Issue 10, 2006

Solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry for the direct determination of traces of boron in biological materials using isotope dilution for calibration

Abstract

In this work, the possibilities of electrothermal vaporization-inductively coupled plasma mass spectrometry for the direct determination of B in biological samples have been critically evaluated, the goal always being to develop a fast and robust method that could be applied to different samples without significant modifications to the working protocol. Four reference materials of different nature (NIST SRM 1570a Trace Elements in Spinach Leaves, NIST SRM 1573a Tomato leaves, NIST SRM 1548a Typical Diet and BCR CRM 281 Rye Grass) were selected for this study. The importance of the use of NH4F·HF as chemical modifier for this element was demonstrated. By using this modifier, it was observed that the analyte can be vaporized and transported to the ICP in a more efficient way even at low vaporization temperatures (from 1000 °C onwards), resulting in a sensitivity increase (of a factor of approximately 10 compared with the vaporization in the absence of any modifier) while minimizing memory effects and carbon co-vaporization.The temperature program was adapted to permit the efficient use of this modifier when direct analysis of solid samples was intended. However, although well-defined B signal profiles could be attained also for the solid samples, evidence of signal suppression was observed. Under these conditions, the use of external calibration with aqueous standards would result in underestimated results (40–60% of the expected values). It was demonstrated that the use of isotope dilution can satisfactorily correct for these suppression effects, allowing accurate results to be obtained for all the samples under investigation. The most relevant figures of merit of the method finally developed are: RSD values ranging from 7 to 9%, a detection limit of 8 ng g−1, a sample throughput of 20–25 min per determination and a sample consumption of approximately 5 mg per determination.

Graphical abstract: Solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry for the direct determination of traces of boron in biological materials using isotope dilution for calibration

Article information

Article type
Paper
Submitted
28 Apr 2006
Accepted
17 Aug 2006
First published
01 Sep 2006

J. Anal. At. Spectrom., 2006,21, 1036-1044

Solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry for the direct determination of traces of boron in biological materials using isotope dilution for calibration

M. Resano, M. Aramendía and F. Vanhaecke, J. Anal. At. Spectrom., 2006, 21, 1036 DOI: 10.1039/B606118D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements