Abstract
Indoor air quality (IAQ) is much more crucial to human health than its atmospheric air quality counterpart. Improving indoor air environment requires investigating how different indoor air stability affects airflow trajectory. By presenting both manikin experiment and Computational Fluid Dynamics (CFD) simulation, we find that temperature background effect, i.e., indoor air stability, which is a measure of the nature or attribute of the capacity to keep the original or initial inertia force or inertia transmission state instead of turbulence diffusion or transmission restraining state, i.e., a kind of inertia stability, rather than a turbulence diffusion characteristic stability, is markedly affecting the interactive respiration process. So we define and derive a new parameter called G c number as a criterion to judge air stability. Furthermore, we find the phenomenon of inertia conjugation. Air stability and inertia conjugation, which named together as temperature background effect, work together on interactive respiration process. This work gives us a re-orientation of temperature difference agents and thus improves human being’s living environment.
Similar content being viewed by others
Introduction
Temperature difference affects atmospheric stability, which attributes to haze accumulation in human habitants. There are some literatures1,2,3,4,5,6,7,8,9,10,11,12 discussing atmospheric stability. However, in limited spaces, such as indoor environment, the same air stability problem still exists, which has a more serious impact on human health, for human beings spend most of their lifetime in interior spaces. Several studies have been made to identify the distribution of pollutants carried in patients’ expiratory airflow in different indoor environment13,14,15,16,17,18,19,20,21,22, and the effect of different indoor ventilation patterns on the transport characteristics of airborne expiratory droplets has also been studied23,24,25. In general terms, the phenomena of interactive respiration process characteristics under the temperature difference condition are interpreted as diffusion effects so far. Especially, Richardson Number (R i ) has been adopted to analyze the relationship between the temperature difference and turbulence diffusion term in atmosphere stability. Nowadays, air stability analysis includes static air stability and R i analysis that can help us understand the turbulence diffusion character, however, they can not explain the dispersing pattern in main-flow direction, i.e., actually a kind of conjugation phenomena. So, G c number is put forward in this study as a criterion to judge air stability and we need to rethink the nature of the air stability through interactive respiration process analysis here. We provide a genealogy of the temperature difference or small density difference effects (Fig. 1) and define G c as the ratio of the density difference (buoyancy) term of Bousinesq’s approximation to the convective inertia force (migrating inertia force) or acceleration term. G c number is set up by a dimensional analysis and order of magnitude analysis of differential equation based on principles of extended Reynolds Analogy and molecular transport, and is more suitable to reflect the impacts of inertia stability than R i number in Navier-Stokes or Euler Equations. Here we employ a simplified form of G c , i.e., G c is the number of the temperature or density difference source to convection or advection term along vertical or gravity direction. In order to make judgment criterion more clear, we also employ \({G}_{c}^{\text{'}}\) as a reciprocal form of G c , which is:
where A r is the Archimedes number, F r is the Froude number. When T t < T b , indoor air is in an unstable pattern, G c = −119.94 < 0, \({G}_{c}^{^{\prime} }=-8.3\times {10}^{-3} < 0\); when T t ≈ T b , indoor air is in a neutral pattern, G c = ∞, \({G}_{c}^{^{\prime} }=0\); when T t > T b , indoor air is in a stable pattern, G c = 119.94 > 0, \({G}_{c}^{^{\prime} }=8.3\times {10}^{-3} > 0\), and the results are in accordance with the judgments of the dry adiabatic lapse rate. And we also find another phenomenon that there is a kind of conjugation of air pollutant transmission process that along one direction, the pollutant transmission is intense, while along its conjugation direction, the pollutant transmission is weak. As air stability and G c number mentioned above, we prefer to rethink turbulence is a kind of continuing and compact inertia broken and lost. And the conjugation phenomenon is also a kind of inertia conjugation of transmission process as shown in Fig. 1. So, we name the air stability and conjugation transmission phenomena as the temperature background effect. The temperature background effects would vanish or be 0 when density difference is 0 under any air stability condition.
In order to investigate more details of the interactive respiratory process, we conduct both model experiment and numerical simulation. When exhaling velocity is 3.9 m/s, in exhaling process, the mainstream concentration in unstable case (G c = −119.94 < 0, \({G}_{c}^{^{\prime} }=-8.3\times {10}^{-3} < 0\)) in each position is significantly smaller than that in stable (G c = 119.94 > 0, \({G}_{c}^{^{\prime} }=8.3\times {10}^{-3} > 0\)) and neutral case (G c = ∞, \({G}_{c}^{^{\prime} }=0\)). As the mainstream has more intense turbulence diffusion in the vertical direction, the polluted area is larger than that of stable and neutral case where a stronger inertia effect exists. From the perspective of polluted area, in stable case (Fig. 2a3 ), inertia stability restrains the turbulence diffusion, so the polluted area in the vertical direction is the smallest, while in unstable case (Fig. 2a1 ), polluted area is larger because of a weaker inertia stability, of which we can make the most to design a better ventilation system to prevent indoor air pollution. It means that inertia transmission has a kind of directional character under stable air condition. From the perspective of the pollutants intensity, in stable case (Fig. 2a3 ), the smoke concentration maintains a high level, which is more harmful to the polluted area; in unstable case (Fig. 2a1 ), polluted area is larger and the smoke concentration is relatively low, so the harm is smaller.
When inhaling velocity is 3.9 m/s, in inhaling process, the mainstream intensity in unstable case (G c = −119.94 < 0, \({G}_{c}^{^{\prime} }=-8.3\times {10}^{-3} < 0\)) is significantly smaller than that in stable (G c = 119.94 > 0, \({G}_{c}^{^{\prime} }=8.3\times {10}^{-3} > 0\)) and neutral case (G c = ∞, \({G}_{c}^{^{\prime} }=0\)). As the smoke experiences a dispersive movement powered by temperature difference distribution which breaks the original or initial inertia state, it spreads around more easily. More stable indoor air can results in inhaling larger amount of pollutants with bigger inhaling velocity (Fig. 2b3 ). From the perspective of polluted area and pollutants intensity, experiment outcomes turn out to be the same with that of exhaling process.
When inhaling velocity is 1.7 m/s, in inhaling process, the characteristics of air stabilities of smoke transmission are the same with that under condition of 3.9 m/s inhaling velocity; but more smoke accumulates together in front of manikin face under the inhaling velocity is 1.7 m/s (Fig. 2b,c). It shows that holding breath can be an effective way to adjust smoke intensity inhaled. In unstable case (Fig. 2c1 ), smoke has the same upward movement trend instead of staying in inhalation area, leading to the low smoke intensity near manikin’s nose; in stable case (Fig. 2c3 ), smoke stays in inhalation area near the manikin’s nose with less dispersion because of the inertia stability, causing the highest smoke intensity. The result showed in neutral type (Fig. 2c2 ) lies between unstable and stable case.
Therefore, we can conclude that air stability or inertia stability plays a decisive role on indoor pollutants dispersion. Two facts are found in Fig. 2. First, airflow of the same exhaling velocity gets a further distance along mainstream direction in stable condition(Fig. 2a1,a2,a3 ). This is truly inertia transmission phenomena, which means the air stability is a kind of capacity of keeping the original or initial state of inertia force. Second, there is a kind of inertia accumulation effect when exhaling air flow reaches manikin because of the inertia stagnation and rebound (Fig. 2b), and the inertia accumulation effect is more obvious while indoor air maintains a more stable state (Fig. 2c). Furthermore, bigger inhaling velocity can make manikin gets more smoke or pollutants when air stability is stronger (Fig. 2b1,b2,b3 ). We think that, first of all, this is a kind of temperature difference or small density difference effect to convective or migrating inertia force. Air stability is a kind of map of temperature difference agent or density difference agent which affects the respiration airflow along two directions, and keeps the original or initial inertia force or inertia transmission state other than turbulence diffusion or transmission state. Secondly, there is a kind of conjugation phenomena that there is a pair or couple of conjugation transmission of pollutant when along the mainstream direction, convective or migrating transmission is stronger, i.e., the inertia transmission, and along the conjugation direction, the inertia transmission or turbulence diffusion is weak (the pairs of the arrows with yellow and green color in Fig. 2). That is also this kind of temperature difference or small density difference effect, i.e., the temperature background effect.
Indoor air stability is classified into three different types: unstable, neutral and stable type. Four CFD cases are conducted in this study to represent different indoor air stability types, with one case as a control experiment whose g = 0 m/s2.
We can find in Fig. 3 that the CFD simulation shows high consistency with experiment analysis above mentioned in Fig. 2. In unstable case (Fig. 3a1,a2,a3 ), G c = −119.94 < 0, \({G}_{c}^{^{\prime} }=-8.3\times {10}^{-3} < 0\), the turbulence diffusion is promoted, and smoke has a slower speed of convective or migrating inertia transmission and a smaller concentration; in stable case (Fig. 3b1,b2,b3 ), G c = 119.94 > 0, \({G}_{c}^{^{\prime} }=8.3\times {10}^{-3} > 0\), the convective or migrating inertia transmission is promoted, so smoke in the X axial direction has a farther moving distance and a higher concentration; when Gc number is 0 (Fig. 3a4,b4,c4 ), the characteristics of inertia force and turbulence diffusion are not affected by different indoor air distribution, and the transmission in 0 gravity case is always faster than that in neutral case when gravity exists, but the spread trajectory is basically the same, showing that if there is no gravity, there is no inertia transmission process variation.
When t = 10 s, the peak concentration in stable case is higher than that in unstable case (Fig. 4), which indicates that compared with the couple or conjugating phenomenon in Fig. 1, turbulence diffusion, inertia transmission and accumulation phenomenon in Fig. 2, there is a kind of directional effect of transmission process under stable condition.
Thus, we find a kind of inertia conjugation effect that along the mainstream direction, the inertia transmission is strong, while in the other direction the inertia transmission process is weak. When the convective inertia transmission touches obstacle or human body, the inertia accumulation is more obvious because of rebounding and stagnating when air stability or inertia stability is stronger. When gravity does not exist, the simulation results of three conditions are the same. It means if there is no gravity, there is no inertia transmission process variation. Therefore, this study re-structures air stability process as inertia stability process, it shows that temperature background condition affects the interactive respiration process. And this work lays a theoretical foundation to healthy environment control, and may purify human beings behavior in public situation.
Methods
There are three ways employed for temperature background effect via interactive respiration process. They are semi-analytical method, experiment analysis and CFD simulation, respectively. Amongst them, the experiment analysis used a size of 2.4 m × 1.8 m × 2.6 m room for performing air stability and a same size room is employed in CFD simulation.
References
Salby, M. L. Fundamentals of atmospheric physics. (Academic Press, California, 1995).
Barrat, R. Atmospheric dispersion modeling-an introduction to practical applications. (Earthscan Publications Ltd, Virginia, 2001).
Mohan, M. & Siddiqui, T. A. Analysis of Various Schemes for The Estimation of Atmospheric Stability Classification. Atmos. Environ. 32, 3775–3781 (1998).
Anfossi, D., Rizzab, U., Mangia, C., Degrazia, G. A. & Pereira Marques Filho, E. Estimation of the ratio between the Lagrangian and Eulerian time scales in an atmospheric boundary layer generated by large eddy simulation. Atmos. Environ. 40, 326–337 (2006).
Sharan, M., Rama Krishna, T. V. B. P. S. & Aditi On the bulk Richardson number and flux–profile relations in an atmospheric surface layer under weak wind stable conditions. Atmos. Environ. 37, 3681–3691 (2003).
Daoo, V. J., Panchal, N. S., Sunny, F. & Venkat Raj, V. Scintillometric measurements of daytime atmospheric turbulent heat and momentum fluxes and their application to atmospheric stability evaluation. Exp. Therm. Fluid. Sci. 28, 337–345 (2004).
Mavroidis, I., Andronopoulos, S. & Bartzis, J. G. Computational simulation of the residence of air pollutants in the wake of a 3-dimensional cubical building. The effect of atmospheric stability. Atmos. Environ. 63, 189–202 (2012).
Stoughton, T. E. & Miller, D. R. Vertical dispersion in the nocturnal, stable surface layer above a forest canopy. Atmos. Environ. 36, 3989–3997 (2002).
Bricard, P. & Friedel, L. Two-phase jet dispersion. J. hazard. mater. 59, 287–310 (1998).
Kruger, E. & Emmanuel, R. Accounting for atmospheric stability conditions in urban heat island studies: The case of Glasgow. UK, Landscape. Urban. Plan. 117, 112–121 (2013).
Luketa-Hanlin, A., Koopman, R. P. & Ermak, D. L. On the application of computational fluid dynamics codes for liquefied natural gas dispersion. J. hazard. mater. 140, 504–517 (2007).
Santos, J. M., Griffiths, R. F., Reis, N. C. Jr. & Mavroidis, I. Experimental investigation of averaging time effects on building influenced atmospheric dispersion under different meteorological stability conditions. Build. Environ. 44, 1295–1305 (2009).
Cheong, K. W. & Phua, S. Y. Development of ventilation design strategy for effective removal of pollutant in the isolation room of a hospital. Build. Environ. 41, 1161–1170 (2006).
Richmond, J., Eisner, A. D., Brixey, L. A. & Wiener, R. W. Transport of airborne particles within a room. Indoor Air. 16, 48–55 (2006).
Tian, Z., Tu, J., Yeoh, G. & Yeun, R. K. K. On the numerical study of contaminant particle concentration in indoor airflow. Build. Environ. 41, 1504–1514 (2006).
Tung, Y., Hu, S., Tsai, T. & Chang, I. An experimental study on ventilation efficiency of isolation room. Build. Environ. 44, 271–279 (2009).
Xu, Y., Yang, X., Yang, C. & Srebric, J. Contaminant dispersion with personal displacement ventilation, part I: base case study. Build. Environ. 44, 2121–2128 (2009).
Xu, C., Nielsen, P. V., Gong, G., Liu, L. & Jensen, R. L. Measuring the exhaled breath of a manikin and human subjects. Indoor Air. 25, 188–197 (2015).
Xu, C., Nielsen, P. V., Gong, G., Jensen, R. L. & Liu, L. Influence of air stability and metabolic rate on exhaled flow. Indoor Air. 25, 198–209 (2015).
Gong, G., Han, B., Luo, H., Xu, C. & Li, K. Research on the Air Stability of Limited Space. Int. J. Green Energy. 7, 43–64 (2010).
Wang, Y., Gong, G., Xu, C. & Yang, Z. Numerical investigation of air stability in space capsule under low gravity conditions. Acta. Astronaut. 103, 81–91 (2014).
Xu, C., Nielsen, P. V., Liu, L., Jensen, R. L. & Gong, G. Human exhalation characterization with the aid of schlieren imaging technique. Build. Environ. 112, 190–199 (2017).
Bjørn, E. & Nielsen, P. V. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air. 12, 147–164 (2002).
Nielsen, P. V. Control of airborne infectious diseases in ventilated spaces. Indoor Air. 6, 747–755 (2009).
Qian, H., Li, Y., Nielsen, P. V. & Hyldgaard, C. E. Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system. Build.Environ. 43, 344–354 (2008).
Acknowledgements
This work is supported by National Key Technology Support Program (No. 2015BAJ03B00), National Natural Science Foundation of China (No. 51378186) and the International Science and Technology Cooperative in Project of China (No. 2010DFB63830). We thank B. Han, H. Xie, H. Luo, Z. Yang, C. Xu, Y. Wang participate in our early research.
Author information
Authors and Affiliations
Contributions
G. Gong conceived the experiment; X. Deng designed and carried out the data analysis; G. Gong and X. Deng co-wrote the papers.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gong, G., Deng, X. Nature and characteristics of temperature background effect for interactive respiration process. Sci Rep 7, 8549 (2017). https://doi.org/10.1038/s41598-017-08871-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-08871-5
This article is cited by
-
Investigation of the effects of temperature and relative humidity on the propagation of COVID-19 in different climatic zones
Environmental Science and Pollution Research (2023)
-
Assessment of personal exposure to infectious contaminant under the effect of indoor air stability
Environmental Science and Pollution Research (2021)
-
Comparison of Mixing and Displacement Ventilation under Limited Space Air Stability Conditions in a Space Capsule
Microgravity Science and Technology (2020)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.