Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles

Abstract

Air exchange rates and interzonal flows are critical ventilation parameters that affect thermal comfort, air migration, and contaminant exposure in buildings and other environments. This paper presents the development of an updated approach to measure these parameters using perfluorocarbon tracer (PFT) gases, the constant injection rate method, and adsorbent-based sampling of PFT concentrations. The design of miniature PFT sources using hexafluorotoluene and octafluorobenzene tracers, and the development and validation of an analytical GC/MS method for these tracers are described. We show that simultaneous deployment of sources and passive samplers, which is logistically advantageous, will not cause significant errors over multiday measurement periods in building, or over shorter periods in rapidly ventilated spaces like vehicle cabins. Measurement of the tracers over periods of hours to a week may be accomplished using active or passive samplers, and low method detection limits (<0.025 μg m−3) and high precisions (<10%) are easily achieved. The method obtains the effective air exchange rate (AER), which is relevant to characterizing long-term exposures, especially when ventilation rates are time-varying. In addition to measuring the PFT tracers, concentrations of other volatile organic compounds (VOCs) are simultaneously determined. Pilot tests in three environments (residence, garage, and vehicle cabin) demonstrate the utility of the method. The 4 day effective AER in the house was 0.20 h−1, the 4 day AER in the attached garage was 0.80 h−1, and 16% of the ventilation in the house migrated from the garage. The 5 h AER in a vehicle traveling at 100 km h−1 under a low-to-medium vent condition was 92 h−1, and this represents the highest speed test found in the literature. The method is attractive in that it simultaneously determines AERs, interzonal flows, and VOC concentrations over long and representative test periods. These measurements are practical, cost-effective, and helpful in indoor air quality and other investigations.

Graphical abstract: Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles

Article information

Article type
Paper
Submitted
20 Oct 2005
Accepted
19 Dec 2005
First published
18 Jan 2006

J. Environ. Monit., 2006,8, 249-256

Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles

S. Batterman, C. Jia, G. Hatzivasilis and C. Godwin, J. Environ. Monit., 2006, 8, 249 DOI: 10.1039/B514899E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.