Main

Patients receiving intravenous conscious sedation for dentistry within the UK in general practice, community practice and the hospital service tend to receive incremental doses of intravenous midazolam administered by an operator-sedationist. Although there have been no major adverse events in dentistry the safety of such a regime has been questioned in other specialities with reports of up to 13% of patients desaturating to below 80% in the recovery area following sedation for endoscopy.1 Mortality has been reported in 0.05% of patients with approximately 60% of this being due to hypoxaemia.1,2,3,4 No such serious outcomes have been reported in dentistry.

In anaesthesia, target-controlled infusion (TCI) of propofol is gaining wide popularity. The system uses a pharmacokinetic model to achieve and maintain a selected target blood propofol concentration. The system has been further developed to incorporate a handset so that patients can titrate their own blood propofol concentrations to a sedation level appropriate to themselves. This combines the benefits of TCI with the well-established safety of a patient-controlled feedback loop and has been termed patient-maintained sedation (PMS).

Low dose propofol has been shown to have satisfactory anxiolytic properties when used as a sedative.5 It has been evaluated in a variety of intermittent bolus and infusion regimes.6,7,8

Patient-controlled sedation with propofol TCI has been shown to be safe and effective in reducing pre-operative anxiety levels when used to provide intra-operative sedation for patients undergoing surgery, with no patients becoming oversedated, premedication for day case patients and most recently in patients undergoing endoscopic examination.9,10,11

Propofol has several pharmacokinetic parameters that potentially make it a superior sedative agent to midazolam; more rapid onset and offset being two. However its routine use has been restricted to anaesthetists, as in high doses, general anaesthesia is produced with possible loss of the patient's patent airway.

Conscious sedation for minor oral surgery procedures is becoming increasingly popular as general anaesthesia becomes less so. In combination with local anaesthesia it potentially forms a pain-free and anxiety-free technique for both the patient and the surgical team. Any new drug delivery system must be carefully assessed for safety and efficacy in this specific environment.

This study assesses the first use of this patient-maintained sedation system using TCI propofol for oral surgery in 20 patients as a sedative technique for these procedures.

Materials and methods

The project was approved by the Hospital Ethics Committee. Twenty patients who were referred for oral surgery with conscious sedation were asked to participate in a study using patient-maintained propofol as the sedative technique. Recruitment was not selective and therefore included a range of anxiety levels from those phobic of dentistry to those anxious about surgical procedures. Written consent was obtained after a full explanation of the sedative technique and the surgery involved. Any patient considered fit for sedation was recruited. All patients were required to bring an escort and standard post-operative sedation instructions were given. These included no driving for twelve hours and resting at home for the rest of the day. Patients were not starved prior to treatment but were advised to have a light meal two hours before their appointment. Exclusion criteria included inability to use the handset, opioid use and severe respiratory disease.

Venous access was obtained and baseline observations were obtained of blood pressure, oxygen saturation and heart rate. Propofol TCI was delivered via a Graseby 3400 infusion pump controlled by a microprocessor system programmed with the pharmacokinetic data describing the distribution and elimination of propofol.10,12 The system displays the calculated effect-site, or the theoretical brain concentration, in addition to the target blood concentration of propofol, based on the patient's age and weight which are entered into the microprocessor. Connection of a handset to the microprocessor allows the patient to increase their target blood concentration of propofol (Figure 1).

Figure 1
figure 1

Patient maintained sedation equipment including handset.

Propofol (1% with lidocaine 20 mg per 50 ml to decrease pain on injection) was started at an initial target blood concentration of 1.5 μg/ml. When the microprocessor estimated the effect-site concentration to be 1.0 μg the target was reduced to 1.0 μg and the patient was instructed to 'double-press' the button as often as necessary. They were advised to sedate themselves to an appropriate level at which they would allow local anaesthesia to be administered.

Successful activation of the handset by double pressing the button within one second would increase the target blood concentration of propofol by 0.2 μg/ml. There was a lock-out period of two minutes during which no further target increases were possible. The maximum permissible target blood concentration of propofol was 3.0 μg/ml. If no successful demands were detected in six minutes the microprocessor would automatically reduce the target blood concentration by 0.2 μg/ml.

Once the patient considered themselves ready, they received a standard dental local anaesthetic (2% lidocaine with 1:80,000 adrenaline) and the surgery was carried out. They were advised to press the button at any stage if they wanted to be more sedated.

The patients were monitored throughout with pulse oximetry and measurements of heart rate and arterial oxygen saturation were recorded every five minutes. Blood pressure readings were recorded pre-operatively and prior to discharge. Any emergency interventions were noted. Patients were taken to a dedicated recovery area after their surgery was complete where they were monitored throughout with pulse oximetry by a trained dental nurse.

Once the patient was judged fit for discharge using a modified Romberg's test and by demonstrating a steady, unaided walk across the recovery room they completed a questionnaire designed to assess patient recall and satisfaction with the technique. The surgeon also completed a questionnaire regarding ease of undertaking the procedure and patient cooperation.

A note was made of start time, the time the patient-controlled button was enabled, surgery start time, surgery finish time and discharge time. The lowest recorded arterial oxygen saturation was also noted.

Results

Of the 20 patients, 19 completed their treatment satisfactorily and maintained a level of sedation which was both adequate for their anxiety control and for completion of the procedure. There were 16 female and four male patients. The mean age was 31 years with a range from 12 to 58. Fourteen patients were ASA I, five were ASA II and one was ASA III.

One of the twenty patients was a known epileptic and on completion of the surgery suffered three progressively shorter grand mal seizures with increasing time between each. She recovered spontaneously on each occasion and no measures other than monitoring and reassurance were required. She was transferred by ambulance to the local accident and emergency department where she was supervised for two hours. She suffered no further seizures and was discharged home without further problems. She could not be considered to have completed the study since it was impossible to complete the post-operative questionnaire.

All surgical procedures were carried out by the same surgeon and a variety of surgical procedures were performed (Table 1).

Table 1 Table 1

The mean procedure time was 15.4 minutes (4–30 mins). The mean time to local anaesthetic was 8.3 minutes (5–16 mins), to discharge was 47.4 mins (35–80 mins) and from end of procedure to discharge was 22.2 minutes (10–45 mins).

There were no cases of haemodynamic instability and the mean lowest oxygen saturation was 94%. One patient had a transient saturation of 87% which was corrected easily with supplemental oxygen at 2 l/min via nasal cannulae. This patient was the only ASA III patient in the study. The lowest arterial oxygen saturation for each patient is shown in Figure 2. There were no significant changes in heart rate or blood pressure.

Figure 2
figure 2

Lowest arterial oxygen saturation.

All twenty patients used the system satisfactorily to maintain a level of sedation which was adequate for their comfort and the completion of the surgical procedure. The recorded effect-site concentrations of propofol did not vary much immediately before the injection of local anaesthetic but showed a three-fold variation by the end of the surgical procedure. (Table 2).

Table 2 Table 2

Of the nineteen patients who completed a post-operative questionnaire all were happy with the sedation they received and would have the same system again. No patients reported nausea at any stage. Four experienced pain on injection of the propofol and six reported some pain during the procedure. Using a four point scale (no recall, not unpleasant, unpleasant, horrible) 18 patients found the whole procedure 'not unpleasant' and only one patient described it as 'unpleasant'. All patients recalled arriving in the dental surgery and the intravenous cannulation, 18 recalled injection of the local anaesthesia and seventeen reported remembering aspects of the surgical procedure. The patient who could not recall the local anaesthetic could recall the surgery.

Using a four point scale (easy, mild difficulty, difficult, very difficult) the surgeon rated three (16%) as 'easy', ten (53%) as 'mild difficulty' and six (32%) as 'difficult'. Using another four point scale (very good, good, average, minimal) the surgeon rated patient co-operation as 'very good' in sixteen cases (84%), 'good' in two cases (10%) and 'minimal' in one case (5%). The case rated as 'minimal' was a twelve-year-old for removal of four first molars.

A number of patients spontaneously volunteered when asked if they had any further comments that they liked the control they had over their sedation.

Discussion

Initial evaluation of this patient-maintained sedation system for oral surgery procedures has provided useful practical data. The system was used successfully and treatment was completed in all 20 patients. The median effect-site blood concentration required for adequate sedation was lower than in previous studies.9,10,11 No patient reached the maximum level of 3.0 μg/ml. Previous studies using endoscopy patients have reported levels of up to 4.5 μg/ml.9 This observation is almost certainly due to the good local anaesthetic blocks achievable for oral surgery procedures.

Sedation in dentistry tends to be provided with incremental doses of benzodiazepines. This technique is associated with a high degree of amnesia. The results from the present study suggest that a high proportion of patients treated with patient-maintained propofol sedation at these levels recall aspects of their procedure and more importantly they report it as not unpleasant. This may be a distinct advantage in trying to educate patients about the painless nature of modern dentistry. Previous reports, principally of endoscopy, have shown higher levels of amnesia and it has been suggested that this is dose related. Willingness of all patients in the present study to have a repeat procedure with the PMS technique would suggest that the recall of the patients in this study is a positive outcome. Although oral surgery tends to be a one-off procedure more general dentistry can often require repeat visits. The willingness to repeat the experience is a distinct advantage.

The system was found to be safe in that no patient suffered serious desaturation. The only patient with a saturation below 90% was promptly and easily treated with supplemental oxygen. In previous studies all patients have received supplemental oxygen,9,10,11 but our data would suggest this is unnecessary in our group of patients. No patients were oversedated and all maintained verbal contact throughout the procedure.

The one patient who did not complete the study did however complete her surgery and sedation. All the difficulties were postoperatively. Caution with propofol in epilepsy is well documented13 and our findings would suggest this system needs significant care in epileptic patients.

The surgeon rated cooperation as 'very good' in 84% of cases which is very encouraging. The only case in which cooperation was a problem was the only patient under 16 years old in the present study. This would fit with reports and should lead to caution in using the system in those under 16.

It is too early to recommend this system for wide use but initial experience has confirmed both surgeon and patient satisfaction were high. These results are encouraging and in combination with the increasing literature on the subject, the next stage is a prospective, randomised controlled trial of this new system against the more established technique of administering incremental doses of midazolam. The end-point is a safe and effective operator-sedationist system.