DETECTORS AND EXPERIMENTAL METHODS

Design studies on the 4π γ-ray calorimeter for the ETF experiment at HIRFL-CSR

, , , , , , , , , , , and

2011 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd
, , Citation Xu Hu-Shan et al 2011 Chinese Phys. C 35 67 DOI 10.1088/1674-1137/35/1/014

1674-1137/35/1/67

Abstract

A high detection efficiency calorimeter which is used to detect γ-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETF) experiments.