distribution is calculated. The dose at the end of the neutron beam line is less than 2.5 μSv/h. The models have ensured that the doses received by the hall staff members are below the standard limit required.

Export citation and abstract BibTeX RIS

Please wait… references are loading.
10.1088/1674-1137/35/8/017