Issue 19, 2018

An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

Abstract

Morphine (Mop) and methamphetamine (Met) are highly addictive drugs worldwide. Point-of-collection testing (POCT) for drug-of-abuse screening is important in abuse/rehabilitation clinics and law-enforcement agencies. We established an up-converting phosphor technology-based lateral flow assay (UPT-LFA) as a point-of-collection testing (POCT) method, namely Mop-UPT-LFA and Met-UPT-LFA, for the detection of morphine and methamphetamine without complicated sample pre-treatment, respectively, in saliva. The sensitivities of the Mop-UPT-LFA and the Met-UPT-LFA were 5 and 10 ng mL−1 with accurate quantitation of 5–100 ng mL−1 and 10–250 ng mL−1 for morphine and methamphetamine, respectively, for a detection time of 15 min. In reference to the detection limits of 20 and 25 ng mL−1 for morphine and methamphetamine, respectively, in the Driving Under the Influence of Drugs, Alcohol and Medicines (DRUID) program of the European Union, the percentage test/control (T/C) ratio of the UPT-LFA between 2 and 15 min reached 101% and 86%, and the UPT-LFA produced accurate qualitative results in 2 min for 100 simulated-saliva samples with the exception of a few weakly positive samples. The sample and sample treating buffer were mixed and added to the test strip, and the test was conducted 15 min later. Although we found no significant difference between the UPT-LFA quantitative test and the liquid chromatography tandem mass spectrometry (LC-MS) test, compared with the latter, the UPT-LFA was substantially faster and had higher detection efficiency. The UPT-LFA showed more accurate qualitative results than the LC-MS for 50 simulated-saliva samples. The ease of operation, high sensitivity, and accuracy of the UPT-LFA make it a valid candidate POCT method for drug-of-abuse screening.

Graphical abstract: An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

Supplementary files

Article information

Article type
Paper
Submitted
10 Apr 2018
Accepted
30 Jul 2018
First published
01 Aug 2018

Analyst, 2018,143, 4646-4654

An up-converting phosphor technology-based lateral flow assay for point-of-collection detection of morphine and methamphetamine in saliva

Q. Hu, Q. Wei, P. Zhang, S. Li, L. Xue, R. Yang, C. Wang and L. Zhou, Analyst, 2018, 143, 4646 DOI: 10.1039/C8AN00651B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements