A publishing partnership

Articles

MEASURING THE PULSE OF GRB 090618: A SIMULTANEOUS SPECTRAL AND TIMING ANALYSIS OF THE PROMPT EMISSION

and

Published 2011 December 29 © 2012. The American Astronomical Society. All rights reserved.
, , Citation Rupal Basak and A. R. Rao 2012 ApJ 745 76 DOI 10.1088/0004-637X/745/1/76

0004-637X/745/1/76

ABSTRACT

We develop a new method for simultaneous timing and spectral studies of gamma-ray burst (GRB) prompt emission and apply it to make a pulse-wise description of the prompt emission of GRB 090618, the brightest GRB detected in the Fermi era. We exploit the large area (and sensitivity) of Swift/Burst Alert Telescope and the wide bandwidth of Fermi/Gamma–ray Burst Monitor to derive the parameters for a complete spectral and timing description of the individual pulses of this GRB, based on the various empirical relations suggested in the literature. We demonstrate that this empirical model correctly describes the other observed properties of the burst, such as the variation of the lag with energy and the pulse width with energy. The measurements also show an indication of an increase in the pulse width as a function of energy at low energies for some of the pulses, which is naturally explained as an off-shoot of some particular combination of the model parameters. We argue that these model parameters, particularly the peak energy at the beginning of the pulse, are the natural choices to be used for correlation with luminosity. The implications of these results for the use of GRBs as standard candles are briefly described.

Export citation and abstract BibTeX RIS

1. INTRODUCTION

The phenomenon of gamma-ray burst (GRB) has raised many unresolved issues. For example, the nature of the compact object in the progenitor responsible for the jet emission is not yet understood. The widely accepted scenario for GRB emission, supported by strong observational evidence (van Paradijs et al. 2000), is that of a catastrophic energy release from a highly massive, rapidly rotating, and low-metallicity star towards the end of its life. This catastrophic process for the long GRB class (T90 ≳ 2 s, where T90 is the time taken by the burst to accumulate between 5% and 95% of its prompt emission; see Kouveliotou et al. 1993; Norris et al. 2005) is attributed to the collapsar or hypernova scenario (Woosley 1993; Paczynski 1998; Fryer et al. 1999; Mészáros 2006a, 2006b), while the short GRBs (T90 ≲ 2 s) are thought of as the outcome of merging neutron star binaries or neutron-star–black-hole binaries (Paczynski 1986; Meszaros & Rees 1992, 1997; Rosswog & Ramirez-Ruiz 2003; Rosswog et al. 2003). Though the collapsar model supports the formation of a stellar mass black hole, it is also suggested that the compact object could be a magnetar (Metzger et al. 2007; Metzger 2010).

The prompt emission of long GRBs shows a wide range of structures in their light curve, though the time-integrated energy spectra are adequately fit by a four-parameter Band model (Band et al. 1993). Attempts have been made to fit the light curve of the prompt emission with empirical models such as the Fast Rise Exponential Decay (FRED) model (Kocevski et al. 2003) and the exponential model (Norris et al. 2005). These models assume an underlying pulse structure of the prompt emission. The curve fitting shows that the pulses are nearly simultaneous in a wide range of energy bands (Norris et al. 2005) and have self-similar shapes (Nemiroff 2000). Hakkila & Preece (2011) showed that the observed properties of the short pulses of long GRBs correlate in the same way as typical pulses of short GRBs. All these properties of pulse emission indicate that despite being diverse in their many features, the prompt emission of GRB has a simple underlying mechanism of pulse emission which can be characterized by empirical models irrespective of the progenitor or the environment of its formation (Hakkila & Preece 2011).

The properties of the prompt emission of GRBs, such as Epeak (the energy at which the emission peaks; Amati et al. 2002), the lag between the light curves at two energies (Norris et al. 2000), the average variability seen during the prompt emission (Fenimore & Ramirez-Ruiz 2000), and the rise time of the pulses (Schaefer 2002), are found to be correlated to the luminosity of the bursts and hence they are used as distance indicators (Schaefer 2007; Gehrels et al. 2009). Most of these derived relations are empirical in nature and the analyses that are done to derive these parameters, however, are done separately in the time or the energy domain. For example, to derive Epeak the time-integrated spectrum is used, ignoring the time variability and the pulse characteristics. Similarly, to derive lags, the time profile is examined in a few broad energy bands. Attempts have been made to investigate the variations of these derived parameters in the other domain. For example, the variation of Epeak with time has been investigated by Kocevski & Liang (2003). A complete empirical description of GRB prompt emission which describes the time as well as energy distribution, however, is lacking. This is probably due to the method of spectral parameter determination which is forward in nature: that is one assumes a possible spectral model, convolves with the detector response, and verifies the validity of the model by comparing with the data (Arnaud 1996). Hence, it is difficult to incorporate time variability parameters in this scheme. GRBs often have overlapping pulses which further complicates the extracting of model parameters for any unified empirical description.

In this paper, we develop a technique to give a complete pulse-wise empirical description of the prompt emission of a GRB using the time-integrated spectrum and the energy-integrated light curve. We apply this method to the Fermi/Gamma–ray Burst Monitor (GBM) and the Swift/Burst Alert Telescope (BAT) data of GRB 090618, which has the highest fluence among all 438 GBM GRBs until 2010 March (Nava et al. 2011). We exploit the large area of Swift/BAT to obtain accurate light curves and the large bandwidth of Fermi/GBM to obtain accurate energy spectra. We use the Band description for the time-integrated spectral model (Band 2003) and the exponential model (Norris et al. 2005) for the energy-integrated timing description for the pulses. We use the expression for the variation of Epeak with time given by Kocevski & Liang (2003) and develop a method to derive the model parameters (see Section 4.1.2). We demonstrate that these model parameters correctly describe the variation of pulse width with energy and the variation of the lag with energy.

In Section 2 we give a brief description of GRB 090618, and in Section 3 we give the data analysis techniques including spectral analysis (Section 3.1), timing analysis (Section 3.2), and a pulse-wise joint (Swift/BAT and Fermi/GBM) spectral analysis (Section 3.3). In Section 4 we describe our method in detail, which gives a complete three-dimensional pulse-wise description of the GRB. The model-predicted timing results are compared with the observations in Section 4.2 and the implications for global correlations are touched upon in Section 4.3. The results are discussed and the major conclusions are given in the last section (Section 5).

2. GRB 090618

The brightest GRB in the Fermi era (as of 2010 March), GRB 090618, was simultaneously observed with Swift/BAT (Schady 2009; Schady et al. 2009a, 2009b), AGILE (Longo et al. 2009), Fermi/GBM (McBreen 2009), Suzaku/Wide-band All-sky Monitor (WAM) (Kono et al. 2009), Wind/Konus-Wind, Coronas-Photon/Konus-RF (Golenetskii et al. 2009), and Coronas-Photon/RT-2 (Rao et al. 2009, 2011). This is a long GRB (T90 ∼ 113 s) with a fluence of 3398.1 ± 62.0 × 10−7 erg cm−2 (integrated over ▵t = 182.27 s). The detection time reported by Swift/BAT is 2009 June 18 at 08:28:29.85 UT (Schady 2009) whereas the Fermi/GBM detection time is 08:28:26.66 UT (McBreen 2009). This burst showed structures in the light curve with four peaks along with a precursor. A significant spectral evolution was also observed in the prompt emission which lasted for about 130 s from the trigger time (for a summary see Rao et al. 2011).

The GRB afterglow was observed in the softer X-rays and optical regions. The optical afterglow was tracked by Palomar 60 inch telescope (Cenko 2009), Katzman Automatic Imaging Telescope (Perley 2009), followed by various other optical, infrared, and radio observations. Observations using the Kast spectrograph on the 3 m Shane telescope at Lick Observatory (Cenko et al. 2009) revealed a redshift of z = 0.54 (Cenko et al. 2009). The X-ray afterglow was measured by the Swift/X-Ray Telescope (Schady et al. 2009a). Initially very bright in the X-rays, the flux rapidly decayed with a slope of ∼6 before breaking after 310 s from the trigger time when the burst entered a shallower decay phase (slope 0.71 ± 0.02— Beardmore & Schady 2009).

Rao et al. (2011) analyzed the prompt emission of GRB 090618 using Coronas-Photon/RT-2 and Swift/BAT data. The light curves in various energy bands were fitted with a FRED profile to identify pulse characteristics such as width, peak position, etc. A joint RT-2 and BAT spectral analysis of individual pulses was done using the spectral model of Band. The reported time-integrated low-energy photon index (α), the high-energy photon index (β), and the peak energy (Epeak) are −1.40, −2.50, and 164 keV, respectively. Ghirlanda et al. (2010) performed a time-resolved spectral analysis of Fermi GRBs of known redshifts (GRB 090618 being one of the twelve in the list) to show that the time-resolved correlation (EtpeakLisot) within individual GRBs is consistent with time-integrated correlation (EpeakLiso), indicating that there must be a physical origin for the correlation and may not be an outcome of instrumental selection effects.

3. DATA ANALYSIS

We used Fermi/GBM and Swift/BAT data for our analysis. The GBM consists of twelve sodium iodide (NaI: nx where x runs from 0 to 11) and two bismuth germanate (BGO: by, where y runs from 0 to 1) detectors. The NaI covers the energy range ≳8 keV to ∼1 MeV while the BGO covers a wider range of ∼200 keV to ∼40 MeV. Data are saved in three types of packets (Meegan et al. 2009): (1) time tag events (TTE) in which time and energy information (in 128 energy channels) of individual photons are stored, (2) CSPEC: binned data in 1.024 s bins and 128 energy channels, and (3) CTIME: binned data in 0.064 s bins and 8 energy channels (which is not suitable for spectroscopy). The triggered detectors for the GRB 090618 were n4, n7, b0, and b1. In the following analysis we have used n4, n7, and either b0 or b1, one at a time. On the other hand, BAT has an array of CdZnTe detector modules located behind a coded aperture mask. This covers an energy range of 15–150 keV (Barthelmy et al. 2005; Gehrels et al. 2004). The large area of BAT (5200 cm2) gives very good sensitivity for timing analysis, compared to that of NaI/BGO (126 cm2) detectors of GBM.

3.1. Spectral Analysis

Ghirlanda et al. (2010) have presented the time-resolved spectral analysis results for GRB 090618 in 14 time segments. We essentially followed the same methodology, but have also used the simultaneous Swift/BAT data. GRB 090618 triggered the Swift/BAT instrument on 2009 June 18 at 08:28:29.851 or 267006514.688 MET (s). The Fermi/GBM trigger time is T0(GBM) = 2009 June 18 08:28:26.659 UT or 267006508.659 MET (s). Hence, there is a delay time in the BAT data file which must be subtracted during the joint analysis. The calculated time delay is −3.192 s and when we convert it to MET it gives 267006511.496 MET (s) for Swift/BAT. Throughout the analysis this time is subtracted from the trigger time unless specified otherwise.

For the GBM we chose the TTE files of the triggered NaI detectors, namely, n4 and n7. The BGO detector was excluded as it is not suitable for time-resolved spectroscopy owing to its lower sensitivity (Ghirlanda et al. 2010). The energy range was chosen to be ≳8 keV to ∼900 keV. We used RMFIT package provided by the User Contributions of the Fermi Science Support Center (FSSC) to select the desired time cuts and for generating the background files. The background was taken before and after the burst, avoiding burst contamination; and the exposure time for the background was optimized for different detectors. The energy channels were binned so as to get a minimum of 40 counts per channel. For the analysis of the BAT data we used standard tasks prescribed in The Swift BAT Software Guide, Version 6.3 of Heasoft 6.9, employing a time delay of −3.192 s.

These spectra were then fitted with a cutoff power law of the form F = cons × Eαexp (− E/E0), where F is the photon flux. The constant factor, cons, was kept free while fitting essentially to take care of the different systematic errors in the area calibration of the two instruments. The derived parameter values (using GBM alone) were found to be consistent with the values presented in Ghirlanda et al. (2010). Figure 1 shows the comparison results of the spectral analysis. In Figure 1 (left panel), the indices α obtained from the joint analysis are plotted against those obtained from an analysis of the GBM data for the 14 different time segments. Similar data for the parameter E0 are shown in the right panel. A deviation is noted for the parameter α in the 0–3 s region. This may be attributed to the lower count rate of BAT in the precursor region.

Figure 1.

Figure 1. Comparison of the parameters obtained from a time-resolved spectral analysis of the prompt emission of GRB 090618 using a cutoff power-law model. The left panel shows the power-law indices obtained from a joint GBM and BAT analysis plotted against those obtained from a GBM analysis. The right panel shows a similar plot for the cutoff energy E0. In both cases, the straight line has a slope 1 denoting the equality of measurements (−α is plotted for convenience).

Standard image High-resolution image

We note a systematic increment in the value of α and E0 after the inclusion of BAT data. Further, the constant factor is always lower by 10%–20% for BAT. Sakamoto et al. (2011) have made a joint spectral analysis of 14 GRBs using data from Swift/BAT, Konus/Wind and Suzaku/WAM and they have noted that for the BAT data, the constant factor is systematically lower by 10%–20%, the photon index is steeper by 0.1–0.2, and Epeak becomes higher by 10%–20%. The results presented here are in general agreement with those conclusions.

In Figure 2, we have plotted the ratio of fractional errors as a function of the measured parameters. We find that there is a marginal improvement for the parameter E0 (Figure 2, right panel). The parameter α (Figure 2, left panel), however is always measured with a greater accuracy from the joint analysis. The large effective area of BAT improves the accuracy of the spectral index, whereas its low high energy threshold (∼150 keV) has a relatively low impact on the measurement of the high energy cutoff value. The joint analysis always gives confidence in the measured parameters and ensures that the effects of instrumental artifacts are minimized. Hence we use, in the later analysis, a joint fit for measuring the global spectral parameters and use only the BAT data for a joint timing and spectral analysis.

Figure 2.

Figure 2. Ratio of fractional errors for GBM–BAT joint analysis to the GBM analysis is shown as a function of the measured values of α (left panel) and E0 (right panel) obtained from a fitting for GBM data alone. The dotted line in both cases shows the average of all errors measured. This is found to be marginally less than the line of equal error (dot dashed) for E0 and well below that line for α measurement (−α is plotted for convenience).

Standard image High-resolution image

3.2. Timing Analysis

We identified four pulses (other than the precursor) in the ∼60 s to ∼130 s period after the trigger. Both Swift/BAT and Fermi/GBM (n4) were used for the timing analysis. We subtracted the background and shifted the time origin to the trigger time (TRIGTIME is the keyword in the header) of the respective satellite. As we noted previously, there is a time lag of −3.192 s for the BAT trigger. Light curves were extracted for different energy bands for both data sets. The energy bands for Swift/BAT were 15–25 keV, 25–50 keV, 50–100 keV, and 100–200 keV. For Fermi/GBM (n4), we chose 8–15 keV, 15–25 keV, 25–50 keV, 50–100 keV, 100–200 keV, and 200–500 keV. Greater than 500 keV region of NaI and the BGO detector of GBM were excluded because the third and the fourth pulses were not detected in these bands.

All light curves were fitted with the four-parameter model of Norris et al. (2005):

Equation (1)

for t > ts, where $\mu =\left(\tau _{1}/\tau _{2}\right)^{\frac{1}{2}}$ and λ = exp (2μ). An is the pulse amplitude, ts is the pulse start time, and τ1, τ2 are time constants characterizing the rise and decay part of the pulse. From these parameters, various derived quantities like the peak position, pulse width (measured as the separation between the two 1/e intensity points), and pulse asymmetry can be calculated (see Norris et al. 2005 for details). Errors are calculated for the parameters as nominal 90% confidence level errors (▵χ2 = 2.7) and these errors are propagated for the derived quantities, as described in Norris et al. (2005).

Figure 3 shows the pulse width (w) as a function of energy (E) for all the pulses. Apart from the fact that the width broadens in the lower energy bands, we note a tentative evidence for a decrement (or constancy within error bar) of the width from 50–100 keV through 8–15 keV energy bands for the third and the fourth pulses (lower panels of Figure 3). We fitted these data for the individual pulses with (1) constant (w = c) and (2) linear (w = mE + c) models. For the first two pulses, there was a significant improvement in the χ2 for a linear fit (the χ2 varied from 16.2(9) to 5.1(8) and 140.9(9) to 7.9(8), respectively for the two pulses; the numbers in the parentheses are the degrees of freedom). The derived slopes are (− 7.4 ± 2.6) × 10−3 s keV−1 and (− 5.5 ± 0.4) × 10−3 s keV−1, respectively, for the two pulses. The third and the fourth pulses, however, showed negligible improvement in χ2 (from 8.7(9) to 6.0(8) and 2.1(8) to 2.1(7), respectively, for the two pulses) for the linear fit. For these two pulses, when the data below 70 keV is considered, there is a marginal improvement in the χ2 for a linear fit with a positive slope (from 8.7(9) to 3.8(5) and 2.1(8) to 1.5(5), respectively, for the two pulses). The derived slopes are (15 ± 14) × 10−3 s keV−1 and (10 ± 21) × 10−3 s keV−1, respectively. Though the slopes for these two pulses are positive, the error bars are quite large and hence the evidence of this reverse variation is tentative. In Figure 3 (lower two panels), the linear fits for pulses 3 and 4 are shown by solid lines (in the low energy) and dot-dashed lines (in full energy band). We have ignored the fourth pulse in the 200–500 keV band of Fermi for the fitting as it was not prominent in this energy band.

Figure 3.

Figure 3. Pulse width (w) is plotted against energy (E), for pulses 1–4, respectively, in the top to bottom panels. The fourth pulse is insignificant in the 200–500 keV energy range. Hence, the fourth panel has a different scale on the x-axis. Values derived from the Swift/BAT and the Fermi/GBM data are shown by circles and filled circles, respectively. While the width decreases with increasing energy for the first two pulses (top two panels), there is a tentative evidence of the reverse effect in the lower energy (∼10–70 keV band) for the other two pulses (see Section 3.2).

Standard image High-resolution image

3.3. Pulse-wise Joint Spectral Analysis

The peak position and the width gave a clue for the time cut for each pulse and facilitated the selection of integration time for pulse spectral analysis of the individual pulses. The pulse spectral analysis was done with a Band function fit and including the BGO detector of GBM. We included the precursor pulse in this analysis. We divided the GRB event into four time segments, namely, Part 1 (T0 to T0 + 50), Part 2 (T0 + 50 to T0 + 77), Part 3 (T0 + 77 to T0 + 100), and Part 4 (T0 + 100 to T0 + 180). The first and second pulses are considered together as there is too much overlap between them.

All spectra were fitted in the energy range ∼8 keV to ∼1 MeV with the four-parameter model of Band (Band et al. 1993):

Equation (2)

The lower and higher energy parts are characterized by the parameters α and β, respectively, and they meet smoothly at the spectral break energy [(α − β)/(2 + α)]Epeak. The peak energy, Epeak or equivalently the characteristic energy, defined as E0 = Epeak/(2 + α), may be considered as the third parameter of the model. The best-fit model parameters along with the nominal 90% confidence level error (▵χ2 = 2.7) for the joint fit of Fermi/GBM (n4, n7, b1) and Swift/BAT are reported in Table 1 (b0 in place of b1 gives similar results). The high-energy photon index β is constrained primarily by the GBM data and hence we have kept its value fixed at −2.5 to determine precise values of Epeak and α. Only in one case, namely, for the full range (T0 to T0 + 180 s) of the GRB, β was made to vary and a value of −2.96 was obtained. Figure 4 shows the joint Band spectral fitting of this range along with the χ2 deviation of the data.

Figure 4.

Figure 4. Fitting of the Band function to the full range (0–180 s) of GRB 090618 for the energy range ∼8 keV to ∼1 MeV. The range of the BGO detector starts above 200 keV, while BAT covers up to ∼150 keV. The other two detectors namely n4 and n7 have the spectrum above 8–800 keV. The extreme channels and specifically the 25th channel of n4 are ignored due to high background rates. The unfolded spectrum of BAT shows a lower normalization (see the text).

Standard image High-resolution image

Table 1. Spectral Parameters of GRB 090618 for the Band Model, from a Joint Analysis of Fermi/GBM (n4, n7, b1) and Swift/BAT Data

Part α β Epeak χ2 E0
      (keV) (dof) (keV)
Full −1.35 ± 0.02 −2.5 (fixed) 154 ± 7 428(299) 236 ± 18
Part 1 (precursor) −1.25 ± 0.05 −2.5 (fixed) 166+18− 14 369(299) 221+39− 33
Part 2 (pulses 1 and 2) −1.11 ± 0.02 −2.5 (fixed) 212 ± 9 460(299) 238 ± 15
Part 3 (pulse 3) −1.15 ± 0.03 −2.5 (fixed) 114 ± 4 334(259) 134 ± 9
Part 4 (pulse 4) −1.65+0.11− 0.08 −2.5 (fixed) 33 ± 3 431(299) 94+38− 30
Full (free β) −1.36 ± 0.02 −2.96 ± 0.48 160+9− 8 418(288) 250+22− 20

Download table as:  ASCIITypeset image

An examination of the residuals in Figure 4 reveals that there are some systematic differences in the response in the 20–40 keV region between BAT and GBM data and the resultant χ2 values generally are quite high. The resultant spectral parameters, however, agree with the results reported for this GRB (Ghirlanda et al. 2010; Nava et al. 2011; Rao et al. 2011). The errors are significantly better compared to the joint BAT and RT-2 analysis (Rao et al. 2011), but comparable to that obtained from a GBM analysis alone (Nava et al. 2011). Since a joint analysis using data from different satellites pins down the systematic errors in each instrument, we believe that the joint analysis results reported here are devoid of instrumental artifacts, particularly for the parameters α and Epeak.

4. JOINT SPECTRAL AND TIMING STUDY: AN ALTERNATIVE APPROACH

4.1. Two-parameter XSPEC Table Model

4.1.1. The Time Evolution of Epeak

The light curve of each pulse of a GRB can be described in terms of the four-parameter model of Norris (Equation (1)) and the spectrum for each pulse can be fitted with the Band model (Equation (2)). Liang & Kargatis (1996) showed for clean, separable pulses that the peak energy of the νFν spectrum, Epeak, decays with the photon fluence as

Equation (3)

where Epeak, 0 is the peak energy at zero fluence, ϕ0 is the decay constant, and t' = tts. The quantity ϕ(t') is the fluence up to time t from the start of the pulse (ts). For convenience of description we shift our origin to ts and hence t' = t for each pulse analysis. Equation (3) quantifies the overall softening of the burst with time.

Kocevski & Liang (2003) have integrated the light curves of a sample of GRBs up to various times t and found the fluence, ϕ(t), at those times. The peak energy at the same times, Epeak(t), was found by fitting the spectra with a Band model. They determined Epeak, 0 and ϕ0 from a semi-log plot of Epeak(t) versus ϕ(t) and fitting a straight line. This procedure was adopted for clean, bright, and separable FRED pulses.

Here we explore a method to determine the timing and spectral parameters by assuming that Epeak(t) and ϕ(t) are related according to Equation (3) in each pulse. Essentially we assume that for each pulse, the variation of flux with time is given by the exponential model (Equation (1)), and at each time the spectra are described by a Band function (Equation (2)), and, for a given pulse, only the peak energy varies with time governed by Equation (3). We develop a method to derive the model parameters from a time-integrated spectrum and energy-integrated light curve.

4.1.2. Description of the Method

The flux of a GRB pulse is a function of time and energy. If there exist empirical formulae for the temporal and spectral behavior then the flux can be described in terms of all the model parameters. For example, the variation of flux with time is given by Norris' exponential model, with four parameters (An, the normalization, ts, τ1, and τ2). The spectral behavior is parameterized by a Band function, with four parameters (Ab, the normalization, α, β, and Epeak). For any timing model, the time parameters change with energy, e.g., the derived parameter, width, changes in various energy bands (see Section 3.2). Similarly, the spectral parameters of any spectral model change with time, e.g., α and E0 of cutoff power law change with time in the same pulse (see Section 3.1).

The Norris exponential model (Equation (1)) describes the evolution of a pulse with time. This description can be used for counts in any energy band and the variation of the model parameters with energy can be studied. Instead, we assume that the model parameters τ1 and τ2 derived for a pulse integrated over all energy bands are global parameters describing the evolution of total flux with time. Since the variation of spectrum is best described by the peak energy evolution with fluence (Equation (3)), we further assume that α and β do not change with time. The normalization factors (An and Ab) are related by the fact that the fluence calculated either by time integration of the pulse light curve or by the integration over the total energy should be the same. With these assumptions, the parameters for a given pulse are determined as follows.

For a given pulse, we use the energy-integrated light curve from BAT and use Equation (1) for the fitting. This best-fit light curve is used to determine the global parameters, namely, An, τ1, and τ2. Since we can arbitrarily choose the pulse starting time by shifting the time origin, the parameter ts is not very relevant (also see Section 4.1.1). This function is then integrated up to a time t to determine ϕ(t). From the individual spectral fitting for each pulse using the Band model, α and β are determined (see Section 3.3). Now, if the constant parameters, namely, Epeak, 0 and ϕ0 are determined, we have a complete spectral and timing description of a GRB pulse. For this purpose, we use a two-dimensional grid of guess values for these two parameters and then determine the best-fit values by a spectral fitting method.

For a particular combination of Epeak, 0 and ϕ0 values, Epeak(t) at any time t can be determined from Equation (3). On the other hand, Equation (2) can be rewritten as I(E) = Abf(E), where Ab is the normalization and f(E) is the rest of the functional form valid in the two energy bands. Given the global parameters (α and β) and the time-dependent parameter (Epeak(t)), f(E) can be determined. The normalization Ab(t) can be found by dividing the fluence (ϕ(t)) of the light curve by f(E) integrated over the whole energy range. Hence photon spectrum is generated for the time instance t. Choosing a time and energy grid, counts can be plotted as a function of time and energy for a particular combination of Epeak, 0 and ϕ0 values, and the resulting surface can be referred to as a three-dimensional pulse model. Hence, for a two-dimensional grid of guess values of Epeak, 0 and ϕ0 we can generate three-dimensional pulse models for each of the grid points. These model pulses can be used in two ways: (1) integration over time gives the model spectrum of that pulse and (2) integration over various energy bands gives model light curves of that pulse in those energy bands.

In our analysis, we first generate a two-parameter XSPEC table model using the guess values of Epeak, 0 and ϕ0 and then use this table model to determine the best-fit values of these two parameters by fitting the time-integrated spectrum (see Section 4.1.3). With this method, we get a complete description of the pulse with model parameters determined from the data. Using this model we can reconstruct the three-dimensional pulse profiles and can generate light curves in any energy band. Various timing parameters (width and lag) are derived in these energy bands (see Section 4.2) and these model-predicted values can be compared with the observed values to get a validation of the whole procedure.

4.1.3. Specification of the Table Model and the Best-fit Values

For all the pulses, we use a time-grid resolution of 0.5 s and energy-grid resolution of 2.0 keV. Each pulse has a separate XSPEC table model, though the first and second pulses are combined together as the data overlap. A typical table model contains a spectrum in the 2–200 keV energy range for 200 values of Epeak, 0 from 100.0 keV to 1100.0 keV and 50 values of ϕ0 from 2.0 photon cm−2 to 77.0 photon cm−2, energy binning information, parameter values, and the required header keywords standardized as per the requirement by XSPEC described in OGIP Memo OGIP/92-009.

The additive table model is used to determine the best-fit values of Epeak, 0 and ϕ0 by the standard χ2 minimization procedure. The best-fit values with nominal 90% confidence errors are reported in Table 2. The parameters, Epeak, 0 and ϕ0 of the first two pulses are assumed to be the same. It should be noted here that we have used the normalization An as a global parameter to calculate ϕ(t). The normalization of the subsequent pulse profile is derived from the integration of f(E) over the total energy band (see Section 4.1.2). Effectively this leads to a spectrum with normalization as a free parameter. This normalization is determined during the spectral fitting using XSPEC, and is also reported in Table 2.

Table 2. Best-fit Values of Epeak, 0 and ϕ0 for the Pulses as Determined by the χ2 Minimization of the Spectral Data with the Additive Table Model

Pulse Epeak, 0 ϕ0 Norm χ2 τ1 τ2 ts
        (dof) (s) (s) (s)
1 359+65− 92 12.2+2.5− 1.3 0.74 ± 0.06 40.12 (75) 795.4+7.2− 7.1 0.54+0.005− 0.005 40.1+0.2− 0.2
2         858.2+6.4− 7.7 0.58+0.004− 0.005 44.2+0.2− 0.2
3 324+82− 83 18.8+9.6− 6.2 0.54 ± 0.04 31.41 (75) 353.4+43− 50 2.47+0.12− 0.09 50.3+1.5− 1.2
4 307+41− 99 12.0+2.0− 2.1 0.19 ± 0.04 56.42 (75) 532.0+209− 132 1.58+0.15− 0.16 81.0+2.6− 3.4

Notes. The first two pulses are combined together. The other pulse characteristics (τ1, τ2, and ts) are also reported.

Download table as:  ASCIITypeset image

4.1.4. Three-dimensional Pulse Model for the Best-fit Values

The three-dimensional model of each pulse is generated for the best-fit parameter values (as described in Sections 4.1.2 and 4.1.3). The three-dimensional model of the whole GRB obtained from the sum of these models of the pulses with each pulse shifted to its proper starting time is shown in Figure 5. This figure is used only for display purposes. In the actual analysis, each pulse is normalized properly before calculating various parameters as the overall normalization may vary for each pulse. This normalization is achieved for the spectrum and light curve separately.

Figure 5.

Figure 5. Three-dimensional model of the whole GRB using a model with the best-fit values of Epeak, 0 and ϕ0 for each pulse. Counts in arbitrary unit are plotted in the vertical axis against time and energy. The pulses are shifted to original pulse start time (see Table 2).

Standard image High-resolution image

4.2. Timing Analysis Using the Model

4.2.1. Reproducing the Light Curves

Once we get the best-fit values of Epeak, 0 and ϕ0 for each pulse, we can generate the best-fit model light curve by integrating the three-dimensional pulse model for the best-fit value over the desired energy range. We generate three-dimensional pulse models, shift them over appropriate starting time, co-add them with proper normalization factors, and integrate over energy ranges to generate the combined light curves in the energy bands 15–25 keV, 25–50 keV, 50–100 keV, and 100–200 keV of BAT. In Figure 6 (right panel), we show the observed light curve along with the model-predicted light curve for the 25–50 keV energy band. In the left panel, Norris' exponential model fit for the total energy range is shown. Parameters from this fit (Figure 6, left panel) were used for characterizing the timing parameters in our model.

Figure 6.

Figure 6. Observed light curve in the full energy range 15–200 keV fitted with Norris' exponential model is shown in the left panel. The timing parameters are determined and used in the pulse generation to predict light curves in all energy bands. One such predicted light curve in the 25–50 keV region is shown along with the observed light curve in the right panel. The count s−1 in the y-axis is BAT mask weighted count s−1.

Standard image High-resolution image

The GRB light curve shows rapid time variable components over and above the smooth pulse structure. In the pulse description we consider only this smooth variation. Any small rapid time variability in the data gives large value of χ2 when we use the smooth pulse model for fitting. Hence, the normalization factor could not be determined by χ2 minimization. Instead, we physically examined the heights and determined the normalization. The co-added pulses reproduce the light curve quite well. Hence, we can conclude that the total light curve and the integrated spectrum, with the assumption of Epeak(t) varying with ϕ(t) in a predetermined way (Equation (3)), correctly reproduces the energy-resolved light curves. This can be taken as a confirmation of the assumption of the Epeak variation. It should, however, be noted that a single joint spectral fit is done for pulses 1 and 2 and hence the derived values of Epeak, 0 and ϕ0 for the first two pulses are only the average values.

4.2.2. Derived Timing Parameters

The pulse width of individual pulses in the various energy bands can be derived by fitting the light curve using Equation (1) and using the best-fit values of τ1 and τ2 (see Section 3.2). For overlapping pulses this method is erroneous, e.g., the rising part of one pulse can fall on top of the falling part of the previous pulse thus affecting the width. Also, pulse delay characteristics are affected by these overlaps. In such cases the method described here is very useful. It takes as an input some global parameters (An, τ1, τ2, α, and β) which are average quantities characterizing the pulse and some constant parameters (Epeak, 0, ϕ0), determines the variable parameter (Epeak(t)) over the time grids, and generates the three-dimensional model of the pulse. Note that the timing parameters τ1 and τ2 are determined from the energy integrated light curve and are fixed in our model. The timing properties of the pulse (e.g., width in various energy bands, spectral delay) are now determined crucially by the evolution of the peak energy. Integration of the three-dimensional model in various energy bands generates the light curves in those energy bands. Hence, physically we can determine the full width at the 1/e intensity and the peak positions. We define the spectral delay as the shift in the peak position at each energy band compared to the lowest energy band (15–25 keV).

The derived pulse width and delay are reported in Tables 3 and 4, respectively. In Table 3, the numbers in parentheses are the width determined from Norris' exponential fitting for individual light curves. Figure 7 shows a comparison between the measured width following the new method with that determined by fitting the light curve. We note a systematic decrement of the width measurement by our method for the first two pulses. This is simply due to the fact that individual pulses rather than co-added pulses are taken into consideration. Hence, measured widths are more accurate and devoid of contamination effects from other pulses.

Figure 7.

Figure 7. Comparison of the width of individual pulses in various energy bands determined by directly fitting the light curves (Norris model fit) and the three-dimensional model prediction (new method).

Standard image High-resolution image

Table 3. Variation of the Model-predicted Width of Each Pulse with Energy

Pulse 15–25 25–50 50–100 100–200
  keV keV keV keV
1 6.05+0.12− 0.12 (6.74+0.13− 0.13) 5.88+0.16− 0.16 (6.67+0.39− 0.39) 5.54+0.16− 0.17 (6.18+1.62− 1.62) 5.08+0.15− 0.18 (5.79+0.30− 0.30)
2 6.56+0.22− 0.19 (7.52+0.13− 0.13) 6.35+0.22− 0.19 (7.40+0.04− 0.04) 5.89+0.27− 0.34 (7.23+0.11− 0.11) 5.33+0.20− 0.34 (6.82+0.04− 0.04)
3 17.84+0.47− 0.70 (18.01+3.91− 3.91) 18.10+0.53− 0.89 (18.09+0.40− 0.40) 18.68+0.74− 0.96 (17.22+1.43− 1.43) 19.82+0.49− 0.64 (15.87+1.63− 1.63)
4 14.45+0.99− 0.92 (13.32+0.51− 0.51) 14.66+0.98− 0.96 (13.76+1.60− 1.60) 15.18+0.62− 0.88 (14.00+1.23− 1.23) 15.93+1.16− 1.27 (13.03+1.84− 1.84)

Note. Numbers within parentheses are the measured pulse widths.

Download table as:  ASCIITypeset image

Table 4. Variation of the Model-predicted Delay with Energy for Each Pulse

Pulse Energy Channel Mean Energy Delay
    (keV) (s)
1 15–25 vs. 25–50 keV 35.45 −0.135+0.011− 0.022
  15–25 vs. 50–100 keV 68.07 −0.375+0.023− 0.039
  15–25 vs. 100–200 keV 123.73 −0.730+0.043− 0.045
2 15–25 vs. 25–50 keV 35.45 −0.195+0.005− 0.005
  15–25 vs. 50–100 keV 68.07 −0.555+0.033− 0.033
  15–25 vs. 100–200 keV 123.73 −1.070+0.023− 0.037
3 15–25 vs. 25–50 keV 35.45 −0.015+0.0410.040
  15–25 vs. 50–100 keV 68.07 −0.040+0.012− 0.030
  15–25 vs. 100–200 keV 123.73 −0.085+0.005− 0.005
4 15–25 vs. 25–50 keV 35.45 −0.020+0.010− 0.010
  15–25 vs. 50–100 keV 68.07 −0.065+0.035− 0.040
  15–25 vs. 100–200 keV 123.73 −0.095+0.005− 0.005

Note. Delay is calculated with respect to the 15–25 keV band (mean energy: 20.82 keV).

Download table as:  ASCIITypeset image

One of the pulse properties of GRB is broadening at lower energies (Norris et al. 1996; Hakkila & Preece 2011). Figure 8 (left panel) shows the pulse width variation with energy. While the first two pulses follow the normal trend, we note that the width for the third and fourth pulses broadens with higher energy. This cannot arise from the contamination of the previous pulse as could have been the argument for fitting the entire light curve. In our case, each pulse is generated and analyzed separately for the width determination. The energy–width plot of individual pulses is fitted with a linear model. The slopes are negative for the first two pulses ((− 9.4 ± 1.7) × 10−3 s keV−1 and (− 11.8 ± 2.4) × 10−3 s keV−1, respectively; χ2 = 0.13 (2) and 0.11 (2), respectively) and positive for the other two ((18.8 ± 11.1) × 10−3 s keV−1 and (14.2 ± 10.6) × 10−3 s keV−1, respectively; χ2 = 0.0046 (2) and 0.0021 (2), respectively). Figure 8 (right panel) shows a comparison of the slopes measured by the linear fit of data determined by the two methods (compare slopes determined in Section 3.2). We note again that the slopes of the first two pulses are convincingly negative (low error bar), but slope of the other two pulses has large error bars. Hence, the evidence of reverse pulse broadening is tentative, though individual pulse analysis in the new method shows a better evidence for the reverse pulse broadening effect (see Figure 8, left panel).

Figure 8.

Figure 8. Left panel: pulse width (w) variation with energy (E) as predicted by our model. Pulses 1–4 are shown from the top to bottom panels. Width broadens with lower energy for the first two pulses (normal width broadening) while the reverse effect is apparent for the third and the fourth pulses (anomalous width broadening). Right panel: comparison of slopes of E–w curves determined by Norris, model and the new method.

Standard image High-resolution image

This deviation from the canonical pulse width broadening with energy decrement may have a physical significance. In our analysis, the physical process of pulse emission is not considered. But phenomenologically, this occurs depending on the values of τ1 and τ2. A detailed comparison between the first pulse and the third pulse reveals the fact that they have different pulse width variation albeit having nearly similar parameters except for τ1 and τ2. These values are as follows (the numbers within parentheses are those of the third pulse): α = −1.11 (−1.15), β = −2.5 (−2.5), Epeak, 0 = 359 (324), ϕ0 = 12.2 (18.8), τ1 = 795.4 (353.4), and τ2 = 0.54 (2.47). It is apparent that the main contributing factors for the different width–energy relation are the global values of τ1 and τ2. Hence, we examined for a generic pulse keeping all other parameters fixed at the values of the first pulse and varying τ1 for different values of τ2.

Figure 9 shows the regions in which pulse broadening or its reverse phenomenon can occur. This figure is generated by fixing all the parameters other than τ1 and τ2 to those for the first pulse. For four values of τ2 we vary τ1 and note the ratio of the width in 100–200 keV region (w4) to that in the 15–25 keV (w1) region. The solid line parallel to τ1 with w4/w1 = 1 divides the plot into two regions: (1) normal width broadening region for which w4 < w1 and (2) anomalous width broadening region for which w4 > w1. Global values of τ1 and τ2 falling in the w4 < w1 region will lead to normal pulse broadening (i.e., pulse broadens with lower energy) and vice versa. We identify from the figure that the τ1 and τ2 values (795.4 and 0.54, respectively) of the first pulse lie well within the region of normal width broadening. We also note that the values of τ1 and τ2 for the third pulse (353.4 and 2.47, respectively) lie within the region of anomalous width broadening despite the fact that the parameter values used, other than τ1 and τ2, are those of the first pulse. This shows how insensitive the pulse broadening effect is with all other parameters and crucially determined by the global values of τ1 and τ2.

Figure 9.

Figure 9. Ratio of the width in 100–200 keV (w4) to the width in 15–25 keV (w1), as predicted by the pulse model, is plotted against τ1 for different values of τ2. In the figure, maximum as well as the minimum of the curves move to lower τ1 values for higher τ2. The values of τ2 are 0.54, 1.20, 1.90, and 2.47, respectively from left to right. The τ1 values determined for the second and the third pulses of the GRB (795.4 s and 353.4 s, respectively) are shown by dash-dotted lines. The solid line divides the region into two parts: the normal width broadening region and the anomalous width broadening region (see Section 4.2.2).

Standard image High-resolution image

Another pulse property is the hard-to-soft spectral evolution. In Figure 10, we have plotted the model-predicted delay as a function of energy (left panel). It can be seen that the spectral time delay always shows a decrement with energy. The hard X-ray always precedes the softer one. The values for the first three peaks can be compared with the observed delay given in Rao et al. (2011) and this is shown in the right panel of Figure 10. The time intervals taken by Rao et al. (2011) are T0 to T0 + 50 s, T0 + 50 s to T0 + 77 s, T0 + 77 s to T0 + 100 s, and T0 + 100 s to T0 + 180 s. Among these the first time bin contains the precursor burst which is not taken in our calculation. The first and second pulses are combined in the second time bin. The third pulse is covered in the third time bin. Data of the fourth pulse cannot be compared with the time bin as they differ by ∼55 s (80 s in time bin as compared to ∼25 s in pulse analysis). The deviation of the model-predicted delay from the observed delay can be explained by the fact that the delay in the second time bin (T0 + 50 to T0 + 77) is the combined effect of the first two pulses. The data for the third time bin agrees within error with the model-predicted delay. Also, the observed delays are calculated using the peak position measurement and cross correlation of the pulses, whereas model-predicted delays are calculated from the peak position measurement alone.

Figure 10.

Figure 10. Model-predicted delay of light curve with mean energy E, with respect to the 15–25 keV light curve (left panel). For the four pulses the data are shown as squares, circles, triangles, and stars respectively. The right panel shows the comparison of the measured delay (Rao et al. 2011) with the model-predicted delay. The lower six points are the model prediction for first and second pulses compared with the 50–77 s interval (see the text). The end points along the x-axis for this data group are the model-predicted delays with the left one for the second pulse. The measured delay along with the error is shown in the y-axis. The straight line is the line of equality.

Standard image High-resolution image

4.3. Correlations and the Bigger Picture

One of the important properties of the prompt emission is that the various measured quantities correlate with luminosity. Particularly, the peak energy of the νFν spectrum, Epeak, correlates with isotropic energy Eiso (Amati et al. 2002) and also with the peak isotropic luminosity Liso (Yonetoku et al. 2004). Ghirlanda et al. (2004) showed that the correlation is tighter with collimation-corrected energy, Eγ. Schaefer (2007) used a set of 69 GRB samples (up till 2006 June 7) with measured redshift to calculate various correlations, viz., lag–luminosity (τlagL), variability–luminosity (VL), EpeakL, EpeakEγ, minimum-rise-time–luminosity (τRTL), number-of-peaks-luminosity (NpeakL) to get distance moduli for each. Weighted average of them gave the distance modulus (μ) which is plotted against the measured redshift (z) extending the Hubble Diagram (HD) to z > 6. Therefore, these correlations can be used to standardize the GRB energy budget making GRBs a class of cosmic distance indicators. Also, these correlations might point to an underlying fundamental physical process (Yamazaki et al. 2004; Rees & Mészáros 2005; Xu et al. 2005; Firmani et al. 2005, 2006, 2007; Ghirlanda et al. 2006a, 2006b; Wang & Dai 2006; Thompson 2006; Thompson et al. 2007; Liang & Zhang 2005; Liang et al. 2008, and references therein; Li et al. 2008; Qi et al. 2008).

In order to establish the reality of these correlations one must show that all of these correlations hold just as the same way within a single GRB as for a sample of many GRBs. Ghirlanda et al. (2010) showed for a set of GRBs that the time-resolved correlations of a single GRB are similar to the time-integrated correlations among different GRBs. In the present work, we have used the underlying pulse structure to investigate the correlations: Epeak, 0Liso, Epeak, 0Eγ, iso, ϕ0Liso, and ϕ0Eγ, iso within the pulses of a single GRB.

The correlations are shown in Figure 11. The mean and 3σ scatter of EpeakLiso (top left panel) and EpeakEγ, iso (top right panel; Ghirlanda et al. 2010) are shown for reference. As expected, the Epeak, 0 values always lie above the mean of the Epeak values. It seems that the correlations of Epeak, 0 with Liso and Eγ, iso are rather tighter in our case, though with only three points we cannot draw any definite conclusions. While the parameter Epeak, 0 is a constant, Epeak is an average quantity. Hence, we expect that Epeak, 0 provides a better pulse description than Epeak. This can be tested in future for correlations of Epeak, 0 rather than Epeak with other quantities in different GRBs. But if the same correlations hold for different GRBs then we might conclude (1) the correlations are rather physical and not an outcome of the bias in sample selection and (2) in a single multi-peaked GRB each pulse is generated independently. We also note that the calculated Liso and Eγ, iso are somewhat lower than those calculated by Ghirlanda et al. (2010). This must have come from the instrumental effect as noticed earlier. The normalization of BAT is always less than that of Fermi. This leads to a lower flux calculated from the BAT spectrum.

Figure 11.

Figure 11. Correlations between (a)Epeak, 0Liso (left panel, top); the dot-dashed line is the mean EpeakLiso curve while the dashed lines represent 3σ scatter (from Ghirlanda et al. 2010), ϕ0Liso (bottom); the dot-dashed line is the mean ϕ0Liso line (from Kocevski et al. 2003) and (b) Epeak, 0Eγ, iso (right panel, top); the dot-dashed line is the mean EpeakEγ, iso curve while the dashed lines represent 3σ scatter (from Ghirlanda et al. 2010), ϕ0Eγ, iso (bottom).

Standard image High-resolution image

5. DISCUSSION AND CONCLUSIONS

We have attempted to explain the timing and spectral variations within a pulse of GRB by a simple empirical model and have given a prescription to measure the parameters of this model. We use simultaneous data from Swift/BAT and Fermi/GBM to determine the average pulse spectral characteristics using the Band model. Then we use the integrated light curve from Swift/BAT to get a simple description of the time evolution using Norris' exponential model. Using these parameters, we develop a method to fit the spectrum using XSPEC table model by assuming that Epeak(t) decreases exponentially with fluence in the pulse. We determine the parameters of the model and then find that these parameters can correctly describe the energy dependence of the pulse characteristics such as width and spectral lags. We also find, in the data, a tentative evidence of anomalous width broadening with energy for some pulses. The joint spectral and timing analysis developed here confirms this phenomena for the same pulses at least in the lower energy bands.

The method developed here is applicable for both single pulse and structured GRBs. Most of the long GRBs are structured which makes them difficult for pulse analysis. As far as the correlations are concerned, pulse analysis is more indicative than intensity-guided time-resolved spectroscopy. Hence to draw a conclusion regarding these correlations within a sample of GRBs and within the pulses of a single GRB, we must include these structured GRBs with multiple pulses. Kocevski et al. (2003) have prescribed a method for short, clean pulses. Our method extends the domain to all kinds of GRBs. Also the present method is much more physical than the time-resolved one in the sense that the individual pulses are treated separately. Hence, there will not be contamination effects. The LisoEpeak, 0 looks tighter because correlations within pulses may be more physical than the time-resolved correlation or the time-integrated correlations. In future, the method developed here can be used for a large set of GRBs (onto their individual pulses) to investigate the improvement in the correlations.

It is very interesting to note that the two distinct pulses (pulse 3 and pulse 4) in GRB 090618 have Eiso values within a factor of two, but widely different Epeak values (114 keV and 33 keV, respectively). They will show a huge scatter if used individually for a global correlation. The Epeak, 0 values, on the other hand, are closer to each other and lead to a lower scatter in the correlation (see Figure 11, top right panel). Hence, we suggest that the empirical relations are intrinsic to the emission mechanism of GRBs and Epeak, 0 values, instead of Epeak, should be the correct parameter to be used for correlation studies.

The method described in this paper is quite generic in the sense that any empirical description of the spectrum and its evolution with time can be tested against the data and the derived parameters can be used for global correlation studies. For example, the Band spectrum is derived from an extensive study of data from Compton Gamma Ray Observatory/BATSE, which is primarily sensitive above 50 keV (Band et al. 1993). Extension of the data to lower energies in fact requires additional features. For example, a time-resolved spectral study of GRB 041006 using HETE-2 data covering the energy range of 2–400 keV, indicated the presence of soft components, each of them having distinctive time evolution (Shirasaki et al. 2008). We emphasize again here that the use of different instruments can help in pinning down the systematics, identifying additional spectral components, and developing an empirical spectral formalism. The simultaneous data from Swift/BAT and Fermi/GBM have the potential to explore the existence of additional components because the highly sensitive BAT has an energy range (∼15 keV–200 keV) which is a subset of the GBM energy range. Our joint analysis of BAT and GBM data has shown that in the 20–40 keV region there is a distinct discrepancy. This could be due to (1) systematic errors in each of the detectors, (2) presence of additional components, or (3) an interplay of both of these. Since the spectral fitting method used in XSPEC is forward in nature (that is fold the assumed spectrum and compare with the data; see Arnaud 1996), the derived spectral parameters will have strong a bias of the bandwidth of the detectors, particularly for such low-resolution spectral data. Hence, a joint fitting of data with good overlap will result in a better estimate of the parameters.

In conclusion, we have developed a method to test empirical descriptions of the energy spectra and their evolution with time in GRBs and to derive the underlying physical parameters. This is the first attempt in this different approach to study various parameters and predict quantities like spectral delay and pulse width of individual pulses in a GRB.

This research has made use of data obtained through the HEASARC Online Service, provided by the NASA/GSFC, in support of NASA High Energy Astrophysics Programs. We thank the referee for the valuable suggestions to make the text more readable and quantifying some of the results.

Please wait… references are loading.
10.1088/0004-637X/745/1/76