Brought to you by:

Property measurement of the CsI(Tl) crystal prepared at IMP*

, , , , , , , , , , , , , , , and

2008 Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Sciences and the Institute of Modern Physics of the Chinese Academy of Sciences
, , Citation Chen Ruo-Fu et al 2008 Chinese Phys. C 32 135 DOI 10.1088/1674-1137/32/2/012

1674-1137/32/2/135

Abstract

Large-sized CsI(Tl) single crystals, ∼ ϕ100 mm × 350 mm, have been grown successfully, and this CsI(Tl) coupled with PD has been successfully utilized at RIBLL (the Radioactive Ion Beam Line in Lanzhou) to measure the energy of heavy ions as a stopping detector. The performances of CsI(Tl) detector coupled with PD and APD have been tested and compared, including the temperature dependence of scintillating light yield.

Export citation and abstract BibTeX RIS

Footnotes

  • Supported by Knowledge Innovation Project of Chinese Academy of Sciences (CKJCX2-SW-N18, CKJCX2-SW-N04)