RF measurements of a C-band cavity beam position monitor*

, and

2008 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences
, , Citation Chu Jian-Hua et al 2008 Chinese Phys. C 32 385 DOI 10.1088/1674-1137/32/5/012

1674-1137/32/5/385

Abstract

RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUVFEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained are in reasonable agreement with the analytical estimations. Effective suppression of the common mode has been demonstrated. The position sensitivity over the test region of ±0.5 mm is about −21.58 dB/10 μm for the TM110 mode and is linear in the central region of the BPM cavity.

Export citation and abstract BibTeX RIS

Footnotes

  • Supported by Development Plan of the State Key Fundamental Research (2002CB713600)