THE CORES OF THE Fe Kα LINES IN ACTIVE GALACTIC NUCLEI: AN EXTENDED CHANDRA HIGH ENERGY GRATING SAMPLE

, , and

Published 2010 March 30 © 2010. The American Astronomical Society. All rights reserved.
, , Citation X. W. Shu et al 2010 ApJS 187 581 DOI 10.1088/0067-0049/187/2/581

0067-0049/187/2/581

ABSTRACT

We extend the study of the core of the Fe Kα emission line at ∼6.4 keV in Seyfert galaxies reported by Yaqoob & Padmanabhan using a larger sample observed by the Chandra high-energy grating (HEG). The sample consists of 82 observations of 36 unique sources with z < 0.3. Whilst heavily obscured active galactic nuclei are excluded from the sample, these data offer some of the highest precision measurements of the peak energy of the Fe Kα line, and the highest spectral resolution measurements of the width of the core of the line in unobscured and moderately obscured (NH < 1023 cm−2) Seyfert galaxies to date. From an empirical and uniform analysis, we present measurements of the Fe Kα line centroid energy, flux, equivalent width (EW), and intrinsic width (FWHM). The Fe Kα line is detected in 33 sources, and its centroid energy is constrained in 32 sources. In 27 sources, the statistical quality of the data is good enough to yield measurements of the FWHM. We find that the distribution in the line centroid energy is strongly peaked around the value for neutral Fe, with over 80% of the observations giving values in the range 6.38–6.43 keV. Including statistical errors, 30 out of 32 sources (∼94%) have a line centroid energy in the range 6.35–6.47 keV. The mean EW, among the observations in which a non-zero lower limit could be measured, was 53 ± 3 eV. The mean FWHM from the subsample of 27 sources was 2060 ± 230 km s−1. The mean EW and FWHM are somewhat higher when multiple observations for a given source are averaged. From a comparison with the Hβ optical emission-line widths (or, for one source, Brα), we find that there is no universal location of the Fe Kα line-emitting region relative to the optical broad-line region (BLR). In general, a given source may have contributions to the Fe Kα line flux from parsec-scale distances from the putative black hole, down to matter a factor ∼2 closer to the black hole than the BLR. We confirm the presence of the X-ray Baldwin effect, an anti-correlation between the Fe Kα line EW and X-ray continuum luminosity. The HEG data have enabled isolation of this effect to the narrow core of the Fe Kα line.

Export citation and abstract BibTeX RIS

1. INTRODUCTION

The narrow core (FWHM <10, 000 km s−1) of the Fe Kα fluorescent emission, peaking at ∼6.4 keV is a common and dominant feature of the X-ray spectrum of active galactic nuclei (AGNs) that have a 2–10 keV X-ray luminosity less than ∼1045 erg s−1 (e.g., Sulentic et al. 1998; Lubiński & Zdziarski 2001; Weaver et al. 2001; Perola et al. 2002; Yaqoob & Padmanabhan 2004 (hereafter YP04); Levenson et al. 2006; Winter et al. 2009). The luminosity in the core of the Fe Kα emission may be comparable to any additional, relativistically broadened Fe Kα line emission that may be present, and indeed, in many cases may be the only component of the Fe Kα line (e.g., see Guainazzi et al. 2006; Nandra et al. 2007; Miller 2007; Turner & Miller 2009; Bianchi et al. 2009). Measurement of the properties of the core of the Fe Kα line in AGNs is important for two principal reasons. One is to constrain the physical properties of the large-scale structure in the central engine. The peak energy of the Fe Kα line constrains the ionization state of the line-emitting matter, and the width of the line gives kinematic information that can be used to estimate the size and location of the X-ray reprocessor. The equivalent width (EW) of the Fe Kα line is a function of geometry, column density, covering factor, element abundances, and orientation of the line emitter. Another reason why spectroscopy of the Fe Kα line core is important is that it is necessary to model the narrow component of the line in order to deconvolve any relativistically broadened emission-line component that may be present. The Chandra high-energy grating (HEG; see Markert et al. 1995) is still unsurpassed in spectral resolution in the Fe K band, which at 6.4 keV is ∼39 eV, or ∼1860 km s−1 FWHM. This is a factor of ∼4 better than the spectral resolution of X-ray CCD detectors aboard XMM-Newton and Suzaku. Although broad Fe Kα emission lines are better studied with CCD spectrometers (due to their higher throughput), the Chandra HEG is well-suited for studying the narrow core of the Fe Kα line. One can then utilize the HEG measurements to deconvolve narrow and broad Fe Kα line components in lower spectral resolution data.

In YP04, the results of a uniform analysis of the properties of the Fe Kα emission-line core were presented, based on Chandra HEG data of a modest sample of 15 AGNs. There are now a larger number of Chandra HEG observations for which the data are available, and in the present paper we extend the study of YP04 to include 82 observations of 36 unique AGNs. The paper is organized as follows. In Section 2, we describe the observations and data. In Section 3, we describe the methodology and basic spectral-fitting results. In Section 4, we discuss the implications of the results for the properties of the core of narrow Fe Kα emission line in the HEG AGN sample. In Section 5, we investigate whether the narrow core of the Fe Kα line as isolated by the HEG, supports the so-called X-ray Baldwin effect (an anti-correlation between the line EW and X-ray luminosity and between the EW and a proxy for the accretion rate). In Section 6, we summarize our results and findings.

2. OBSERVATIONS AND DATA

The Chandra High Energy Transmission Grating Spectrometer (HETGS) consists of two grating assemblies, an HEG and a medium-energy grating (MEG), and it is the HEG that achieves the highest spectral resolution. The MEG has only half of the spectral resolution of the HEG and less effective area in the Fe K band, so our study will focus on the HEG data. Our study is based on data from Chandra HETGS AGN observations that were public as of 2008 September 30, filtering on several criteria. First, we selected non-blazar AGNs that had z < 0.3. This actually only omitted one source, PKS 2149 − 306 (z = 2.345), which is a high-luminosity radio-loud quasar (see Fang et al. 2001 for results from the Chandra grating observations). Since the centroid energy of the Fe Kα line appears at ∼6.4/(1 + z) keV, the line would appear at very different places on the instrumental effective area curve for very different values of z. In addition, the EW of the Fe Kα line is smaller by a factor (1 + z) compared to the rest-frame value. Therefore, a restriction on the sample redshift also helps to achieve a more homogeneous analysis. Next we required that the total counts in the full HEG bandpass (∼0.9–8 keV) was >1500, a condition which rejects spectra that have insufficient signal-to-noise ratios for our purpose. Relaxing this criterion would only have admitted two sources, PG 1404+226, and 1H 0707 − 495. We then selected those AGNs that are known to have X-ray absorbing column densities less than 1023  cm−2. The reason for this is that AGNs with higher column densities have X-ray spectra that are complex and measurements of the properties of even the narrow Fe Kα line core in such sources can become model dependent. Indeed, Murphy & Yaqoob (2009; hereafter MY09) showed, using Monte Carlo simulations of X-ray reprocessing, that inclination-angle and geometrical effects on the EW of the Fe Kα line become important for column densities greater than ∼1023  cm−2. Although the column density out of the line-of-sight could be larger than the line-of-sight column density, it is the simplicity of the observed spectrum that is the driver of the selection. We will present a study of heavily absorbed AGNs observed by the Chandra HEG elsewhere. Our approach in the present paper is to perform a very simple empirical analysis in order to obtain robust measurements of the basic narrow Fe Kα line core parameters that are not dependent on details of how the continuum is modeled. Our selection criteria then populate our sample with some sources that are formally classified as type 2 AGNs, whereas the study of YP04 included strictly only type 1 AGNs.

We also excluded 15 Chandra HETGS observations of M81 (∼435 ks exposure) from the study, as its very low luminosity and accretion rate set it apart from the rest of the bright AGNs in the sample (it is most often classified as a LINER harboring a low-luminosity AGN). The bolometric luminosity of M81 is only ∼10−5 of the Eddington luminosity (Young et al. 2007). We note that the results of some HETGS observations for M81, based on ∼280 ks exposure time have been presented by Young et al. (2007) who found K-shell emission lines from He-like and H-like Fe in addition to the Fe Kα line at ∼6.4 keV. Our final sample consists of 82 observations of 36 unique AGNs and includes all of the observations in YP04 (which we re-analyzed for the present paper). We note that our sample includes 3C 273, which is sometimes classified as a blazar. However, this source is variable and often shows Seyfert-like properties (e.g., Grandi & Palumbo 2007).

The Chandra data for the sample were reduced and HEG spectra were made as described in Yaqoob et al. (2003) and YP04. We used only the first orders of the grating data (combining the positive and negative arms). The mean HEG count rates ranged from 0.026 ± 0.001 count s−1 for the weakest source (PDS 456) to 1.161 ± 0.006 for the brightest source (IC 4329a). The exposure time ranged from ∼20 ks to ∼172 ks per observation, but was ∼50–120 ks for most of the sources. Nineteen sources were observed more than once, and the largest net exposure time from summed data from observations of the same source was ∼880 ks (NGC 3783). The observations, identified by target name, sequence number, and observation ID ("ObsID"), are listed in Table 1, along with the net exposure times for the spectra. Further details of all of the observations can be found in the Chandra data archive at http://cda.harvard.edu/chaser/. Higher-level products, including light curves and spectra for each observation can be found in the databases HotGAS (http://hotgas.pha.jhu.edu) and TGCat (http://tgcat.mit.edu/). Background was not subtracted since it is negligible over the energy range of interest (e.g., see Yaqoob et al. 2003). Note that the systematic uncertainty in the HEG wavelength scale is ∼433 km s−1 (∼11 eV) at 6.4 keV.3

Table 1. Parameters of the Core Fe K Line Emission (σ = 1 eV) from Chandra (HEG) Data

Source z Seq. Num E I EW F L ΔC
    /ObsID/exp (keV)   (eV) (2–10 keV) (2–10 keV)  
(1) (2) (3) (4) (5) (6) (7) (8) (9)
Fairall 9 0.0470160 700278 6.458+0.008−0.016 1.2+0.7−0.5 47+27−20 2.2 11.6 14.4
    /2088/79.9 (6.434 − 6.468) (0.5 − 2.2) (20 − 86)      
NGC 526a(1) 0.0190970 700840 6.400f 0+0.6−0 0+16−0 3.0 2.4 0
    /4376/29.1 ... (0 − 1.0) (0 − 27)      
NGC 526a(2) 0.0190970 700840 6.400+0.010−0.006 1.6+1.3−0.9 47+36−27 3.0 2.3 8.0
    /4437/29.4 (6.389 − 6.413) (0.3 − 3.5) (9.0 − 100)      
NGC 526a(total) 0.0190970 ... 6.394+0.012−0.006 1.0+0.7−0.7 28+20−20 2.9 2.4 5.0
    .../57.8 (6.380 − 6.414) (0 − 2.1) (0 − 59)      
Mrk 590 0.0263850 701005 6.403+0.016−0.009 0.8+0.4−0.4 78+46−37 0.85 1.3 14.9
    /4924/96.8 (6.386 − 6.435) (0.3 − 1.5) (31 − 155)      
NGC 985 0.0431430 700449 6.395+0.015−0.009 0.7+0.5−0.4 57+34−34 1.1 4.4 10.1
    /3010/77.7 (6.379 − 6.412) (0.2 − 1.5) (15 − 113)      
ESO 198−G24(1) 0.0455000 700900 6.400f 0.2+0.2−0.2 26+26−26 0.67 3.2 1.6
    /4817/80.3 ... (0 − 0.6) (0 − 74)      
ESO 198−G24(2) 0.0455000 700900 6.386+0.008−0.008 1.0+0.6−0.4 139+79−57 0.61 2.9 23.2
    /5315/71.5 (6.377 − 6.401) (0.4 − 1.8) (55 − 246)      
ESO 198−G24(total) 0.0455000 ... 6.394+0.008−0.009 0.6+0.3−0.3 71+43−33 0.64 3.1 17.3
    .../151.5 (6.377 − 6.409) (0.2 − 1.0) (25 − 126)      
3C 120 0.00330100 700454 6.412+0.009−0.009 2.5+1.1−1.0 47+20−19 4.7 11.7 20.1
    /3015/58.2 (6.396 − 6.428) (1.2 − 4.2) (22 − 78)      
NGC 2110(1) 0.00778900 700582 6.416+0.008−0.010 3.7+2.0−1.8 61+34−29 4.5 0.61 14.1
    /3143/34 (6.397 − 6.430) (1.3 − 6.8) (22 − 113)      
NGC 2110(2) 0.00778900 700582 6.407+0.015−0.016 3.1+2.5−2.0 52+41−34 4.5 0.60 10.4
    /3417/33.2 (6.384 − 6.434) (0.6 − 6.6) (10 − 110)      
NGC 2110(3) 0.00778900 700582 6.392+0.007−0.002 4.9+1.4−1.3 80+23−21 4.5 0.60 51.5
    /3418/76.1 (6.384 − 6.400) (3.1 − 7.0) (51 − 114)      
NGC 2110(4) 0.00778900 700841 6.392+0.008−0.002 3.9+0.9−0.9 92+23−23 3.1 0.41 70.8
    /4377/96.4 (6.384 − 6.400) (2.6 − 5.3) (62 − 127)      
NGC 2110(total) 0.00778900 ... 6.399+0.001−0.008 3.9+0.7−0.6 75+14−11 3.8 0.51 134
    .../200.4 (6.391 − 6.400) (3.0 − 4.9) (58 − 95)      
PG 0844+349(1) 0.0640000 701023 6.364+0.007−0.009 0.6+0.4−0.3 118+83−58 0.42 4.0 12.4
    /5599/57.2 (6.352 − 6.375) (0.2 − 1.3) (40 − 262)      
PG 0844+349(2) 0.0640000 701023 6.400f 0.2+0.3−0.2 36+47−36 0.55 5.4 1.3
    /6244/50.2 ... (0 − 0.7) (0 − 116)      
PG 0844+349(3) 0.0640000 701023 6.400f 0.1+0.3−0.1 13+34−13 0.77 7.6 0.2
    /6245/36.2 ... (0 − 0.6) (0 − 76)      
PG 0844+349(total) 0.0640000 ... 6.366+0.008−0.008 0.3+0.3−0.1 52+43−20 0.55 5.4 10.2
    .../141.2 (6.356 − 6.381) (0.1 − 0.7) (16 − 112)      
Mrk 705 0.0291500 700995 6.400f 0.4+0.6−0.4 26+48−26 1.3 2.6 0.5
    /4914/21.3 ... (0 − 1.6) (0 − 113)      
MCG−5-23-16(1) 0.00827900 700311 6.394+0.007−0.007 7.2+2.1−1.9 55+18−14 10.5 1.6 47
    /2121/76.2 (6.386 − 6.402) (4.6 − 10) (35 − 81)      
MCG−5-23-16(2) 0.00827900 701171 6.394+0.008−0.008 5.1+2.5−2.0 40+20−15 10.6 1.6 18.3
    /6187/30.1 (6.384 − 6.403) (2.3 − 8.6) (18 − 68)      
MCG−5-23-16(3) 0.00827900 701171 6.395+0.015−0.010 6.4+3.0−2.8 51+24−22 10.5 1.6 16.7
    /7240/20.3 (6.371 − 6.411) (2.6 − 10) (21 − 87)      
MCG−5-23-16(total) 0.00827900 ... 6.394+0.002−0.001 6.4+1.4−1.3 50+11−10 10.5 1.6 80.9
    .../96.1 (6.387 − 6.402) (4.6 − 8.4) (36 − 65)      
NGC 3227 0.00385900 700165 6.388+0.021−0.012 1.0+1.0−0.9 32+32−29 2.5 0.08 3.1
    /860/47 ... (0 − 2.6) (0 − 83)      
NGC 3516(1) 0.00883600 700270 6.395+0.002−0.006 3.8+1.0−0.9 106+28−25 3.0 0.51 69.3
    /2080/74.5 (6.383 − 6.398) (2.5 − 5.2) (70 − 145)      
NGC 3516(2) 0.00883600 700270 6.406+0.009−0.008 3.7+1.5−1.2 155+61−51 1.9 0.33 38.2
    /2431/36.2 (6.397 − 6.416) (2.1 − 5.9) (87 − 246)      
NGC 3516(3) 0.00883600 700270 6.398+0.002−0.008 2.4+0.9−0.7 83+28−26 2.3 0.39 40.6
    /2482/89.5 (6.389 − 6.407) (1.4 − 3.6) (47 − 121)      
NGC 3516(4) 0.00883600 701337 6.407+0.016−0.010 2.5+1.4−1.2 40+23−19 5.2 0.89 12.5
    /7281/43.1 (6.373 − 6.430) (0.8 − 4.6) (13 − 74)      
NGC 3516(5) 0.00883600 701337 6.398+0.009−0.008 2.3+1.4−1.1 45+27−22 4.4 0.76 12.9
    /7282/42.1 (6.383 − 6.414) (0.8 − 4.3) (16 − 83)      
NGC 3516(6) 0.00883600 701337 6.430+0.008−0.008 3.8+1.6−1.5 53+23−21 6.5 1.1 20.6
    /8450/39.1 (6.415 − 6.439) (1.7 − 6.2) (24 − 87)      
NGC 3516(7) 0.00883600 701337 6.407+0.030−0.010 2.7+1.6−1.1 36+21−15 6.7 1.2 14.4
    /8451/48.1 (6.389 − 6.439) (1.1 − 4.9) (15 − 65)      
NGC 3516(8) 0.00883600 701337 6.431+0.009−0.033 2.9+2.2−1.8 41+32−24 6.1 1.0 7.2
    /8452/20.2 (6.390 − 6.447) (0.5 − 6.2) (7.0 − 88)      
NGC 3516(total) 0.00883600 ... 6.398+0.001−0.001 2.8+0.4−0.4 58+9−8 4.1 0.70 161.7
    .../386.5 (6.397 − 6.400) (2.2 − 3.4) (46 − 71)      
NGC 3783(1) 0.00973000 700045 6.396+0.007−0.008 4.4+1.3−1.4 56+17−18 6.8 1.4 36.6
    /373/57.2 (6.387 − 6.404) (2.5 − 6.4) (32 − 88)      
NGC 3783(2) 0.00973000 700280 6.403+0.001−0.008 4.2+0.8−0.8 61+11−12 5.9 1.2 105.2
    /2090/167.8 (6.395 − 6.404) (3.1 − 5.4) (45 − 78)      
NGC 3783(3) 0.00973000 700281 6.395+0.001−0.001 4.3+0.8−0.8 62+12−11 5.9 1.2 109.2
    /2091/171 (6.387 − 6.397) (3.2 − 5.5) (46 − 79)      
NGC 3783(4) 0.00973000 700282 6.396+0.001−0.001 5.0+0.8−0.8 72+12−11 6.0 1.3 146.6
    /2092/167.6 (6.394 − 6.401) (3.9 − 6.2) (56 − 90)      
NGC 3783(5) 0.00973000 700283 6.396+0.001−0.001 5.8+0.9−0.9 63+10−10 8.2 1.7 154.2
    /2093/168.2 (6.394 − 6.397) (4.5 − 7.1) (49 − 77)      
NGC 3783(6) 0.00973000 700284 6.396+0.008−0.001 4.0+0.8−0.8 48+10−9 7.2 1.5 89.3
    /2094/168.3 (6.394 − 6.404) (2.9 − 5.2) (35 − 62)      
NGC 3783(total) 0.00973000 ... 6.396+0.001−0.001 4.6+0.4−0.3 60+5−4 6.6 1.4 635.9
    .../888.7 (6.395 − 6.396) (4.1 − 5.1) (53 − 66)      
NGC 4051 0.00233600 700164 6.414+0.006−0.010 1.6+0.9−0.5 94+41−34 1.7 0.02 26.5
    /859/80.8 (6.398 − 6.422) (0.9 − 2.8) (49 − 152)      
NGC 4151(1) 0.00331900 700007 6.396+0.001−0.001 17.2+2.7−2.6 148+23−22 7.8 0.19 202.3
    /335/48 (6.395 − 6.398) (13 − 21) (117 − 182)      
NGC 4151(2) 0.00331900 700491 6.396+0.001−0.001 13.9+1.6−1.4 59+8−6 17.4 0.42 306.5
    /3052/156.6 (6.394 − 6.396) (11 − 16) (50 − 69)      
NGC 4151(3) 0.00331900 700491 6.396+0.001−0.001 14.0+2.1−1.9 56+9−7 18.3 0.44 177.1
    /3480/92.9 (6.394 − 6.397) (11 − 17) (46 − 69)      
NGC 4151(4) 0.00331900 701493 6.396+0.008−0.001 10.0+1.8−2.0 162+30−31 4.3 0.10 131.1
    /7829/50 (6.395 − 6.404) (7.4 − 12) (119 − 206)      
NGC 4151(5) 0.00331900 701494 6.388+0.008−0.001 11.1+2.6−2.5 44+10−10 18.4 0.45 63.4
    /7830/50.2 (6.386 − 6.397) (7.6 − 14) (30 − 59)      
NGC 4151(total) 0.00331900 ... 6.396+0.001−0.001 13.3+0.9−0.9 65+5−4 14.9 0.36 801.5
    .../389.9 (6.395 − 6.396) (12 − 14) (59 − 72)      
Mrk 766 0.0129290 700123 6.425+0.016−0.010 0.8+0.6−0.5 37+27−23 2.3 0.86 7.9
    /1597/90.5 (6.400 − 6.450) (0.2 − 1.6) (9.0 − 73)      
3C 273(1) 0.158340 790020 6.313+0.013−0.015 2.4+1.7−1.5 12+9−7 12.4 811.4 6.7
    /459/39.1 (6.291 − 6.334) (0.4 − 4.8) (2.0 − 24)      
3C 273(2) 0.158340 790057 6.292+0.007−0.007 3.2+1.9−1.7 20+13−10 11.2 734 9.25
    /2463/27.1 (6.279 − 6.301) (0.8 − 6.0) (5.0 − 38)      
3C 273(3) 0.158340 790074 6.275+0.011−0.010 2.5+1.8−1.5 22+15−13 8.4 559 7.2
    /3456/25 (6.259 − 6.293) (0.4 − 5.2) (3.0 − 45)      
3C 273(4) 0.158340 790075 6.319+0.008−0.012 2.2+1.4−1.7 20+12−16 8.3 552 4.3
    /3457/25.4 ... (0.0 − 4.4) (0.0 − 39)      
3C 273(5) 0.158340 790076 6.412+0.021−0.029 1.7+1.6−1.3 16+14−12 8.1 538 4.0
    /3573/30.2 ... (0.0 − 4.1) (0.0 − 38)      
3C 273(6) 0.158340 790087 6.400f 0+0.9−0 0+7−0 11.9 794 0
    /4430/27.6 ... (0.0 − 1.6) (0.0 − 10)      
3C 273(7) 0.158340 790089 6.400f 0.0+0.4−0.0 0+3−0 8.0 528 2.0
    /5169/30.2 ... (0.0 − 0.9) (0.0 − 7.0)      
3C 273(total) 0.158340 ... 6.319+0.007−0.013 1.0+0.6−0.6 7+4−4 9.9 654 8.0
    .../201.1 (6.292 − 6.328) (0.2 − 1.8) (1.0 − 13)      
NGC 4593 0.00900000 700279 6.399+0.008−0.008 2.7+1.0−0.8 59+20−18 4.5 0.81 33.3
    /2089/79.9 (6.390 − 6.408) (1.6 − 4.1) (34 − 88)      
MCG−6-30-15(1) 0.00774900 700105 6.384+0.015−0.009 1.4+0.6−0.6 28+12−12 4.7 0.62 15.9
    /433/128.2 (6.374 − 6.407) (0.6 − 2.3) (12 − 46)      
MCG−6-30-15(2) 0.00774900 700845 6.399+0.008−0.008 1.2+0.6−0.4 26+12−9 4.5 0.59 17.4
    /4759/161.1 (6.389 − 6.409) (0.6 − 2.1) (17 − 44)      
MCG−6-30-15(3) 0.00774900 700845 6.382+0.009−0.013 0.7+0.4−0.5 14+9−10 4.4 0.58 5.5
    /4760/172.3 (6.359 − 6.400) (0.0 − 1.3) (0 − 27)      
MCG−6-30-15(4) 0.00774900 700845 6.400+0.016−0.018 0.8+0.6−0.4 17+11−8 4.7 0.63 7.4
    /4761/158.8 (6.375 − 6.424) (0.2 − 1.7) (4.0 − 33)      
MCG−6-30-15(5) 0.00774900 700845 6.342+0.018−0.021 1.8+1.3−1.1 37+27−22 4.6 0.61 7.6
    /4762/38.2 (6.312 − 6.368) (0.3 − 3.7) (6.0 − 77)      
MCG−6-30-15(total) 0.00774900 ... 6.390+0.002−0.008 0.8+0.3−0.2 18+5−5 4.5 0.59 29.1
    .../582 (6.375 − 6.399) (0.5 − 1.2) (10 − 25)      
IRAS 13349+2438(1) 0.107640 700902 6.400f 0.04+0.1−0.04 8+22−8 0.39 11.5 0.3
    /4819/161.9 ... (0.0 − 0.2) (0.0 − 46)      
IRAS 13349+2438(2) 0.107640 700902 6.428+0.011−0.008 0.3+0.3−0.1 77+60−31 0.33 9.7 12.9
    /4820/137.5 (6.417 − 6.440) (0.1 − 0.7) (23 − 160)      
IRAS 13349+2438(total) 0.107640 ... 6.426+0.013−0.009 0.2+0.1−0.1 40+22−19 0.36 10.7 9.7
    .../294.5 (6.411 − 6.441) (0.0 − 0.4) (0.0 − 83)      
IC 4329A 0.0160540 700367 6.399+0.006−0.005 3.7+1.6−1.6 19+8−8 17.5 10.1 14.3
    /2177/60.1 (6.387 − 6.411) (1.5 − 6.1) (8.0 − 31)      
Mrk 279 0.0304510 700501 6.381+0.008−0.007 1.1+0.4−0.4 66+28−22 1.4 2.9 23.4
    /3062/116.1 (6.372 − 6.395) (0.5 − 1.7) (31 − 107)      
NGC 5506 0.00618100 700214 6.398+0.008−0.001 5.7+1.3−1.2 66+15−14 6.6 0.55 80.6
    /1598/90 (6.396 − 6.406) (4.1 − 7.6) (48 − 88)      
NGC 5548(1) 0.0171750 700142 6.410+0.016−0.009 1.8+0.8−0.7 58+27−22 2.7 1.8 22.1
    /837/82.3 (6.385 − 6.434) (0.9 − 3.0) (29 − 98)      
NGC 5548(2) 0.0171750 700485 6.394+0.008−0.007 1.9+0.5−0.5 55+15−14 3.1 2.0 42.2
    /3046/153.9 (6.386 − 6.403) (1.2 − 2.7) (35 − 78)      
NGC 5548(total) 0.0171750 ... 6.402+0.001−0.010 1.9+0.4−0.5 56+13−14 2.9 1.9 61.8
    .../232.7 (6.386 − 6.410) (1.3 − 2.5) (39 − 75)      
Mrk 290(1) 0.0295770 700629 6.386+0.012−0.011 1.0+0.7−0.6 53+37−32 1.8 3.5 9.0
    /3567/55.1 (6.367 − 6.400) (0.2 − 2.0) (11 − 106)      
Mrk 290(2) 0.0295770 700629 6.398+0.026−0.032 0.5+0.4−0.4 36+28−29 1.3 2.5 3.8
    /4399/85.1 ... (0 − 1.2) (0 − 85)      
Mrk 290(3) 0.0295770 700629 6.400f 0.4+0.4−0.3 20+22−15 1.8 3.6 1.8
    /4441/60.9 ... (0 − 1.0) (0 − 52)      
Mrk 290(4) 0.0295770 700629 6.400f 0.3+0.4−0.3 15+21−15 1.8 3.6 0.8
    /4442/50.2 ... (0 − 1.0) (0 − 51)      
Mrk 290(total) 0.0295770 ... 6.398+0.009−0.016 0.5+0.3−0.3 27+18−16 1.6 3.2 10.8
    .../247.3 (6.374 − 6.414) (0.2 − 0.9) (11 − 50)      
PDS 456 0.184000 700742 6.400f 0.04+0.06−0.04 4+13−4 0.40 37.3 0.11
    /4063/145.2 ... (0 − 0.2) (0 − 33)      
E1821+643 0.297000 700215 6.453+0.005−0.007 0.7+0.4−0.3 26+13−12 1.4 362.5 13.1
    /1599/101.3 (6.445 − 6.463) (0.3 − 1.3) (11 − 46)      
3C 382(1) 0.0578700 700991 6.374+0.017−0.016 1.0+1.0−0.8 16+15−13 5.5 43.2 3.7
    /4910/55 ... (0 − 2.5) (0 − 39)      
3C 382(2) 0.0578700 700991 6.408+0.013−0.010 1.3+0.9−0.8 21+15−13 4.9 38.5 7.1
    /6151/64.9 (6.382 − 6.429) (0.2 − 2.6) (3.0 − 43)      
3C 382(total) 0.0578700 ... 6.368+0.038−0.009 0.9+0.6−0.6 14+9−9 5.2 40.6 6.2
    .../118 (6.351 − 6.446) (0.1 − 1.8) (2.0 − 28)      
IRAS 18325 − 5926(1) 0.0202310 700587 6.400f 0.05+0.35−0.05 2+15−2 2.1 1.9 0.04
    /3148/56.9 ... (0 − 0.7) (0.0 − 31)      
IRAS 18325 − 5926(2) 0.0202310 700587 6.400f 0.2+0.4−0.2 5+12−5 3.1 2.8 0.2
    /3452/51.1 ... (0 − 1.0) (0.0 − 29)      
IRAS 18325 − 5926(total) 0.0202310 ... 6.400f 0.1+0.3−0.1 5+9−5 2.5 2.3 0.2
    .../106.2 ... (0 − 0.6) (0 − 21)      
4C+74.26(1) 0.104000 700679 6.258+0.013−0.014 1.2+1.0−0.8 37+30−25 2.5 65.1 6.8
    /4000/37.7 (6.236 − 6.278) (0.2 − 2.6) (6.0 − 79)      
4C+74.26(2) 0.104000 700679 6.347+0.011−0.010 1.0+1.0−0.8 30+30−24 2.6 67.1 4.7
    /5195/31.8 (6.322 − 6.366) (0.0 − 2.4) (0.0 − 73)      
4C+74.26(total) 0.104000 ... 6.252+0.011−0.008 1.0+0.7−0.5 28+18−14 2.5 66.2 9.5
    .../66.1 (6.242 − 6.265) (0.3 − 2.0) (8.0 − 54)      
Mrk 509 0.0343970 700277 6.445+0.015−0.009 2.2+1.2−1.0 34+17−16 5.8 15.6 13.7
    /2087/58.7 (6.427 − 6.462) (0.8 − 3.9) (12 − 59)      
NGC 7213(1) 0.00583900 701410 6.395+0.003−0.008 2.2+0.6−0.6 88+25−23 2.3 0.18 50.9
    /7742/115.3 (6.386 − 6.403) (1.4 − 3.1) (57 − 126)      
NGC 7213(2) 0.00583900 701410 6.412+0.016−0.009 2.3+1.3−1.1 91+50−44 2.4 0.18 16.5
    /8590/35.1 (6.395 − 6.431) (0.9 − 4.2) (35 − 164)      
NGC 7213(total) 0.00583900 ... 6.395+0.008−0.001 2.2+0.5−0.6 86+22−22 2.3 0.18 63.3
    .../150 (6.387 − 6.404) (1.4 − 3.0) (56 − 120)      
NGC 7314(1) 0.00474300 700455 6.397+0.015−0.018 1.3+1.4−1.1 32+34−25 3.6 0.18 3.8
    /3016/28.9 ... (0.0 − 3.3) (0.0 − 81)      
NGC 7314(2) 0.00474300 700455 6.422+0.008−0.009 1.9+0.9−0.9 53+26−22 3.3 0.16 18
    /3719/68.4 (6.387 − 6.437) (0.8 − 3.2) (23 − 90)      
NGC 7314(total) 0.00474300 ... 6.413+0.017−0.024 1.5+0.9−0.8 41+24−22 3.4 0.17 15.5
    .../95.7 (6.387 − 6.437) (0.5 − 2.8) (19 − 76)      
Ark 564 0.0246840 700168 6.400f 0.6+0.4−0.4 25+20−16 2.7 3.7 2.1
    /863/49.4 ... (0.0 − 1.3) (0.0 − 58)      
MR 2251-178 0.0639800 700416 6.412+0.008−0.009 0.7+0.4−0.4 22+12−13 2.7 25.3 7.7
    /2977/148.7 (6.396 − 6.427) (0.1 − 1.3) (3.0 − 40)      
NGC 7469(1) 0.0163170 700395 6.388+0.007−0.007 2.6+0.8−0.7 93+30−24 2.7 1.6 46.1
    /2956/79.9 (6.380 − 6.396) (1.6 − 3.8) (58 − 137)      
NGC 7469(2) 0.0163170 700586 6.437+0.008−0.017 1.6+0.8−0.7 60+33−25 2.4 1.5 16.7
    /3147/69.8 (6.412 − 6.451) (0.6 − 2.7) (23 − 104)      
NGC 7469(total) 0.0163170 ... 6.388+0.002−0.008 1.9+0.6−0.5 72+21−20 2.6 1.5 50.9
    .../147.2 (6.379 − 6.397) (1.2 − 2.8) (44 − 104)      

Notes. Results from Chandra HEG data, fitted with a power law plus Gaussian emission-line model in the 2–7 keV band, with the line width fixed at 1 eV. All parameters are quoted in the source rest frame. Statistical errors are for the 68% confidence level, while parentheses show the 90% confidence level ranges of the parameters. The number of interesting parameters assumed for calculating the statistical errors was equal to the number of free parameters in the Gaussian component of the model. Column 1: redshifts obtained from NASA Extragalactic Database (NED); Column 2: observation sequence number, ID, and exposure time in ks; Column 3: Gaussian line centroid energy; Column 4: emission-line intensity in units of 10−5 photons cm−2 s−1; Column 5: emission-line EW; Column 6: F is the estimated 2–10 keV observed flux in units of 10−11 erg cm−2 s−1. The power-law continuum was extrapolated to 10 keV; Column 7: L is the estimated unabsorbed 2–10 keV source-frame luminosity (using the 2–10 keV estimated flux), in units of 1043 erg s−1; Column 8: the decrease in the fit statistic, C, when the narrow, two-parameter emission line was added to the continuum-only model.

Download table as:  ASCIITypeset images: 1 2 3 4

3. SPECTRAL FITTING METHODOLOGY AND RESULTS

The spectra were analyzed using the spectral-fitting package XSPEC (Arnaud 1996). Since we are interested in utilizing the highest possible spectral resolution available, we used spectra binned at 0.0025 Å, and this amply oversamples the HEG resolution (0.012 Å FWHM). The C-statistic was used for minimization. All model parameters will be referred to the source frame. Our method is simply to fit a simple continuum plus Gaussian emission-line model over the 2–7 keV band for each spectrum. Above 7 keV the HEG effective area rapidly decreases. We found, as in YP04, that if the energy band is restricted any further the constraints on the Fe Kα line parameters do not improve because when the intrinsic line width is free there is degeneracy of the line parameters with the continuum slope. In most cases, a simple power-law continuum was adequate, but for some sources an additional uniform, neutral, absorber component was included (namely NGC 2110, MCG−5-23-16, NGC 4151, and NGC 5506). In no case was a column density greater than 4.3+0.4−0.3 × 1022 cm−2 required. Galactic absorption was not included for any of the sources because such small column densities have little effect above 2 keV. Thus, there were a maximum of six free parameters in the model, namely the power-law slope and its overall normalization, Γ, the column density, NH, the centroid energy of the Gaussian emission-line component, E0, its flux, IFeK, and its width, σFeK. The approach of using an oversimplified continuum model is necessitated by the limited bandpass of the HEG data (∼2–7 keV) but since we are interested in the narrow core of the Fe Kα emission line, at the spectral resolution of the HEG, this is not restrictive. Obviously, use of such an empirical model means that we should not assign a physical meaning to Γ and NH.

The signal-to-noise ratio of the spectra showed a wide range so we followed a systematic, two-step procedure that accounts for this. In the first round of analysis we fixed the emission-line width, σFeK, at 1 eV (corresponding to ∼110 km s−1 FWHM at 6.4 keV), a value well below the instrument resolution, because the line width could not be constrained in all the data sets. Uniformly freezing the line width for all the data sets then picks up the narrowest, unresolved core component of the emission line for all the data sets. In the second round of analysis we allowed the line width to float. Where multiple observations of a given source were available we constructed and fitted spectra that were averaged over all of the observations, in addition to fitting data from the individual observations. Inter-observation variability will be discussed in Section 4.4.

The results of this first round of analysis are shown in Table 1 which shows the derived EW in addition to the other Fe Kα line parameters. Note that since the models were fitted by first folding through the instrument response before comparing with the data, the derived line parameters do not need to be corrected for instrumental response. We do not give the best-fitting values of Γ or NH in Table 1 because the values derived using the simplistic continuum model are not physically meaningful but are simply parameterizations. The 2–10 keV continuum fluxes and luminosities shown in Table 1 were obtained by extrapolating the best-fitting model up to 10 keV. We caution that such extrapolation could give inaccurate fluxes and luminosities if the continuum shape is significantly different in the 7–10 keV band compared to the extrapolated model. The fluxes are not corrected for absorption, but the luminosities are. The ΔC values shown in Table 1 correspond to the decrease in C when the narrow, two-parameter emission line was added to the continuum-only model, and is therefore a measure of the significance of the emission line.

We found that in some cases (14 observations of 10 sources, plus the summed spectrum of IRAS 18325 − 5926) the Fe Kα line centroid energy could not be constrained, and in such cases the centroid energy was fixed at 6.40 keV. In 12 of these data sets the Fe Kα line was not detected at a confidence level greater than 90% and for these cases only an upper limit on the EW, and line flux, IFeK, could be obtained. Two sets of statistical errors are given for the Fe Kα line parameters in Table 1 for each spectral fit. The first set corresponds to 68% confidence (ΔC = 2.279, or 0.989, depending on whether there were two parameters or one parameter free respectively in the Gaussian component). These "1σ" errors are useful for performing standard statistical analyses on the model parameters. However, as a more conservative measure, the 90% confidence range (for the appropriate number of free parameters of the Gaussian component) for each line parameter is also given in Table 1 (values in parentheses). For the 90% confidence ranges ΔC = 4.605 and 2.706 for two parameters and one parameter free, respectively.

We also found that in some sources that have multiple observations, the Fe Kα line parameters were sometimes better constrained from some of the individual observations than from the averaged spectra because the latter may contain contributions from data in which the Fe Kα line was relatively weaker in EW. Detailed interpretation of the results in Table 1 will be given in Section 4.

In the second round of spectral fitting we allowed the intrinsic width of the Gaussian emission-line component to be a free parameter. However, in situations when the signal-to-noise ratio of the Fe Kα emission line is too poor, the Gaussian model emission-line component can become very broad as it then begins to model the continuum, resulting in values of the width that are not actually related to the physical width of the emission line. As a very loose initial criterion, we rejected all cases in which a three-parameter Gaussian component was detected with less than 95% confidence (corresponding to rejecting fits that gave ΔC < 7.8). This rough criterion immediately rejected fits for which the fits actually became unstable and left 26 unique sources and 65 data sets, including 14 spectra averaged over multiple observations. The results for all of the fits with ΔC > 7.8 are shown in Table 2, in which the three-parameter, 68% statistical errors, and 90% confidence ranges on the line parameters are given. The Fe Kα line width is given as an FWHM in km s−1 rather than the Gaussian width, σFeK.

Table 2. Parameters of the Core Fe K Line Emission (σ free) from Chandra (HEG) Data

Source Ea Ib EWc FWHMd (Fe Kα) FWHMd (Hβ) Referencee
(1) (2) (3) (4) (5) (6) (7)
Fairall 9 6.370+0.347−0.161 (6.137 − 6.906) 5.5+13.3−3.6 (1.5 − 22.9) 228+555−149 (63 − 954) 18100+76840−12390 (5100 − 121780) 6270 ± 290 N06
Mrk 590 6.407+0.036−0.033 (6.358 − 6.461) 1.6+1.0−0.8 (0.6 − 3.0) 171+103−84 (64 − 317) 4350+6060−2030 (1740 − 15420) 2640 M03
NGC 985 6.407+0.070−0.076 (6.281 − 6.509) 2.2+1.6−1.2 (0.6 − 4.4) 170+127−94 (46 − 344) 9550+11190−4760 (3810 − 29590) 7500 M03
ESO 198−G24(2) 6.385+0.013−0.019 (6.353 − 6.404) 1.2+0.7−0.6 (0.4 − 2.2) 158+105−80 (57 − 304) <4220 (0 − 5840) 6400 Z05
ESO 198−G24(total) 6.382+0.025−0.043 (6.306 − 6.426) 0.9+0.8−0.4 (0.3 − 2.1) 117+110−50 (40 − 279) 2940+8830−1880 (0 − 15500) ... ...
3C 120 6.410+0.016−0.015 (6.389 − 6.439) 3.4+1.9−1.5 (1.4 − 6.0) 66+37−30 (27 − 117) 2230+2280−1650 (0 − 5950) 5370 W09
NGC 2110(1) 6.389+0.098−0.026 (6.341 − 6.521) 6.8+10.1−3.3 (2.5 − 20.1) 116+171−56 (43 − 342) 4070+15260−2470 (0 − 24160) 1200f M07
NGC 2110(3) 6.394+0.009−0.007 (6.384 − 6.407) 5.3+2.1−1.8 (2.9 − 8.2) 87+35−29 (48 − 135) <2540 (0 − 3160) ... ...
NGC 2110(4) 6.395+0.010−0.010 (6.381 − 6.409) 5.2+1.7−1.5 (3.3 − 7.6) 127+40−37 (80 − 184) 2510+2070−1240 (940 − 5600) ... ...
NGC 2110(total) 6.397+0.006−0.006 (6.389 − 6.405) 5.3+1.0−1.2 (3.8 − 6.6) 103+21−23 (75 − 129) 2320+810−800 (1320 − 3510) ... ...
PG 0844+349(1) 6.583+0.122−0.116 (6.422 − 6.770) 2.5+1.6−1.3 (0.8 − 4.7) 587+384−303 (189 − 1117) 20320+13170−8080 (8900 − 44490) 2150 Z05
MCG−5-23-16(1) 6.384+0.011−0.011 (6.369 − 6.399) 10.6+3.2−3.1 (6.5 − 15.0) 82+25−24 (51 − 117) 2630+1340−880 (1470 − 4560) 1450g L02
MCG−5-23-16(2) 6.408+0.024−0.033 (6.359 − 6.452) 8.1+5.1−4.1 (2.8 − 15.1) 65+42−33 (23 − 122) 3810+4880−1690 (1540 − 18350) ... ...
MCG−5-23-16(3) 6.388+0.019−0.024 (6.352 − 6.416) 9.6+5.5−4.7 (3.7 − 18.0) 78+44−38 (30 − 146) 2660+4150−1580 (610 − 10420) ... ...
MCG−5-23-16(total) 6.388+0.009−0.009 (6.377 − 6.400) 9.0+2.1−2.2 (6.1 − 12.1) 71+17−17 (48 − 96) 2560+1130−900 (1390 − 4180) ... ...
NGC 3516(1) 6.392+0.005−0.006 (6.385 − 6.399) 3.9+1.2−1.3 (2.3 − 5.6) 110+34−36 (65 − 158) <1670 (0 − 3160) 3353 ± 310 P04
NGC 3516(2) 6.408+0.010−0.011 (6.393 − 6.422) 4.4+2.0−1.7 (2.2 − 7.2) 186+85−71 (93 − 306) 1740+1420−1210 (0 − 4020) ... ...
NGC 3516(3) 6.402+0.017−0.014 (6.382 − 6.425) 4.5+1.6−1.4 (2.7 − 6.7) 157+56−49 (94 − 234) 4290+2180−1470 (2450 − 8050) ... ...
NGC 3516(4) 6.409+0.023−0.025 (6.374 − 6.442) 4.2+3.1−2.0 (1.6 − 8.3) 67+51−31 (26 − 134) 3220+3020−1630 (960 − 8190) ... ...
NGC 3516(5) 6.354+0.057−0.079 (6.241 − 6.431) 5.1+4.1−2.6 (1.7 − 10.6) 101+81−52 (34 − 209) 8480+7050−4700 (3110 − 18840) ... ...
NGC 3516(6) 6.407+0.033−0.034 (6.364 − 6.451) 7.6+3.7−3.4 (3.3 − 12.6) 108+52−49 (47 − 178) 6030+3550−2430 (2970 − 11240) ... ...
NGC 3516(7) 6.414+0.017−0.017 (6.389 − 6.437) 4.2+2.4−2.0 (1.7 − 7.5) 55+32−26 (23 − 99) 2290+2150−1310 (460 − 5900) ... ...
NGC 3516(total) 6.404+0.007−0.007 (6.395 − 6.413) 4.4+0.8−0.7 (3.4 − 5.5) 91+17−14 (71 − 114) 3180+880−670 (2310 − 4390) ... ...
NGC 3783(1) 6.396+0.014−0.013 (6.377 − 6.415) 5.4+2.7−2.6 (2.3 − 9.1) 69+36−33 (30 − 118) <4670 (0 − 5780) 3570 ± 190 N06
NGC 3783(2) 6.401+0.006−0.0063 (6.392 − 6.410) 5.1+1.5−1.1 (3.6 − 7.1) 75+21−16 (53 − 104) 1930+1080−900 (750 − 3490) ... ...
NGC 3783(3) 6.391+0.008−0.008 (6.380 − 6.401) 6.2+1.4−1.5 (4.3 − 8.2) 90+22−21 (63 − 120) 2700+1180−1050 (1410 − 4430) ... ...
NGC 3783(4) 6.395+0.005−0.006 (6.388 − 6.402) 6.0+1.3−1.4 (4.2 − 7.8) 88+19−21 (62 − 114) 1860+880−1140 (0 − 3140) ... ...
NGC 3783(5) 6.395+0.004−0.005 (6.388 − 6.401) 6.3+1.5−1.1(4.8 − 8.3) 69+16−12 (53 − 91) 1280+720−630 (0 − 2260) ... ...
NGC 3783(6) 6.399+0.006−0.006 (6.391 − 6.408) 4.7+1.2−1.2 (3.2 − 6.4) 57+14−15 (39 − 77) 1520+890−940 (0 − 2750) ... ...
NGC 3783(total) 6.396+0.003−0.002 (6.393 − 6.399) 5.6+0.5−0.6 (4.8 − 6.3) 74+7−8 (63 − 83) 1750+360−360 (1270 − 2240) ... ...
NGC 4051 6.417+0.039−0.036 (5.750 − 6.474) 3.5+1.4−1.4 (1.6 − 5.5) 195+79−78 (89 − 307) 6430+11800−2860 (2840 − 479470) 1200 W09
NGC 4151(1) 6.396+0.006−0.006 (6.386 − 6.404) 21.7+3.3−4.1 (16.5 − 26.3) 190+29−36 (146 − 231) 2150+1220−680 (1250 − 3840) 6350 W09
NGC 4151(2) 6.391+0.004−0.004 (6.386 − 6.397) 18.2+2.7−2.5 (14.9 − 21.8) 78+11−11 (64 − 93) 2170+610−540 (1460 − 3000) ... ...
NGC 4151(3) 6.396+0.006−0.005 (6.389 − 6.404) 20.3+3.6−3.5 (15.7 − 25.3) 83+15−14 (64 − 103) 2670+790−680 (1760 − 3770) ... ...
NGC 4151(4) 6.400+0.006−0.005 (6.393 − 6.408) 11.5+2.9−2.6 (8.1 − 15.5) 188+47−43 (132 − 253) 1710+860−740 (690 − 2940) ... ...
NGC 4151(5) 6.393+0.016−0.008 (6.382 − 6.416) 14.3+8.3−4.2 (8.9 − 25.4) 57+33−17 (36 − 101) 2020+3600−870 (420 − 6750) ... ...
NGC 4151(total) 6.394+0.003−0.002 (6.391 − 6.398) 17.5+1.6−1.5 (15.5 − 19.7) 87+8−8 (77 − 98) 2250+400−360 (1770 − 2790) ... ...
3C 273(1) 6.336+0.074−0.053 (6.259 − 6.491) 5.9+5.0−4.0 (0.6 − 13) 35+29−24 (4 − 76) 5900+8640−5830 (0 − 80630) 3520 Z05
NGC 4593 6.406+0.011−0.042 (6.351 − 6.421) 3.8+3.4−1.4 (2.0 − 8.5) 82+74−30 (43 − 185) 2230+8180−1100 (670 − 15320) 3650 W09
MCG−6-30-15(1) 6.399+0.043−0.045 (6.335 − 6.461) 3.4+1.5−1.8 (1.0 − 6.1) 70+31−37 (21 − 125) 7440+5710−4630 (2480 − 16270) 1700 ± 170 N06
MCG−6-30-15(2) 6.395+0.061−0.044 (6.298 − 6.485) 1.9+1.4−0.9 (0.7 − 3.9) 40+30−19 (15 − 83) 2810+15450−1750 (0 − 23770) ... ...
MCG−6-30-15(3) 6.424+0.094−0.110 (6.237 − 6.557) 2.8+2.1−1.5 (0.8 − 5.7) 62+45−34 (17 − 124) 13590+12820−6050 (5760 − 37720) ... ...
MCG−6-30-15(4) 6.402+0.154−0.023 (6.364 − 6.602) 1.0+1.0−0.7 (0.1 − 2.3) 20+20−14 (2 − 45) <14800 (0 − 28590) ... ...
MCG−6-30-15(5) 6.345+0.027−0.024 (6.292 − 6.393) 2.2+2.3−1.4 (0.3 − 5.3) 46+48−29 (6 − 111) <5850 (0 − 15200) ... ...
MCG−6-30-15(total) 6.427+0.044−0.044 (6.366 − 6.486) 2.7+1.1−0.9 (1.5 − 4.1) 58+23−20 (32 − 88) 11880+4650−4030 (6480 − 18750) ... ...
IRAS 13349+2438(2) 6.396+0.046−0.057 0.7+0.5−0.4 (0.2 − 1.5) 170+139−93 (52 − 386) 5870+11370−2550 (2660 − 85550) ... ...
IRAS 13349+2438(total) 6.405+0.052−0.113 (6.106 − 6.841) 0.4+0.5−0.2 (0.07 − 2.3) 87+121−41 (16 − 532) 5150+60200−2810 (1770 − 93230) ... ...
IC 4329A 6.305+0.139−0.096 (6.172 − 6.542) 15.8+10.6−7.5 (5.9 − 31.5) 81+54−38 (30 − 162) 18830+18590−9620 (5820 − 48080) 5620 ± 200 N06
Mrk 279 6.414+0.054−0.028 (6.312 − 6.560) 2.0+1.2−0.9 (0.9 − 6.9) 132+80−59 (60 − 458) 5080+8390−1940 (2670 − 48780) 5150 W09
NGC 5506 6.400+0.007−0.006 (6.391 − 6.409) 7.1+1.6−2.1 (4.4 − 9.3) 84+18−25 (52 − 109) 1650+880−870 (470 − 2940) 1850 Z05
NGC 5548(1) 6.398+0.022−0.021 (6.367 − 6.427) 3.7+1.5−1.4 (1.9 − 5.8) 124+51−46 (64 − 195) 4410+2590−1580 (2390 − 8500) 5830 ± 230 N06
NGC 5548(2) 6.402+0.009−0.009 (6.389 − 6.415) 2.4+0.9−0.7 (1.4 − 3.6) 71+27−21 (42 − 107) 1960+1040−900 (800 − 3540) ... ...
NGC 5548(total) 6.403+0.009−0.009 (6.391 − 6.415) 2.7+0.8−0.7 (1.8 − 3.7) 84+25−22 (56 − 115) 2540+1140−820 (1490 − 4240) ... ...
Mrk 290(total) 6.404+0.037−0.038 (6.342 − 6.458) 1.0+0.6−0.5 (0.2 − 1.9) 60+33−31 (12 − 110) 5290+5120−2420 (2140 − 20200) 4740 W09
E1821+643 6.447+0.051−0.054 (6.355 − 6.517) 3.2+1.6−1.3 (1.6 − 5.4) 153+75−63 (76 − 257) 10920+7710−3910 (5640 − 25950) 6620 ± 720 N06
3C 382(2) 6.424+0.064−0.090 (6.254 − 6.531) 3.6+3.2−2.3 (0.7 − 8.1) 66+55−43 (13 − 144) 8100+12580−4490 (3150 − 33320) 8340 W09
3C 382(total) 6.418+0.084−0.097 (6.161 − 6.538) 3.4+2.3−2.5 (0.4 − 7.1) 57+39−42 (7 − 119) 10730+15810−8320 (2060 − 55310) ... ...
4C+74.26(total) 6.260+0.038−0.081 (6.125 − 6.392) 1.2+2.0−0.8 (0.1 − 4.1) 36+60−24 (3 − 124) <10980 (0 − 23620) 9420 W09
Mrk 509 6.428+0.020−0.021 (6.396 − 6.455) 3.6+2.0−1.7 (1.4 − 6.4) 57+30−27 (22 − 100) 2910+2590−1250 (1280 − 7900) 3430 ± 240 N06
NGC 7213(1) 6.392+0.013−0.011 (6.377 − 6.410) 2.9+1.1−1.0 (1.6 − 4.4) 117+46−40 (65 − 179) 2290+1950−1390 (390 − 5000) 3200 Z05
NGC 7213(2) 6.410+0.018−0.018 (6.384 − 6.436) 3.2+2.0−1.6 (1.2 − 6.0) 126+78−63 (47 − 236) 2400+2310−1800 (0 − 6770) ... ...
NGC 7213(total) 6.397+0.011−0.010 (6.384 − 6.412) 3.0+1.0−0.9 (1.8 − 4.3) 120+42−35 (73 − 174) 2590+1470−1170 (1050 − 4620) ... ...
NGC 7469(1) 6.385+0.010−0.012 (6.364 − 6.399) 3.2+1.1−1.2 (1.7 − 5.1) 116+42−42 (63 − 187) 1800+2640−1360 (0 − 6040) 2820 W09
NGC 7469(2) 6.395+0.036−0.033 (6.347 − 6.452) 3.9+2.0−1.6 (1.8 − 6.6) 156+79−64 (72 − 262) 6780+4810−3170 (3200 − 14100) ... ...
NGC 7469(total) 6.388+0.018−0.017 (6.365 − 6.413) 3.7+1.0−1.1 (2.2 − 5.2) 142+38−42 (84 − 199) 4890+2770−1700 (2740 − 8740) ... ...

Notes. Results from Chandra HEG data, fitted with a power law plus Gaussian emission-line model in the 2–7 keV band. Statistical errors are for the 68% confidence level, while parentheses show the 90% confidence level ranges of the parameters. aGaussian line center energy in keV. bEmission-line intensity in units of 10−5 photons cm−2 s−1. cEmission-line EW in units of eV. dFull width half maximum, rounded to 10 km s−1. eReferences for Hβ FWHM: L02, Lutz et al. (2002); M03, Marziani et al. (2003); M07, Moran et al. (2007); N06, Nandra (2006); P04, Peterson et al. (2004); W09, Wang et al. (2009); Z05, Zhou & Wang (2005). fBroad polarized Hβ line. gInfrared broad Brα line.

Download table as:  ASCIITypeset images: 1 2

The next selection criterion we used was more specifically focused on determining whether the model width was a measure of the true line width. Owing to the excellent spectral resolution of the HEG it is straightforward to determine when the model FWHM is no longer a measure of the Fe Kα emission-line width by reconciling the spectral data with the confidence contours of IFeKαversus the centroid energy, EFeKα. This can be seen in Figures 1 and 2 which show, for a given source, the rest-frame spectra in the Fe K region alongside the confidence contours of IFeKαversus EFeKα. We have not shown plots for all the data sets (spectra for all of the data sets can be found in the databases mentioned in Section 1). For example, we have not shown plots for data sets that have already been presented in YP04. Nor have we shown plots for data sets in which the detection of the Fe Kα line was marginal or insignificant. Figure 1 shows results for sources that have only one observation while Figure 2 shows time-averaged spectra for sources with multiple observations, alongside confidence contours for the individual and time-averaged data. We see in Figures 1 and 2 that in some cases the 99% confidence contours indicate a range in centroid energy that is clearly much larger than the breadth of the emission-line feature that can be estimated directly from the spectral plots. For example, for NGC 985 the joint, two-parameter, 99% confidence contour of line intensity versus center energy (solid line) is ∼600 eV wide. However, from the spectral plot in the Fe K band, the Fe Kα line clearly has a width less than ∼250 eV. Thus the 99% confidence bounds on line flux versus line centroid energy imply that the Gaussian component is in fact modeling the continuum, resulting in very large FWHM values that are not actually related to the physical width of the emission line. For this case of NGC 985, we constructed a 99% confidence contour (dotted line in Figure 1) of the line intensity versus energy with the Gaussian width fixed at 1 eV (110 km s−1). This shows that the centroid energy is constrained to be in the range ∼6.3–6.5 keV, consistent with the physical width of the narrow core in the spectral plot.

Figure 1.
Standard image High-resolution image
Figure 1.
Standard image High-resolution image
Figure 1.

Figure 1. Left panels: Chandra HEG spectra in the Fe K band for sources in which the Fe Kα emission line was detected in only one observation, and which were not included in the sample of Yaqoob & Padmanabhan (2004). The data are binned at 0.01 Å, comparable to the HEG spectral resolution, which is 0.012 Å FWHM. The data are combined from the −1 and +1 orders of the grating. The spectra have been corrected for instrumental effective area and cosmological redshift. Note that these are not unfolded spectra and are therefore independent of any model that is fitted. Although the spectral fitting was performed using XSPEC, the spectral plots were not made using XSPEC. The statistical errors shown correspond to the 1σ Poisson errors, which we calculated using Equations (7) and (14) in Gehrels (1986) that approximate the upper and lower errors, respectively. The solid line corresponds to a continuum model fitted over the 2–7 keV range (extrapolated to 7.5 keV), as described in the text (Section 3). The vertical dotted lines represent (from left to right) the rest energies of the following: Fe i Kα, Fe xxv forbidden, two intercombination lines of Fe xxv, Fe xxv resonance, Fe xxvi Lyα, Fe i Kβ, and the Fe K edge. Right panels: joint 99% confidence contours of the Fe Kα emission-line core intensity versus line centroid energy obtained from Gaussian fits to the line with the line width free as described in the text (solid lines). For Mrk 590, NGC 985, PG 0844+346(1) and IRAS 13349+2438(2), the 99% confidence contours (solid lines) of the were poorly constrained due to the intrinsic line width parameter becoming very large. Therefore, we overlaid the 99% confidence contours obtained with the line width fixed at 1 eV for these cases (dotted contours). For the remaining sources (ESO 198−G24, MCG−6-30-15(2), NGC 5506, and E1821+643), the dotted contours correspond to 68%, and 90% confidence.

Standard image High-resolution image
Figure 2.
Standard image High-resolution image
Figure 2.
Standard image High-resolution image
Figure 2.

Figure 2. Left panels: time-averaged Chandra HEG spectra in the Fe K band for eight AGNs in which the Fe Kα emission line was detected in more than one observation for cases that were not already reported in Yaqoob & Padmanabhan (2004). The data are binned at 0.01 Å except for NGC 4151, which is binned at 0.005 Å. The energies of the vertical dotted lines are described in the caption to Figure 1. Right panel: joint 99% confidence contours of the Fe Kα emission-line core intensity vs. line center energy for time-averaged and individual spectra. Individual observations are shown in different line styles while the time-averaged contours are shown with a solid line. The contour shown for Mrk 290 is from the time-averaged spectrum only, since none of the individual observations had sufficient signal-to-noise ratio to obtain well-constrained contours. For MCG−6-30-15, we show the contour from the time-averaged spectrum only, since only one of the four observations not reported in Yaqoob & Padmanabhan (2004) has a significant detection of narrow Fe Kα line, and that contour has already been shown in Figure 1.

Standard image High-resolution image

Table 3. Mean Fe Kα Line Spectral Parameters

Parameter By Observation No. of Spectraa By Source No. of Sourcesb
Centroid Energy (keV) 6.396 ± 0.0004c 68 6.397 ± 0.0005c 32
FeK fixed)        
Centroid Energy (keV) 6.388 ± 0.001 68 6.398 ± 0.002 32
FeK free)d        
EW (eV) 42 ± 2 70 44 ± 2 33
FeK fixed)        
EW (eV) 53 ± 3 70 70 ± 4 33
FeK free)d        
FWHM (km s−1) 2060 ± 230 53 2200 ± 220 27

Notes. Weighted mean quantities from spectral fitting to individual spectra ("by observation"), and to spectra representative of each source ("by source"); See Section 4 for details. aNumber of spectra (one per observation) contributing to the mean quantities. bNumber of unique sources contributing to the mean quantities. cThese statistical errors are smaller than the systematic errors (see Section 4.1 for discussion). dThe intrinsic width of the Fe Kα in these cases was free in the spectral fitting for 51 spectra in the individual observation fits (see Table 2) and for 27 sources in the fits to source-representative spectra (see Section 4 for details).

Download table as:  ASCIITypeset image

Thus, by comparing the line intensity versus line energy confidence contours with the spectra we determined that the FWHM constraints deduced from spectral fits for 16 out of the 65 data sets were not reliable indicators of the Fe Kα line core intrinsic width (none of the 16 are data sets summed over multiple observations). We found that the situations in which the Gaussian width model parameter became an unreliable indicator of the emission-line intrinsic width generally corresponded to a 90% confidence, two-parameter upper limit on the FWHM greater than ∼15, 000 km s−1. We note that even for the cases where we can obtain a reliable measure of the Fe Kα line FWHM, the true line width may be less than the FWHM deduced from our simplistic model-fitting because there may be blending from an unresolved Compton-shoulder component and/or from several (low) ionization states of Fe. Also, the difference in rest energy of ∼13 eV of the individual components of the Fe Kα line (Kα1 and Kα2) may increase the apparent FWHM if the line is modeled with a single Gaussian model component. However, the separation of Kα1 and Kα2 corresponds to ∼600 km s−1 (three times less than the HEG resolution in the Fe K band), and considering the Kα1:Kα2 branching ratio of 2:1, Yaqoob et al. (2001) showed that artificial broadening is not a concern for line parameters and signal-to-noise ratio that are typical of the HEG observations reported here.

In the present paper we are concerned only with the Fe Kα line core centered at ∼6.4 keV, and not emission lines from highly ionized species of Fe. Nevertheless, overlaid on the spectra in Figure 1 are vertical dashed lines marking the positions of the Fe xxv He-like triplet lines (the two intercombination lines are shown separately), Fe xxvi Lyα, Fe i Kβ, and the Fe K-shell threshold absorption-edge energy. The values adopted for these energies were from NIST4 (He-like triplet); Pike et al. 1996 (Fe xxvi Lyα); Palmeri et al. 2003 (Fe i Kβ), and Verner et al. 1996 (Fe K edge). Emission lines and absorption lines from highly ionized species of Fe have indeed been reported in the literature for some of the same data sets discussed in the present paper (e.g., see Bianchi et al. 2005). We summarize such results from the literature in the appendix for each source as appropriate, including any previous results on the 6.4 keV emission line that are based on the same data that we have employed. We also give in the appendix any unusual details and/or issues for particular data sets that are pertinent to our analysis of the HETGS data.

4. PROPERTIES OF THE CORE OF THE Fe Kα LINE EMISSION

Table 3 summarizes various mean quantities from the Fe Kα line measurements, calculated in two different ways. In the first method we used the measurements from individual observations and in the second method we used measurements that are representative of properties per source. For the latter, in most cases this utilized measurements from spectra averaged over multiple observations where relevant, except for NGC 526, PG 0834, 3C 273, IRAS 13349+2438, and 3C 382. For these five sources, the Fe Kα line was significantly detected in only one observation and combining observations led to looser constraints on the Fe Kα line parameters, as previously explained in Section 3. Thus we used only the one observation for these five sources that showed the best detection of the Fe Kα line. This may bias the results because we do not know if non-detections of the Fe Kα are due to variability. We caution that any sample properties derived using our results should take account of such possible biases. We also caution that the Chandra grating sample is subject to very peculiar and unquantifiable selection effects because of the restrictions on the kind of sources that are suitable for observations with gratings (or more precisely, which sources proposal review panels judge to be suitable for observations with gratings). Thus, the Chandra grating AGN archive is not suitable for unbiased population studies. The principal purpose of the present work is to systematically quantify the spectral parameters from the data.

4.1. Line Centroid Energy

From our analysis, we were able to measure the Fe Kα line centroid energy in 32 out of 36 unique sources for at least one spectrum (see Tables 1 and 2). Table 3 summarizes four different weighted mean line centroid energies. One pair of measurements was derived from individual observations and the other pair was derived from per source measurements (as described above). Each mean centroid energy was derived from spectral-fitting results in which the intrinsic line width was fixed (Table 1), and from results in which the intrinsic line width was not fixed in all the spectra (Table 2). Here, and hereafter, for the calculation of the weighted mean of any quantity with asymmetric errors, we simply assumed symmetric errors, using the largest 68% confidence error from spectral fitting. For the line centroid values, 68 out of 82 spectra contributed to the "per observation" means, and 32 sources contributed to the "per source" means. It can be seen from Table 3 that all four mean line centroid energies are within −12 eV and +3 eV of 6.400 keV (including statistical bounds).

Note that the statistical errors on the mean centroid energies are 1 eV or better but they may be biased by the brightest sources and largest exposure times. A more useful measure of the dispersion in the line energies may be gleaned from examining the distribution of energies. Figure 3 shows histograms of the Fe Kα line centroid energy. Again, we show four histograms: Figures 3(a) and (c) pertain to "per observation" results and Figures 3(b) and (d) pertain to "per source" results. Figures 3(a) and (b) pertain to Fe Kα line centroid energies measured with the intrinsic line width fixed (Table 1), and Figures 3(c) and (d) pertain to results obtained when the intrinsic line width was not fixed in all the observations (Table 2). The dashed and dotted lines correspond to histograms made from the 68% confidence lower and upper limits on the line centroid energy, respectively. The fits in which the Fe Kα line width was fixed gave line centroid energies that are more reliable indicators of the peak line energy because the fits with the line width free are more prone to the centroid energy being affected by the shape of the line profile. All panels show that the histograms are not Gaussian but sharply peaked at ∼6.4 keV. There is not a significant difference between the "per observation" and "per source" distributions, within the statistical errors. For the "per observation" fits with the Fe Kα line width fixed, we found that ∼80% of the best-fitting line centroid energies lie in the range 6.38–6.43 keV, a spread of only 50 eV. Another way of expressing our results is that if we take the highest signal-to-noise measurement for each source (i.e., utilizing results from the summed spectra only, for sources with multiple observations), we find that 21 out of 32 sources (∼66%) have 68% confidence statistical bounds on the line centroid energy that lie entirely in the range 6.38–6.43 keV. A similar procedure also shows that 30 out of 32 sources (∼94%) have 68% confidence bounds on the line centroid energy that lie entirely in the range 6.35–6.47 keV. We note that we might have expected to observe additional peaks in the centroid energy distribution blueward of 6.4 keV due to highly ionized Fe. Although such emission lines have been detected in HEG data (e.g., NGC 7314, Yaqoob et al. 2003; NGC 7213, Bianchi et al. 2008), the HEG effective area is already very small at 6.4 keV (only ∼20 cm−2) and drops very rapidly at higher energies. Higher throughput detectors such as those aboard XMM-Newton or Suzaku are more suitable for investigating the frequency of occurrence of highly ionized Fe emission lines.

Figure 3.

Figure 3. Distributions of Fe Kα line core centroid energies constructed in four different ways. (a) and (b) were made using the results from individual observations, whereas (c) and (d) were made from measurements that used spectra averaged from multiple observations of a given source where relevant (see Section 4 for exceptions). In (a) and (c), the line intrinsic width was fixed at 1 eV (results from Table 1). In (b) and (d), the line centroid energies that could be measured with the line width free were utilized (i.e., those from Table 2), keeping the line measurements from Table 1 for the remainder. For the individual observations this results in 51 out of 68 values being obtained with the line width free (see the text for details). The dashed and dotted lines in each case correspond to the distribution of 68% confidence lower and upper limits on the line centroid energy, respectively.

Standard image High-resolution image

We now examine those measurements that deviate significantly from the 6.4 keV peak of the Fe Kα line centroid energy distribution in Figure 3. For 3C 273 and 4C 74.26, we obtained Fe Kα line centroid energies lower than those for the bulk of the measurements, and we note that even the 90% confidence upper limits were less than 6.4 keV for the fits in which the line width was fixed (see Table 1). For the fits in which the line width was free, the corresponding upper limits were 6.49 keV and 6.39 keV for 3C 273 and 4C 74.26, respectively (see Table 2). However, for these two sources, the detection of the Fe Kα line was marginal: C decreased by less than 9.3 when a narrow Gaussian was added to a power-law continuum-only model. Thus, the lines were detected with only 99% confidence or less. Such low centroid energies are not unphysical. For example, they could be affected by gravitational redshifts. We note that a weak broad Fe Kα line has been detected in 3C 273 by XMM-Newton (Page et al. 2004a) and the 99% confidence contour does not rule a line with a centroid energy in the range ∼ 6.2–6.3 keV. Interestingly, a narrow component of the Fe Kα line at 6.2 keV, in addition to an Fe Kα line at ∼6.4 keV, has been detected in 4C 74.26 by XMM-Newton (Ballantyne & Fabian 2005).

For PG 0844+346, we obtained a centroid energy for the Fe Kα line consistent with 6.4 keV from the fits with the line width fixed (see Table 1). However, allowing the line width to float gave a centroid energy of ∼6.6 keV, with a 90% confidence lower limit of 6.42 keV (see Table 2). The reason for this apparently discrepant behavior is clear from the spectrum of PG 0844+346 in Figure 1. The spectrum shows an emission line centered at ∼6.4 keV and this is picked up in the fits for which the line width was fixed (the measured energy was 6.364+0.007−0.009 keV). The spectrum also shows two additional peaks at higher energies, albeit with a low signal-to-noise ratio. Allowing the single-line Gaussian model width to be free in the fits then causes the line component to model all three narrow lines by broadening the Gaussian.

In summary, we measured the centroid energy of the Fe Kα emission line in 32 out of 36 sources. In 30 out of the 32 sources, the line centroid energy lies in the range 6.35–6.47 keV, inclusive of the 68% confidence statistical errors. We note that ionization states less than Fe xvii correspond to Fe Kα line energies lees than 6.43 keV (e.g., Palmeri et al. 2003; Mendoza et al. 2004). When individual sources among the 30 are considered, the line centroid energy can constrain the ionization state to be much lower than Fe xvii in some cases. In the remaining two sources, 3C 273 and 4C 74.26, the line centroid energy, including statistical errors, appears to be lower than 6.4 keV, but the detection is marginal in these two sources.

4.2. Line Equivalent Width

From the spectral-fitting results for which the Fe Kα line intrinsic width was fixed (Table 1), 33 of the 36 sources have at least one spectrum from which we could measure the EW with a non-zero 90% confidence lower limit and a finite upper limit. The three sources for which only upper limits on the EW could be obtained were Mkn 705, PDS 456, and IRAS 18325 − 5926. In total, 70 out of 82 of the individual observations in Table 1 yielded bounded lower and upper limits on the EW. We calculated weighted mean EW values in four different ways (as we did for the line centroid energy in Section 4.1): i.e., from "per observation" and "per source" values, each set obtained with the intrinsic line width fixed in all spectral fits (Table 1) and with the intrinsic line width free in some of the spectra (Table 2). The resulting mean EW values are summarized in Table 3. It can be seen that the mean Fe Kα EW is somewhat sensitive to how it is calculated, ranging from 42 eV to 70 eV, with a statistical error of 4 eV or less. We note, however, that a value of ∼40 eV could be interpreted as a fairly robust sample lower limit on the EW of any unresolved core of the Fe Kα line.

Figure 4 shows histograms of the Fe Kα line EW, again constructed in four different ways. Figures 4(a) and (c) pertain to "per observation" results and Figures 4(b) and (d) pertain to "per source" results. Figures 4(a) and (b) pertain to Fe Kα line EWs measured with the intrinsic line width fixed (Table 1), and Figures 4(c) and (d) pertain to results obtained when the intrinsic line width was not fixed in all the observations (Table 2).

Figure 4.

Figure 4. Distributions of Fe Kα line EW constructed in four different ways. (a) and (b) were made using the results from individual observations, whereas (c) and (d) were made from measurements that used spectra averaged from multiple observations of a given source where relevant (see Section 4 for exceptions). In (a) and (c), the line intrinsic width was fixed at 1 eV (results from Table 1). In (b) and (d), the line centroid energies that could be measured with the line width free were utilized (i.e., those from Table 2), keeping the line measurements from Table 1 for the remainder. For the individual observations this resulted in 70 out of 82 values being obtained with the line width free (see the text for details). The dashed and dotted lines in each case correspond to the distribution of 68% confidence lower and upper limits on the line EW, respectively. The shaded histograms in both panels mark the 68% upper limits on the EW for 12 observations in which the EW could not be measured. Note that the largest EW of ∼600 eV (for PG 0844+349) is not shown in (b) and (d) because it is not a true measure of the narrow-line EW at ∼6.4 keV (see the text).

Standard image High-resolution image

The dashed and dotted histograms in Figure 4 correspond to the distributions of the 68% confidence lower and upper limits on EW, respectively. The shaded histograms in both panels are the 68% upper limits on the EW for the 12 observations in which the EW could not be measured. For the "per observation" and intrinsic line width fixed results, Table 1 and Figure 4(a) show that the maximum best-fitting EW of the Fe Kα line core is 162 eV, and >90% of the measurements have a best-fitting EW less than 100 eV. We also found that 79% of the measurements have a 68% confidence upper limit on the EW of less than 100 eV (23 unique sources). Including the results from the fits with the Fe Kα line width free, we found that ∼70% of the "per observation" measurements have a best-fitting equivalent EW less than 100 eV (Figure 4(c)). Within the statistical errors, the histograms obtained from the "per observation" results are not significantly different to the corresponding "per source" histograms. Note that in Figures 4(c) and (d), we do not show the measurement for PG 0844+346, as its EW is artificially high (∼ 600 eV) because it is not a true measure of the EW of the emission line at ∼6.4 keV (see Section 3).

From a theoretical point of view, the Fe Kα line EW depends on a number of factors, including geometry, orientation, column density, and covering factor of the line-emitting matter distribution, as well as element abundances. Time delays between variations in the continuum level and the Fe Kα line flux also affect the EW measured during a given observation. The sample EW results should therefore be interpreted in terms of a particular geometry. The relatively small dispersion of the EW distribution that we measure from the HEG data translates into a small dispersion in the parameters mentioned above, but it is difficult to uniquely constrain these parameters from the EW distribution due to degeneracy. In the context of the toroidal X-ray reprocessor model of MY09, which subtends a solid angle of 2π at the X-ray source, the measured EW distribution is consistent with the MY09 model if the mean of the EW distribution corresponds to column densities greater than ∼2 × 1023 cm−2 (see MY09). This column density does not refer to the line-of-sight value, but rather to the angle average over all incident X-ray continuum radiation. Comparison of the HEG results with the toroidal reprocessor models of Ghisellini et al. (1994) and Ikeda et al. (2009) leads to similar conclusions. The upper bound on the column density is not constrained because, for situations in which the Fe Kα line is observed for lines of sight that intercept a column density <1023 cm−2, the EW attains a maximum for an angle-averaged column density of ∼1024 cm−2, above which the EW decreases again as the line emitter becomes Compton-thick (e.g., se MY09). Increasing the covering factor of the reprocessor can increase the EW of the Fe Kα line observed in reflection but there is a trade-off because as the covering factor approaches unity, the projected area of the reflection region decreases and emission-line photons are more prone to being impeded from escaping the medium. Ikeda et al. (2009) found that the EW is greatest for covering factors of ∼0.7–0.9 but does not exceed ∼180 eV in their model for cosmic abundances and a power-law photon index of 1.9. In principle, the shape and relative magnitude of the Fe Kα line Compton shoulder could determine whether the reprocessor is Compton-thin or Compton-thick but this is challenging due to the limited signal-to-noise ratio of the data and also requires more sophisticated modeling. Such an investigation will be reported in future work. So far, all analyses with respect to the Compton shoulder and HEG AGN data have employed ad hoc models (e.g., Kaspi et al. 2002; Yaqoob et al. 2005) so they do not yield a meaningful physical interpretation.

4.3. Intrinsic Line Width

The location of the medium responsible for the core of the Fe Kα emission line can potentially be constrained by the measurements of the line intrinsic width. The weighted mean FWHM of the Fe Kα line cores for the 53 individual data sets (27 unique sources) for which it could be measured (Table 2), is 2060 ± 230 km s−1. This includes the two sources (Mrk 290 and 4C 74.26) for which the Fe Kα line FWHM could only be constrained from the summed spectra. We also calculated the weighted mean FWHM from "per source" measurements and found a similar value of 2200 ± 220 km s−1 (see Table 3).

In Table 2 are values of the Hβ FWHM compiled from the literature. Comparing the Fe Kα line FWHM with that of the Hβ line can potentially give a direct indication of the location of the Fe Kα line-emitting region relative to the optical broad-line region (BLR). A direct comparison of the Fe Kα line width with optical BLR line widths was not attempted in YP04 because the number of sources with sufficiently high quality Fe Kα line-width measurements was too small. Nevertheless, Nandra (2006) using the YP04 results, supplemented by a few other HEG measurements from the literature, examined the relation between the FWHM of Fe Kα and Hβ. The results were ambiguous, the data allowing for an origin of the Fe Kα line anywhere from the BLR to parsec-scale distances from the putative central black hole. Moreover, some of the HEG measurements for the Fe Kα line FWHM compiled from the literature were problematic. For example, for MR 2251 − 178, Gibson et al. (2005) reported an upper limit on the Fe Kα line FWHM of 1530 km s−1 and Nandra (2006) erroneously quoted and used as 650 km s−1 (Gibson et al. 2005 reported a σ of 650 km s−1, not FWHM). In our uniform analysis, we found that the HEG data for MR 2251 − 178 were so poor that a meaningful upper limit on the Fe Kα FWHM cannot even be measured and therefore we have reported only results for a fit with the line width fixed at well below the HEG resolution (Table 1).

A notable example for which a meaningful comparison between the Fe Kα and Hβ line widths has been reported using HEG data is NGC 7213 (Bianchi et al. 2008). In this case the FWHM of both lines are consistent with each other (∼2500 km s−1), implying an origin of the Fe Kα line in the BLR for NGC 7213. Our sample includes NGC 7213 and our analysis (see Table 2) confirms the results of Bianchi et al. (2008). Utilizing all of the results from our uniform analysis of the HEG sample for which the Fe Kα line width could be at least loosely constrained (Table 2), we have plotted in Figure 5 the Fe Kα line FWHM against the Hβ FWHM. The dashed line corresponds to the two line widths being equal. The statistical errors shown correspond to 68% confidence. We have distinguished 12 sources in Figure 5 by empty circles (as opposed to filled circles) that provide the very best statistical constraints on the Fe Kα line FWHM in our sample. The next best measurement of the FWHM would be NGC 985, but we note that its 99% two-parameter confidence contour for Fe Kα line flux versus FWHM did not close before the Gaussian component began to model the continuum. In Figure 5, points that lie above the dashed line at some level of confidence mean that an origin in the BLR of at least part of the Fe Kα line is not ruled out, but contributions from further out than the BLR are not ruled out either (at the appropriate level of confidence). A larger FWHM for the Fe Kα line compared to the Hβ line could either mean a genuine contribution to the Fe Kα line from matter closer to the central black hole than the BLR, or it could mean that there is a contribution from an unresolved Compton shoulder or from part of a broader disk line. Points that lie below the dashed line in Figure 5 at some level of confidence place stronger constraints on the origin of the narrow Fe Kα line because in that case, whatever physical sources of broadening are affecting the Fe Kα line, it must originate in a region that lies further from the central black hole than BLR.

Figure 5.

Figure 5. Fe Kα emission-line FWHM vs. the Hβ FWHM for which the Fe Kα line width could be constrained (see the text and Table 2). For MCG−5-23-16, we used the FWHM of infrared broad Brα line as a surrogate for Hβ FWHM. The dashed line corresponds to the two line widths being equal. Open circles correspond to the 12 cases shown in Figure 6, for which the best Fe Kα line FWHM constraints were obtained (see the text). The statistical errors on the Fe Kα line FWHM shown correspond to 68% confidence for three free parameters.

Standard image High-resolution image

Standard tests for assessing the significance of any possible correlation between FWHM(Fe Kα) and FWHM(Hβ), such as the Spearman Rank correlation coefficient, are problematic because they do not take account of measurement errors on FWHM(Fe Kα), which can be large. Assessing the effect of measurement errors on such correlation coefficients properly requires extensive and realistic simulations of the data and the spectral-fitting process. Instead, we used the χ2 statistic to fit a straight line to the FWHM values of the Fe Kα and Hβ lines. Although we are forced to assume a relationship between the two quantities, any correlation would still manifest itself. In the fitting we explicitly took into account the statistical errors on the Fe Kα line widths, using the average of the 68% confidence upper and lower errors. We found that FWHM(Fe Kα) = (0.04 ±  0.13)× FWHM(Hβ) + (2130 ±  550), with χ2 = 17.1 for 21 degrees of freedom. The reduced χ2 value <1 then means that indeed a more complicated model is not warranted. More importantly, we see that even the 1σ errors on the slope include a slope value of zero (corresponding to the case that all the FWHM values are consistent with a constant, independent of the FWHM of the Hβ line). Therefore, we find no evidence of a correlation between the Fe Kα and Hβ line widths, consistent with the conclusion of Nandra (2006). However, Nandra (2006) interpreted the lack of a correlation in terms of the narrow Fe Kα line not originating in the BLR, but we now know that in some cases this is not true (e.g., NGC 7213, Bianchi et al. 2008). We shall see below that our results in fact show that the location of the Fe Kα line emitter relative to the BLR appears to be genuinely different from source to source.

From our spectral fits to the subset of HEG data with the Fe Kα line width free (Table 2) we constructed joint 68%, 90%, 99% confidence contours of the Fe Kα line EW versus the ratio of the Fe Kα FWHM to the Hβ FWHM. These are shown in Figure 6 and a variety of behavior is displayed. We found cases in which this FWHM ratio was, at the two-parameter 99% confidence level, less than 1 (NGC 3783, NGC 4151, and NGC 5548), greater than 1 (MCG−6-30-15), or consistent with 1 (3C 120, NGC 2110, MCG−5-23-16, NGC 3516, NGC 5506, Mrk 509, NGC 7213, and NGC 7469). Thus, it appears that the location of the Fe Kα line relative to the location of the Hβ line-emitting region may be different from source to source. For our limited-sized sample the Fe Kα line-emitting region size could be up to a factor ∼5 larger than the Hβ line-emitting region (NGC 4151, see Figure 6). We note that the putative parsec-scale obscuring torus that is required by AGN unification schemes, and that has always been a strong contender for any Fe Kα line emission beyond the BLR, may be smaller than traditionally thought. In particular, Gaskell et al. (2008) argue that there is considerable observational evidence that the BLR itself has a toroidal structure, and that there may be no distinct boundary between the BLR and the classical parsec-scale torus. Our results from the Chandra HEG data do not conflict with such a scenario.

Figure 6.
Standard image High-resolution image
Figure 6.

Figure 6. Joint 68%, 90%, and 99%, confidence contours of the Fe Kα emission-line core EW vs. the ratio of the Fe Kα FWHM to the Hβ FWHM for 12 AGNs that provided the best measurements of Fe Kα line FWHM (see the text). For MCG−5-23-16, we used the FWHM of infrared broad Brα line as a surrogate for Hβ FWHM. The vertical dotted lines correspond to an FWHM ratio of the pairs of emission lines equal to unity.

Standard image High-resolution image

From joint confidence contours of Fe Kα line intensity versus FWHM we can determine whether the line is resolved from a given data set if the contour (at some level of confidence) does not cross the FWHM = 0 axis. We found that at 99% confidence (two parameters), the Chandra HEG resolves the narrow component of the Fe Kα emission in 15 sources, namely, F9, NGC 2110, MCG−5-23-16, NGC 3516, NGC 3783, NGC 4051, NGC 4151, MCG−6-30-15, IRAS 13349+2438, IC 4329A, Mrk 279, NGC 5548, E1821+643, NGC 7469, and NGC 7213. We do not include PG 0834+346 here, since the single-Gaussian fit with the line width free does not pick up the narrow component at ∼ 6.4 keV (see Section 3). We caution that in general an emission line that is resolved by the HEG may indicate complexity as opposed to a simple, single emission line.

4.4. Line Flux

If the Fe Kα line originates in a matter distribution whose light-crossing time is much greater than the typical timescale of variability of the X-ray continuum, the variability of the line flux will be suppressed. The line flux may then even be constant (within statistical errors) and correspond to some historically averaged continuum level. The sources in our HEG sample that have multiple observations enable us to investigate the time dependence of the Fe Kα line flux. The spectral resolution of the HEG currently allows the best isolation of the narrow Fe Kα line for the largest sample compared to previous studies. In Figure 2, we showed the Fe Kα line intensity versus centroid energy 99%, two-parameter confidence contours for each source that has multiple observations. The contours for NGC 3783 were shown in Yaqoob et al. (2005) and are not shown again in Figure 2. In no source did we find evidence for variability of the Fe Kα line flux at 99% confidence or greater. However, it is important to note that the 99% confidence regions in some cases cover a large range in line flux due to limited signal-to-noise ratio. However, we can say that in our HEG sample, the data are consistent with no variability of the Fe Kα line but more sensitive instrumentation is required to reduce the statistical errors.

5. X-RAY BALDWIN EFFECT

The so-called X-ray Baldwin effect, a possible anti-correlation between the Fe Kα line EW and X-ray luminosity, has been discussed at length in the literature (e.g., Iwasawa & Taniguchi 1993; Nandra et al. 1997; Page et al. 2004b; Jiang et al. 2006; Bianchi et al. 2007; Winter et al. 2009). These studies have found some evidence for an X-ray Baldwin effect albeit with significant scatter, but the latter two studies have found that the Fe Kα line EW appears to be more strongly anti-correlated with the ratio of X-ray luminosity to Eddington luminosity (Lx/LEdd, a proxy for the accretion rate). However, Winter et al. (2009) found that the X-ray Baldwin effect was only significant if the EW and Lx/LEDD values were binned, and the formal significance of the anti-correlation depended strongly on the details of the binning procedure. Except for some HETGS data used by Jiang et al. (2006), all other studies of the X-ray Baldwin effect to date have been based on data that have a spectral resolution of ∼7000 km s−1 FWHM or worse. Therefore, it is not clear whether the Fe Kα line parameters in these studies correspond to contributions from line emission blended from completely different origins (e.g., distant-matter and accretion-disk components). Using our sample that consists only of HEG data, we can investigate the X-ray Baldwin effect with a spectral resolution in the Fe K band that is nearly four times better than in previous studies, and therefore provide the best isolation of the narrow core that is possible with current instrumentation.

For this purpose we used our spectral-fitting results obtained with the Fe Kα line width fixed at 1 eV, well below the HEG resolution, in order to obtain a uniform set of Fe Kα line EW measurements for the largest number of sources (see Table 1). We examined correlations using both the "per observation" results and the "per source" results. Measurements for the latter were derived from only one spectrum per source, which in some cases was the average spectrum, as described in Section 4. These values of EW are plotted against Lx in Figures 7(a) and (c), and against Lx/LEDD in Figures 7(b) and (d). Note that in Figure 7 we have shown all EW measurements whether or not they are only upper limits, even though upper limits will not be used in the quantitative analysis. The Eddington luminosity, LEdd, is computed from MBH × 1.3 × 1038 erg s−1, where MBH is the mass of the central black hole. Values of MBH are from Zhou & Wang (2005), Bianchi et al. (2007), and Wang et al. (2009). As a proxy for the accretion rate we use the ratio of L2–10 keV/LEdd (see, e.g., Vasudevan & Fabian 2009 for the correspondence between and X-ray luminosity and bolometric luminosity). We were not able to find reliable mass estimates for Mrk 705 and IRAS 18325 − 5926 so these sources were excluded from any analyses involving LEdd. The statistical errors shown in Figure 7 are 68% confidence for two free (Gaussian) parameters. It can be seen that, despite better isolation of the Fe Kα line core, there is still significant scatter in the diagrams.

Figure 7.

Figure 7. (a) Fe Kα core emission-line EW vs. the 2–10 keV luminosity. (b) As (a) for EW vs. (L2–10 keV/LEdd), a proxy for the accretion rate. Both (a) and (b) were constructed from measurements made from individual observations. (c) As (a) but showing EW vs. L2–10 keV for measurements made from spectra combining multiple observations for a given source, where relevant. (d) As (c) but showing EW vs. (L2–10 keV/LEdd). In (c) and (d) the average spectrum was not used for all sources, for (b) and (d) reliable black hole mass estimates were not available for all sources (see Sections 4 and 5 for details). All of the measurements shown in (a)–(d) utilize results from the spectral fitting in which the Fe Kα line intrinsic width was fixed at 1 eV. The statistical errors on the Fe Kα line EW correspond to 68% confidence. The dotted lines show the correlations obtained by linear fits to log EW vs. log L2–10 keV (a) and (c), and log EW vs. log(L2–10 keV/LEdd) (b) and (d). Note that observations with only upper limits on the EW were not included in the fits.

Standard image High-resolution image

In order to formally assess the significance of any correlation, standard methods that do not take account of the statistical errors on the EW, such as the Spearman Rank correlation coefficient are problematic. This is because, in the type of analysis presented here, and in previous works on the X-ray Baldwin effect, the actual best-fitting values of EW are not in themselves meaningful. It is the statistical errors on the EW that are the important quantities. Assessing the effect of measurement errors on such correlation coefficients properly requires extensive and realistic simulations of the data and the spectral-fitting process. On the other hand, the χ2 statistic does take account of the statistical errors on the EW. Although we are forced to assume a form of the relationship between the EW and Lx if we use χ2, it can be seen from Figure 7 that the quality of the data does not support constraining a more complex relationship. We therefore fitted a straight line to log EW versus log Lx using the χ2 fit statistic (i.e., a power-law function for EW versus Lx). Data points that only had upper limits on the EW were not included. In the fitting we took into account the statistical errors on the EW, using the average of the 68% confidence upper and lower errors.

The results of the χ2 analysis are shown in Table 4. For each of the four cases ("per observation," "per source," and EW versus Lx or Lx/LEdd) we show the best-fitting value of χ2, the intercept and slope of the best-fitting line, as well as the 68% confidence and 99% confidence one-parameter errors on the slope. The latter error bounds were determined by varying the slope, while allowing the intercept to float, and determining the bounds on the slope for Δχ2 = 0.989 and 6.635 for 68% and 99% confidence, respectively. If the EW is indeed anti-correlated with either Lx or Lx/LEdd we would expect that the slope of the line is significantly different from zero. Therefore, in Table 4 we also show values of Δχ2 obtained when the slope is forced to be zero, as well as the corresponding significance that the slope is non-zero. We found that the "per observation" results gave a stronger anti-correlation than the "per source" results, for both the EW versus Lx and EW versus Lx/LEdd relations. Quantitatively, the "per observation" results show a significance of 6.05–6.27σ for a non-zero slope, as opposed to ∼3.08–3.24σ for the "per source" results. The best-fitting slopes for the latter are about half of the corresponding values of the "per observation" results. We caution that the absolute significance values should not be interpreted literally since we do not know the form of the functional relationship between EW and Lx. Table 4 also shows that there is no significant difference in the χ2 analysis results whether we examine the relation of EW between Lx or Lx/LEdd, and that is true whether we consider the "per observation" or "per source" results. Both our "per observation" and "per source" results for the slope of the EW versus Lx relation are formally consistent, within the uncertainties, with that found by Page et al. (2004b) who reported EW ∝L−0.17 ± 0.08). In addition, our results for the slope of the relation between EW and Lx/LEdd are formally consistent with that obtained by Bianchi et al. (2007) (EW ∝ (Lbol/LEdd)−0.19 ± 0.05). We note that the latter study of Bianchi et al. (2007) excluded sources with high radio loudness and still found a significant Baldwin effect.

Our results seem to confirm the X-ray Baldwin effect. There are several factors that could produce an anti-correlation of the EW of the Fe Kα line and the intrinsic X-ray continuum luminosity. A decrease of covering factor and/or the column density of line emitting with increasing X-ray continuum luminosity likely are the most important factors. Another possibility is that the line-emitting material becomes more and more ionized as the X-ray luminosity increases, leaving less low-ionization material to produce the Fe Kα line at ∼6.4 keV. Unfortunately the data cannot yet distinguish between these scenarios. A complete understanding of the Baldwin effect should also take into consideration the fact that the Fe Kα line EW in individual sources can vary by more than a factor of 2 (if the line intensity does not respond to large-amplitude continuum variations), although simulations based on the simplest assumptions yield an anti-correlation between EW and continuum luminosity weaker than observed ones and with a large scattering (EW∝L−0.05 ± 0.05; Jiang et al. 2006).

Table 4. X-ray Baldwin Effect: Fe Kα Line EW versus Luminosity Fits

Parameter By Observation By Source
log EW = kL + [mLlog(Lx)]    
χ2 (d.o.f.) 58.5(68) 24.7(31)
Intercept, kL 1.80+0.02−0.02 1.76+0.02−0.02
Slope, mL (68% confidence errors) −0.22+0.03−0.03 −0.13+0.04−0.04
Slope, mL (99% confidence errors) −0.22+0.10−0.07 −0.13+0.11−0.11
Δχ2 for mL = 0 39.3 10.0
Significance for mL ≠ 0 6.27σ 3.24σ
log EW = kR + [mRlog(Lx/LEDD)]    
χ2 (d.o.f.) 61.4 (68) 25.2(31)
Intercept, kR (68% confidence errors) 1.31+0.09−0.09 1.50+0.09−0.09
Slope, mR (68% confidence errors) −0.20+0.03−0.03 −0.11+0.04−0.04
Slope, mR (99% confidence errors) −0.20+0.07−0.11 −0.11+0.09−0.09
Δχ2 for mR = 0 36.6 9.5
Significance for mR ≠ 0 6.05σ 3.08σ

Notes. Results of fitting the relations between the derived Fe Kα line EWs and the 2–10 keV X-ray luminosity (Lx), and between the EWs and the Eddington ratio (Lx/LEDD). Coefficients and their error bounds are shown for linear fits to log EW vs. log(Lx), and to log EW vs. log(Lx/LEDD) for spectral-fitting results to the individual spectra ("by observation"), and to the source-representative spectra (see Section 5 for details). The number of degrees of freedom for each fit (d.o.f.) is shown in parentheses after each best-fitting χ2 value.

Download table as:  ASCIITypeset image

6. SUMMARY

We have presented an empirical and uniform analysis of the narrow core of the Fe Kα emission line in a sample of 82 observations of 36 AGNs with low to moderately low X-ray absorption (NH < 1023 cm−2), using Chandra HEG data. The Fe Kα line was detected in 33 sources, and its centroid energy was measured in 32 sources (68 observations). The distribution in the centroid energy is strongly peaked around ∼6.4 keV, with over 80% of the measurements lying in the range 6.38–6.43 keV. Including the statistical errors and utilizing the best measurements for each source, the line centroid energy lies entirely in the range 6.35–6.47 keV for 30 out of 32 sources. Thus we confirm, for the largest sample of AGN observed with such a high spectral resolution (FWHM ∼1860 km s−1 at 6.4 keV), the ubiquity of the narrow core of Fe Kα line, and its preferred origin in cool, neutral, or only mildly ionized matter.

The EW of the core of the Fe Kα line was constrained in 70 out of 82 observations, with only upper limits obtained from the remaining 12 spectra. The weighted mean EW was 53 ± 3 eV, and ∼70% of the individual measurements had a 68% confidence upper limit on the EW of less than 100 eV. Similar results were obtained when considering the EW distribution by source, although the weighted mean was somewhat higher from measurements that allowed the intrinsic line width to be free (70 ± 4 eV). The EW distribution can be produced by both Compton-thin and Compton-thick matter distributions and a more detailed analysis with a physical model is required to distinguish between the two scenarios. We also presented measurements of the flux of the core of the Fe Kα line and found that for sources that had multiple observations, there was no case in which the line flux varied between observations, within the statistical errors.

The intrinsic width of the core of the Fe Kα line was measured for 27 sources (53 observations) and we obtained a weighted mean value of FWHM = 2060 ± 230 km s−1 (or = 2200 ± 220 km s−1 when considering measurements by source, not by observation). Of the 27 sources, 12 yielded 99% confidence, two-parameter contours of line flux versus FWHM that were good enough to investigate the relation between the width of the Fe Kα line and the width of the Hβ line (or Brα for one of the sources). We found that the ratio of the X-ray to optical line width varies from source to source. The 99% confidence, two-parameter upper limit lies in the range ∼0.5–4 for the 12 sources. This means that contributions to the flux of the core of the Fe Kα line are allowed down to a factor ∼0.7–2 times the radius of the optical BLR. The upper limit on the size of the X-ray line emitter is not constrained because line flux contributions from large, parsec-scale distances could be unresolved by the HEG. We note that our results are suggestive of the fact that the location of the X-ray line-emitting region relative to the BLR may actually be different in different sources. These conclusions are subject to the caveat that derivation of the true velocity width of the Fe Kα line core requires a proper physical model, such as that of MY09, that includes a possible Compton shoulder. This will be the subject of future work. However, we note that such an analysis can only reduce the derived velocity widths of the Fe Kα lines. Finally, having isolated the narrow core of the Fe Kα line with the best available spectral resolution we confirm the anti-correlation (albeit with a large scatter) between the line EW and X-ray luminosity, Lx (the X-ray Baldwin effect), and between the line EW and Lx/LEdd.

Partial support for this work was provided by NASA through Chandra Award AR8-9012X, issued by the Chandra X-ray Observatory Center, which is operated by the Smithsonian Astrophysical Observatory for and on behalf of the NASA under contract NAS8-39073. X.W.S. and J.X.W. acknowledge support from Chinese National Science Foundation (Grant No. 10825312, 10773010), and Knowledge Innovation Program of CAS (Grant No. KJCX2-YW-T05). This research made use of the HEASARC online data archive services, supported by NASA/GSFC. This research has made use of the NASA/IPAC Extragalactic Database (NED) which is operated by the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. The authors are grateful to the Chandra instrument and operations teams for making these observations possible.

APPENDIX: NOTES ON INDIVIDUAL SOURCES

In this section we give, for each source in our sample, particular additional details of the analysis and/or results where necessary. We also summarize briefly any previously published HEG results in the Fe K band that are based on the same data. Our intention is not to review observations by other instruments.

F9. Chandra HEG results were reported in YP04 and the new analysis is consistent with the previous results. Note that the very large upper limit on the intrinsic Fe Kα line width (Table 2) is unphysical since such a broad Gaussian component is clearly modeling the underlying spectrum (see discussion in YP04). The HEG data show marginal evidence of an emission line at ∼6.9 keV.

NGC 526a. No results from either of the two observations have been previously published. The Fe Kα line is detected in only one of the observations, and the detection is marginal. Consequently, the FWHM of the line could not be constrained.

Mrk 590. Results from the Chandra HEG data have been presented by Longinotti et al. (2007), who reported the detection of a narrow Fe Kα line with E0 = 6.40+0.04−0.03 keV, σFeK = 47+58−24 eV, and EW = 160+118−78 eV. Our best-fitting Fe Kα line parameters (Table 1) are in good agreement with those measured by Longinotti et al. (2007). Figure 1 shows that the large 99% confidence region for IFeK versus E0 indicates that the fits in which the line width was free do not provide a reliable measure of the intrinsic line width.

NGC 985. Although Krongold et al. (2005) reported results from the Chandra HETGS observation, they combined HEG and MEG data and did not report results on the Fe Kα line emission.

ESO 198−G24. No results from any of the two Chandra HETGS observations have been previously reported. We obtained a significant detection of the narrow Fe Kα line from only one of the observations (Tables 1 and 2).

3C 120. Results on the Fe Kα line from the Chandra HETGS observation of this source have been reported in YP04 and the new results presented here are consistent with the previous ones. The HEG data show a marginal detection of an emission line at ∼6.9 keV (YP04).

NGC 2110. The results from the four Chandra HETGS observations were presented by Evans et al. (2007), who measured the narrow Fe Kα line parameters E0 = 6.397 ± 0.007 keV, and EW = 81+27−30 eV, consistent with our results. Note that in the second observation the line width could not be constrained so the IFeK versus E0 99% confidence contour for that observation in Figure 2 was constructed with the line width fixed at 1 eV (dot-dashed line).

PG 0844+349. No results from any of the three Chandra HETGS observations of this source have been reported previously. The detection of the Fe Kα line at ∼6.4 keV is marginal, and there is also marginal evidence of emission lines due to He-like and H-like Fe. When fitted with a single-Gaussian model, the presence of three narrow emission lines causes the Gaussian intrinsic width to become large as it tries to account for all three lines. Therefore, the most reliable values of E0 and IFeK are those obtained from fits in which the line width was fixed.

MCG−5-23-16. This source was observed by the Chandra HETGS on three occasions. Results from the first observation have been presented by Balestra et al. (2004), who found, from single-Gaussian fits to the narrow Fe Kα line, E0 = 6.38 ± 0.02 keV, EW = 70 ± 28 eV, and FWHM ⩽ 6500 km s−1 (at 99% confidence). Results from the remaining two observations were presented by Braito et al. (2007), who reported Fe Kα narrow-line parameters for the mean (time-averaged) spectrum of E0 = 6.41+0.02−0.01 keV and EW = 61+17−23 eV. These correspond to the case when the line width was fixed at a value less than the instrument resolution and Braito et al. (2007) found that if the line width was allowed to float, the constraints were sensitive to details of the continuum and relativistic disk-line model. Our results are consistent with previously published results; our simple continuum model and omission of a broad relativistic line in the fits means that our measurements of the line width should be interpreted as empirical indicators only. Note that in the second observation the 99% confidence contour of the Fe Kα line intensity versus energy was not closed when the line width was a free parameter. Thus, for this observation, we show in Figure 2 the 99% confidence contour for the line width fixed at 1 eV (thin solid line).

Mrk 705. The signal-to-noise ratio of the data in this observation was very poor. Previous results have been reported by Gallo et al. (2005) who obtained an upper limit of 149 eV on the EW of an emission line with a centroid energy fixed at 6.4 keV. This is consistent with our analysis (Table 1).

NGC 3227. Results from the Chandra HETGS observation of this source have been reported in YP04 and the new results presented here are consistent with the previous ones.

NGC 3516. There were eight Chandra HETGS observations of this source. Results from the first three observations were reported in YP04. In the present paper, we report on the analysis of five new observations that were performed in 2006 October. Results from the same data sets have also been presented by Turner et al. (2008), who reported the detection of a narrow Fe Kα emission line with E0 = 6.404 ± 0.019 keV, σFeK = 40+10−15 eV, and EW ∼ 94 eV (the statistical error was not given). In addition, redshifted emission-line features have been reported in some of the HEG data (Turner et al. 2002), as well as H-like and He-like Fe emission and absorption features (Turner et al. 2008). In the present paper we are concerned only with the Fe Kα emission line centered at ∼6.4 keV and our results are consistent with those of Turner et al. (2008). Due to the short exposure time of the last observation, the Fe Kα line was detected at less than 99% confidence (for two free Gaussian parameters). Thus, we do not show the contour of the line intensity versus energy in Figure 2 for this observation.

NGC 3783. Detailed results from the six Chandra HETGS observations of this source have been presented by Yaqoob et al. (2005) and Kaspi et al. (2001, 2002), and our re-analysis is consistent with the previous results.

NGC 4051. Results from the Chandra HETGS observation of this source have been reported by Collinge et al. (2001), who obtained E0 = 6.41+0.01−0.01 keV, EW = 158+51−47 eV, and FWHM <2800 km s−1 for the core of the narrow Fe Kα line. Our analysis is consistent with the previous results, except that when the line width was free in the fits it becomes larger than the narrow core in the data (Table 2), and this is consistent with the results reported in YP04. Absorption features due to He-like and H-like Fe have also been noted in the HEG data for NGC 4051 (Collinge et al. 2001; YP04).

NGC 4151. This source was observed five times with the Chandra HETGS. Results from the first observation have been reported by Ogle et al. (2000) who obtained EW = 160 ±  20 eV, consistent with our measurement (Table 1) and an FWHM of 1800 ± 200 km s−1, also consistent with our analysis (Table 2). The line centroid energy was not measured. Results for narrow Fe Kα line parameters measured by the HEG for the remaining four observations have not been previously published.

Mrk 766. Results for the Chandra HETGS observation of this source have been reported in YP04 and our re-analysis is consistent with the previous results. The HEG data show marginal evidence of an emission line at ∼6.9 keV (YP04).

3C 273. A narrow Fe Kα line was detected in only one of the seven Chandra HETGS observations of this source. Measurements of the Fe Kα line core from Chandra HEG data have not been previously reported.

NGC 4593. Results for the Chandra HETGS observation of this source have been reported in YP04 and our re-analysis is consistent with the previous results. The HEG data show marginal evidence of an emission line at ∼6.9 keV (YP04).

MCG−6-30-15. This source was observed by the Chandra HETGS five times. Results from the first observation have been presented by Lee et al. (2002) and YP04. The results for the other four observations were presented by Young et al. (2005), who reported narrow Fe Kα emission-line parameters from the time-averaged spectrum of E0 = 6.393+0.106−0.014 keV, EW = 18+11−8 eV, and an FWHM <4700 km s−1. In the present analysis, only one out of four new observations had a significant detection of the narrow Fe Kα emission line. From our empirical analysis we obtained a larger EW and FWHM than Young et al. (2005). This could be attributed to a contribution to the Fe Kα line core from an underlying disk-line component and/or the difference could be due to a complex continuum. However, there is a large range of possible models but in our analysis the simple empirical model is appropriate because the results can be compared directly to those from the other sources in our sample. The EW and FWHM obtained from more complex models will always be less than the values obtained from the empirical modeling so the latter provide useful upper bounds. He-like and H-like Fe absorption features have been reported in the HEG data by Young et al. (2005).

IRAS 13349+2438. This source was observed twice with the Chandra HETGS but no results for the Fe Kα line have been previously published. A significant detection of the narrow Fe Kα line was obtained only from the second observation (see Table 1).

IC 4329A McKernan & Yaqoob (2004) reported the detection of complex Fe K line emission from the Chandra HETGS observation of this source. One peak is centered at ∼6.3 keV with an FWHM 20830+10110−7375 km s−1 and an EW of 110+46−40 eV. The other peak is at ∼6.9 keV with an FWHM ∼4000 km s−1 and an EW of ∼40 eV (probably due to Fe xxvi Lyα). In the present analysis we are concerned only with the low-ionization Fe Kα line. Our re-analysis with the line width free is consistent with the results of McKernan & Yaqoob (2004) but we note that our fits in which the Fe Kα line width was fixed at well below the HEG resolution yielded a line centroid energy of 6.399+0.006−0.005 keV. Therefore, the Fe Kα line parameters from the latter fit are more reliable values for the true narrow core of the Fe Kα line.

Mrk 279. Results of the new analysis for this source are consistent with those reported in YP04.

NGC 5506. Results from the Chandra HETGS observation of this source have been presented by Bianchi et al. (2003), who obtained FWHM<4000 km s−1 for the narrow Fe Kα line at ∼6.4 keV at 99% confidence. We obtained a tighter limit on the FWHM (Table 2). Bianchi et al. (2003) did not provide constraints on the line centroid energy or EW.

NGC 5548. Results for both of the Chandra HETGS observations have already been reported in Yaqoob et al. (2001) and YP04, and the new analysis is consistent with the previous results.

Mrk 290. There are four Chandra HETGS observations for this source and no results on the Fe Kα line from the HEG data have previously been published. None of the individual observations yielded a detection of the narrow Fe Kα line greater than 99% confidence (for two free parameters). However, the line was detected with >3σ confidence in the time-averaged spectra. The line intensity against centroid energy confidence contours shown in Figure 2 was obtained with the line width fixed at 1 eV since a closed 99% confidence contour could not be obtained when the line width was a free parameter.

PDS 456. Results from the Chandra HETGS observation of this source pertaining to the narrow Fe Kα line have never been previously published. The signal-to-noise ratio is poor and we could only obtain upper limits on the EW after fixing the line energy at 6.4 keV.

E1821+643. Results from the Chandra HETGS observation of this source have been presented by Fang et al. (2002) and Yaqoob & Serlemitsos (2005). The latter work reported Fe Kα line parameters E0 = 6.43+0.06−0.05 keV, EW = 144+67−57 eV, and FWHM = 10980+3300−7690 km s−1. However, as described in Yaqoob & Serlemitsos (2005), these parameters are quite model dependent because an absorption line was reported at ∼6.2 keV in the rest frame, and there may also be an underlying broad emission line. Our fits with the line width fixed at 1 eV likely give the most representative values of the centroid energy and EW of the narrow core of the Fe Kα line.

3C 382. Gliozzi et al. (2007) have presented the results from the two Chandra HETGS observations of this source. The Fe Kα line was detected with less than 90% and less than 99% confidence in first and second observations, respectively. From the second observation Gliozzi et al. (2007) obtained E0 = 6.43+0.05−0.07 keV, EW = 55+47−20 eV, and FWHM<9560 km s−1. Our results are generally consistent with those of Gliozzi et al. (2007), but we note that the latter work also reported results from the −1 and +1 orders of the HEG separately, giving a larger dispersion in the parameter ranges.

IRAS 18325 − 5926 and 4C 74.26. No results from the Chandra HETGS observations (pertaining to the Fe Kα line or otherwise) for either of these sources have been previously published. In IRAS 18325 − 5926 our analysis revealed no significant detection of the narrow Fe Kα line in either of the two observations or from the summed spectrum. The detection of the line in 4C 74.26 was marginal even for the spectrum summed over two observations. Only upper limits on the EW could be derived for IRAS 18325 − 5926 (with the Fe Kα line energy fixed at 6.4 keV).

Mrk 509. Results from the Chandra HETGS observation of this source have been reported in YP04 and the new analysis gives consistent results.

NGC 7213. Results from the two Chandra HETGS observations of this source have been reported by Bianchi et al. (2008). The narrow Fe Kα line parameters obtained were E0 = 6.397+0.006−0.011 keV, EW = 120+40−30 eV, and FWHM = 2400+1100−600 km s−1. Our results are consistent with those of Bianchi et al. (2008), who also reported the detection of Fe xxv and Fe xxvi Lyα emission lines in the HEG data.

NGC 7314. Complex Fe K line emission from multiple ionization states was observed by the Chandra HETGS, and the results of a detailed analysis were published by Yaqoob et al. (2003). The Fe Kα line at ∼6.4 keV is unresolved with FWHM <3520 km s−1 and EW = 81 ± 34 eV. The results presented in the present paper (Table 1) were obtained from fits with the line width fixed at 1 eV. Emission lines from Fe xxv and Fe xxvi Lyα have been noted and discussed in detail by Yaqoob et al. (2003).

Ark 564. Results pertaining to the narrow Fe Kα line from the Chandra HETGS observation have been presented by Matsumoto et al. (2004) and YP04. The signal-to-noise ratio of the data is poor and the EW of the line could only be measured with the line energy fixed at 6.4 keV and the line width fixed at 1 eV, and the results are consistent with those of YP04 (Table 1).

MR 2251 − 178. Gibson et al. (2005) reported results from a Chandra observation, giving EW = 25 ± 13 eV and FWHM <1530 km s−1 for an Fe Kα line with a centroid energy fixed at 6.4 keV. In our uniform analysis, we found that the line was detected at less than 99% confidence. In this case we were not able to obtain constraints on the line width. Gibson et al. (2005) also reported the detection of a resolved Fe xxvi Lyα absorption line with EW ∼ 28 eV and a velocity shift of ∼−12700 km s−1, indicating a high-velocity outflow.

NGC 7469. Results from the two Chandra HETGS observations have been reported by Scott et al. (2005). A strong Fe Kα line was detected with a centroid energy of 6.39 ± 0.01 keV, and a line width 6310 ± 1580 km s−1. No EW was given but the line flux was 3.9 ± 0.7 × 10−5 photons cm−2 s−1. Our results are consistent (within the statistical errors) with those of Scott et al. (2005).

Footnotes

Please wait… references are loading.
10.1088/0067-0049/187/2/581