ACCELERATORS

An untuned MA-loaded cavity for HIRFL-CSR

, , , , , , , and

2010 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd
, , Citation Mei Li-Rong et al 2010 Chinese Phys. C 34 1132 DOI 10.1088/1674-1137/34/8/018

1674-1137/34/8/1132

Abstract

In order to realize high energy density physics and plasma physics research at HIRFL-CSR, a magnetic alloy (MA)-loaded cavity has been studied. According to the theoretical calculation and simulation for the MA-loaded cavity, we achieved a better result. The MA-loaded cavity had a higher μQf value, with a higher shunt impedance and a higher accelerating gradient. The accelerating gradient was about 95 kV/m at 1.8003 MHz, 130 kV/m at 0.9000 MHz. Compared with the ferrite-loaded cavities that are used at HIRFL-CSR, with about 10 kV/m accelerating gradient, the MA-loaded cavity obviously has an advantage. The results of the theoretical calculation and the simulation, which meet the design requirements are in good agreement.

Export citation and abstract BibTeX RIS

10.1088/1674-1137/34/8/018