Issue 7, 2010

Quantitative determination of protein stability and ligand binding using a green fluorescent protein reporter system

Abstract

Information about the stability of proteins is paramount to determine their optimal storage or reaction conditions. It is also essential to determine protein stability in high-throughput when screening for new or improved functions of proteins obtained from large mutant libraries. In drug discovery programs, monitoring of ligand-induced stabilization effects can be used to identify lead compounds in high-throughput. These studies require expensive biophysical instrumentation and large quantities of purified proteins. To address these issues, we developed a new method, using GFP as a reporter system to quantify the stability of a protein and its ligand-associated stabilization effects that requires neither special equipment nor extensive purification steps. Here, GFP is fused to a protein of interest (POI) through a linker and is used as a reporter system for protein unfolding and aggregation. The three POIs used in this study include the Ter-binding protein Tus, glycerol kinase and chloramphenicol acetyl transferase. The fluorescent fusion protein is subjected to irreversible thermal denaturation leading to formation of aggregates, which are eliminated by a centrifugation step. The residual fluorescence of the soluble fraction can be directly related to the stability of the POI and can be quantitatively monitored using a fluorescence plate reader. The GFP-based stability assay (GFP-Basta) was able to identify stabilizing compounds and afforded a new quantitative method for the screening and ranking of ligands for three different proteins. These applications are particularly useful for drug discovery, directed evolution, structural and functional genomics.

Graphical abstract: Quantitative determination of protein stability and ligand binding using a green fluorescent protein reporter system

Supplementary files

Article information

Article type
Paper
Submitted
29 Jan 2010
Accepted
23 Apr 2010
First published
07 May 2010

Mol. BioSyst., 2010,6, 1285-1292

Quantitative determination of protein stability and ligand binding using a green fluorescent protein reporter system

M. J. J. Moreau, I. Morin and P. M. Schaeffer, Mol. BioSyst., 2010, 6, 1285 DOI: 10.1039/C002001J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements