Practical Application of the CO2 Laser to Long Distance Measurement by Interferometry

and

Published under licence by IOP Publishing Ltd
, , Citation R Turner and E K Pfitzer 1970 Metrologia 6 94 DOI 10.1088/0026-1394/6/3/005

0026-1394/6/3/94

Abstract

A simple passive cavity CO2 laser has been designed and shown to be ideally suited for length measurement applications, particularly for the calibration of long tapes. The laser wavelengths for three CO2 transitions [viz. P (20) and R (18) of the 00°1 - 10°0 transition and R (22) of the 00°1 - 02°0 transition] have been measured to one part in 106. The refractive index of dry air has been measured at the above three wavelengths and found to be 1.0002688 ± 0.0000003.

Export citation and abstract BibTeX RIS