Introduction

The assessment of the microvascular function represents an important part in establishing the pathophysiology but also the risk stratification of cardiovascular disease (CVD)1. Indeed, endothelial dysfunction, one of the main culprits for the development of atherosclerosis, occurs much earlier at the microvascular than at the macrovascular level2,3. Dynamic retinal vessel analysis (DVA) was identified as a useful measure of early changes that signal endothelial dysfunction at the microvascular level. This method can also be used to identify risk for future cardiovascular pathologies in individuals at risk for4,5,6,7,8,9 or already suffering from CVD10,11. This is generally possible due to the fact that the retinal microvascular response to flicker provocation is, in part, dependent on nitric oxide (NO) release12, and compromised NO homoeostasis is known to be a key factor in endothelial dysfunction at all vascular levels.

The assessment of retinal microvessels is used in research but also in clinical practice for diagnosis and follow-up of various CVD, including hypertension13,14. Nevertheless, the overwhelming majority of protocols that look at retinal microvessels in the course of various CVD, use static imaging to detect abnormalities associated with various degrees of pathology. This is, however, useful only when CVD already established itself and not at earlier, pre-clinical stages. In order to determine the risk at earlier stages to allow preventive measures to be adopted, using the assessment of the retinal microvascular function represents a better alternative to structural imaging because it provides integrated and dynamic data to help establishing possible CVD risk.

In certain conditions that accelerate degradation of NO, such as high oxidative stress, microvascular dilation can be severely impaired15. In order to counteract such effects, the human body uses various anti-oxidative mechanisms including glutathione. Therefore, any condition associated with low levels of circulating glutathione result in a higher rate of oxidative reactions that contribute towards low NO bioavailability and, consequently, to an impaired microvascular function5,8,16,17. We have already shown that retinal microvascular dilation and constriction responses to stress levels are influenced by systemic antioxidant capacity, and circulating markers for CVD risk in healthy individuals with low to moderate cardiovascular risk7. Moreover, we have suggested that, by providing an integrated and dynamic analysis of vascular function that is, indeed, specific for each individual, retinal vessel reactivity could also be used for profiling a so-called individualized vascular risk for CVD7,8. Nevertheless, we have not tested this hypothesis in individuals with early stages of CVD. Therefore, the present study aims to study the retinal vascular function and its relationship with systemic anti-oxidative markers in individuals with various levels of early BP abnormalities as defined according to the 2018 European Society of Cardiology/European Society of Hypertension Guidelines18.

Methods

Study participants

Healthy individuals over the age of 30 were recruited through advertisements at the Vascular Research Laboratory, Aston University (Birmingham, UK), for inclusion in this prospective study. Ethical approval was sought from the relevant local ethics committee, and written informed consent was received from all participants prior to study enrolment. All experimental protocols were approved by the Aston University’s Ethics Committee and the study was designed and conducted in accordance with the tenets of the Declaration of Helsinki.

Study exclusion criteria were defined as the positive diagnosis of CVD, (coronary artery disease, heart failure, arrhythmia, stroke, transient ischaemic attacks), cerebrovascular disease, peripheral vascular disease, severe dyslipidaemia (defined as plasma triglycerides > 6.00 mmol/l or cholesterol levels > 7.00 mmol/l), diabetes, as well as other metabolic disorders or chronic diseases that required treatment. Individuals treated for systemic hypertension as well as those using other vasoactive medications such as dietary supplements containing vitamins or antioxidants and bronchodilators were also excluded from the study. Potential participants were also screened for ocular diseases and were excluded from the study if they had a refractive error of more than ± 3DS and more than ± 1DC equivalent, intra‐ocular pressure (IOP) greater than 21 mmHg, cataract or any other media opacities, as well as history of intra‐ocular surgery or any form of retinal or neuro‐ophthalmic disease affecting the ocular vascular system. Individuals with sings of hypertensive retinopathy at the initial fundus examination were also excluded.

All the above investigations are standard for our lab7,8,19,20,21.

General investigations

Participants who met the inclusion criteria were requested to complete a general health history questionnaire, also detailing daily diet, physical activity and alcohol consumption. All study‐related measurements were performed between 8 and 11 am following a 12‐hr overnight fast, which included refraining from alcohol and caffeine.

Standard anthropometric measures of height and weight were recorded to determine body mass index (BMI = weight/height²).

Blood pressure assessment and patients grouping

Measurements of BP and heart activity were first perdormed in-clinic. They were then confirmed using a computer‐operated ambulatory BP and electrocardiogram (ECG) monitor (Cardiotens‐01, Meditech Ltd, Budapest, Hungary). This device measures BP automatically using an oscillometric method and can store 1000 BP measurements. All subjects maintained their normal activity and were carefully instructed to complete a diary each time their activities changed, or when any chronic medication was taken. The 24‐h BP were later downloaded and analysed using the ‘Medibase’ software program (Meditech). The average systolic (SBP) as well as diastolic BP (DBP) measurements were calculated for the 24‐h interval and for both the active and passive periods of the recording. The average readings for SBP and DBP were then used to calculate the mean BP (MBP) using the formula: MBP = 2/3 × DBP + 1/3 × SBP. At least 80% of the programmed recordings were required for a diurnal curve to be considered in the present analysis22.

Using the 24-h SBP and DBP values, study participants were then stratified into four subcategories, ‘’optimal ‘’ “normal”, “high normal” and ‘’Grade I” as recommended by the 2018 European Society of Cardiology/European Society of Hypertension arterial hypertension Guidelines18.

Dynamic retinal vessel analysis

Retinal vessel reactivity was assessed using the dynamic retinal vessel analyser (DVA, IMEDOS GmbH, Jena, Germany) in accordance with an established protocol23. All measurements were performed in a temperature-controlled environment (22 °C) following pupil dilation with 1% Tropicamide (Chauvin Pharmaceuticals Ltd, UK) and were taken from the inferior temporal vessel branches approximately one and a half disc diameters from the optic nerve head of one unselected eye. The flicker stimulation protocol involves a 350‐second continuous diameter recording along short 1 mm sections of the retinal vasculature, the duration of which included a 50‐second baseline measurement followed by three successive cycles of flicker stimulation distinguished as a 20‐second stimulus (opto‐electronically generated at 12.5 Hz) and an 80‐second recovery period (still illumination)7. The following vessel reactivity and time-course parameters were determined for each flicker cycle and then averaged over the 3 cycles, with the artery and vein regarded separately as follows: the average baseline diameter and range of maximum and minimum baseline vessel diameters (baseline diameter fluctuation, BDF); the maximum vessel dilation diameter during flicker stimulation expressed as a percentage change relative to baseline diameter (MD%) and the time taken in seconds to reach the maximum diameter (tMD); the maximum vessel constriction diameter during the postflicker recovery period expressed as a percentage change relative to baseline diameter (MC%) and the time taken in seconds to reach the maximum vessel constriction diameter (tMC); the overall dilation amplitude (DA) calculated as the difference between MD and MC; and the baseline-corrected flicker response (BCFR) used to describe the overall dilation amplitude after normalizing for fluctuations in baseline diameters (DA-BDF). In addition, the arterial (A) and venous (V) dilation slopes (SlopeAD/VD = (MD − baseline diameter)/tMD) and constriction slopes (SlopeAC/VC = (MC − MD)/tMC) were also calculated (Fig. 1)6.

Figure 1
figure 1

Graphical presentation of the dynamic vessel response profile displaying the parameters calculated and used in analysis. (DA) calculated as (MD-MC). (MD%) calculated as the percent increase from baseline to MD. (MC%) calculated as the percent constriction below baseline following MD42.

Figure 2
figure 2

Comparison of retinal arterial response profile across groups. AU, arbitrary units; BDF, baseline diameter fluctuation calculated as the maximum range in vessel diameter during first 30 seconds of baseline readings; MD%, calculated as the percentage change in vessel diameter from baseline to maximum following onset of flicker; tMD, time to reach maximum diameter during flicker; tMC, time to reach maximum constriction post flicker; SlopeAC,,calculated as (MC-MD)/(tMC).

Biomarker assays

Bloods samples drawn from the ante‐cubital fossa vein on the morning of the appointment were collected into standard EDTA Vacutainer® tubes and assessed immediately for fasting triglycerides (TG), plasma total cholesterol (CHOL) and high‐density lipoprotein cholesterol (HDL‐C) using the Reflotron Desktop Analyser (Roche Diagnostics, UK). Low‐density lipoprotein cholesterol (LDL‐C) values were calculated as per the Friedewald equation24.

Measurement of GSH and oxidized glutathione (GSSG)

Initial processing of blood GSH and GSSG levels were assessed by the GSH recycling assay as detailed previously21. Briefly, a 30 μl aliquot of EDTA blood was pretreated with 33.3 μl of 100 mg/ml 5‐sulfosalicylic acid (SSA), 936.7 μl sodium phosphate buffer (pH 7.5) to release GSH via cellular disruption and protein precipitation. The sample was centrifuged at 13, 000 rpm for 5 min, and the supernatant was stored at −80 °C for further analyses. Based on previous reports of sample stability, assays were conducted within 2 months of collection25. The GSH levels [t‐GSH – (2 × GSSG)] and the redox index (defined as the GSH/GSSG ratio) were determined according to an established enzymatic recycling assay26,27 that involves the oxidation of GSH by the sulphydryl reagent 5,5′‐dithio‐bis(2‐nitrobenzoic acid) (DTNB) to form the yellow derivative 5′‐thio‐2‐nitrobenzoic acid (TNB), which can be measured spectrophotometrically at 412 nm.

Any GSSG formed was recycled to GSH by glutathione reductase (GSR) in the presence of nicotinamide adenine dinucleotide phosphate‐oxidase (NADPH). For the measurement of GSSG levels, samples were pretreated with, 2‐vinylpyridine (2VP) to derivatize GSH without interfering with GSR reaction. For the determination of analyte concentrations in the samples, GSH standards were prepared from 0 to 80 μm in increments of 20 μm and GSSG standards were prepared from 0 to 10 μm in increments of 1 μm with the same final concentrations of SSA (1%) as in the samples. Standard curves were generated using a linear regression program (Microsoft Excel, Microsoft Corporation, USA). As the microplates were read at 0, 1, 2, 3 and 5 min, the change in optical density or absorbance at different times points expressed against GSH or GSSG concentration (net reaction rate = slope * GSH or GSSG concentration + intercept) was used to determine GSH or GSSG concentrations in the samples (net rate − intercept/slope * dilution factor). The blood GSH and GSSG concentrations measured in this study were in good agreement with literature data in control patients in the ranges of 150–1500 μm and 1–500 μm, respectively5,8,23,28,29. This suggests that the experimental conditions reported in this study are suitable for the analysis of total glutathione and glutathione disulphide concentrations in whole blood. The validity and reliability of the spectrophotometric method of detection has also previously been established30.

Sample size and statistical analysis

Based on previous studies, a change of 30% with a SD of 2.5% in retinal vessels reactivity was shown to be significant8,31. As the study design was multifactorial in nature, it was calculated that a sample size of n = 42 in each group was sufficient to provide 95% power at an alpha level of 0.05.

All analyses were performed using Statistica® software (version 13.3, StatSoft Inc., Tusla, OK, USA). Distributions of continuous variables were determined by the Shapiro-Wilks test. In cases where normality of the data could not be confirmed appropriate data transformations were made or non-parametric statistical alternatives were used. Univariate associations were determined using Pearson’s (normally distributed data) or Spearman’s method (non-normally distributed data), and forward stepwise regression analyses were performed to test the influence of clinical parameters and circulating markers on the measured vascular reactivity variables. Differences between groups were subsequently assessed using one-way ANOVA or ANCOVA, as appropriate, followed by Tukey’s post hoc analysis. P-values of <0.05 were considered significant5,6,7.

Results

A total number of 218 participants were initially screened for study inclusion of which 17 individuals were excluded based on the quality of retinal vascular image analysis. The remaining 201 participants (93 men and 108 women) were included in the final analysis and classified in one of 4 study groups using the current ESC/ESH Guidelines: group 1 (optimal BP: 56 individuals 22 men and 34women), group 2 (normal BP: 54 individuals, 35 men and 19 women), group 3 (high normal BP: 44 individuals, 28 men and 16 women) and group 4 (grade 1 hypertension: 47 individuals, 28 men and 19 women).

Table 1 shows the clinical characteristics of the study population. Although the first group were significantly younger than group 4, there were no statistically significant differences between the study groups with regards to gender, BMI and circulating levels of glucose, t-Chol and HDL-Chol between the study groups (all p > 0.05). Nevertheless, as expected, there were statistically significant differences between the 4 study groups with regards to SBP, DBP and MBP (all p < 0.0001). In addition, individuals classed as high normal and grade 1 hypertension demonstrated higher levels of circulating TG (p = 0.0021, ANCOVA) and GSSG (p = 0.0111, ANCOVA) and lower levels of GSH (p = 0.0060, ANCOVA). Moreover, individuals classed as grade 1 hypertension demonstrated higher levels of LDL-C (p = 00265, ANCOVA) than the rest of the study groups.With regards to arterial and venous retinal vascular reactivity parameters as characterized in Tables 2 and 3, all values reported are based on averaged data across three flicker cycles with the artery and vein regarded separately.With regards to the measured retinal arteriolar parameters, after controlling for all influential covariates identified by multivariate regression analysis, and independent of age, individuals classed as grade 1 hypertension demonstrated significantly higher BDF (p = 0.0012, Fig. 2), MD% (p = 0.0007, Fig. 2), tMC (p = 0.0003, Fig. 2) and lower SlopeAC (p = 0.0131, Fig. 2) than the rest of the study groups. In addition, individuals classed as high normal and grade 1 hypertension also demonstrated higher tMD than individuals classed as optimal or normal (p < 0.0001, Fig. 2).There were no significant differences between participants with regard to measured venous parameters (all p > 0.05, Table 3).

Table 1 Summary of the systemic characteristics of the study participants.
Table 2 Summary of retinal arterial vascular function parameters.
Table 3 Summary of retinal venous vascular function parameters.

Correlations between vascular and systemic circulatory parameters

Univariate analysis revealed that the whole blood GSH levels correlated significantly and negatively with SBP, DBP and MBP values in all participants (r = −0.25, p = 0.0010; r = −0.17, p = 0.0350 and r = −0.22, p = 0.0050, as well as with MBP values in those classed as high normal and with grade 1 hypertension (r = −0.38, p = 0.0290) but not in those classed as having optimal or normal BP (p > 0.05). In addition, the levels of whole blood GSSG correlated significantly and positively with SBP, DBP and MBP values in all participants (r = 0.16, p = 0.0410; r = 0.17, p = 0.0330 and r = 0.18, p = 0.0220,but not in any groups separately (all p > 0.05).

There were no correlations between the levels of GSH and retinal vascular parameters in any of the study groups (all p > 0.05). However, GSSG levels correlated significantly and positively with artery BDF (r = 030, p = 0.0370) and negatively with SlopeAC only in individuals classed as having an optimal BP level (r = −0.37, p = 0.0200).

Discussions

In the present study, we have examined the differences in retinal vascular function between individuals with normal and early stages of abnormal BP according to the current ESC/ESH guidelines. We have also looked at the relationship between systemic BP, retinal vessel reactivity and systemic antioxidant defense capacity in each of the study groups. Our results showed, for the first time, that individuals graded as having high normal BP values or grade 1 hypertension displayed abnormal dilatory and constrictor responses to flicker light stimulation in retinal arteries but not in the retinal veins when compared to those classed as having optimal or normal BP values.

Hypertension is a polygenic disease; however, endothelial dysfunction and enhanced oxidative stress are among the established modifiable risk factors for this disease32. Alteration of vascular reactivity characterized by augmented contractility and impaired relaxation is a prominent feature in hypertension. Moreover, in essential hypertension, NO availability is reduced earlier, resulting in early vascular endothelial dysfunction33. Indeed, our relatively young patients with high normal BP and grade 1 hypertension according to the current ESC/EHS guidelines demonstrated abnormal retinal microvascular dilation and constriction after stimulation with flickering light.

It has already been demonstrated that pre-hypertension is associated with retinal microvascular alterations early in life34. Nevertheless, it seems that these alterations can also be identifiable at BP values previously considered within normal values. Indeed, our study participants classed as having high normal BP values and without additional risks for CVD, have also exhibited signs of microvascular dysfunction at the retinal level. At these BP values, treatments for hypertension are not yet indicated; however, in the light of the above observations, additional measures to prevent further damage may be considered. Moreover, ESC/ESH also recommends treating at lower BP levels in very high-risk patients with a high–normal BP and established CVD18. Nevertheless, the potential impact of pushing for an earlier diagnosis is multiple, including pressures on the health system and economy35. Therefore, a careful consideration should be given to the actual benefits of treatment in each individual separately, rather than in a given risk category. At present, all the new biomarkers for CVD risk drive the shift towards personalized medicine. Therefore, due to its personalised approach, retinal vessel reactivity can be used for profiling individualized vascular risk by providing an integrated and dynamic analysis of vascular function specific for each individual, therefore, aiding a personalised management of abnormal BP values.

As already mentioned above, increased oxidative stress is an important risk factor for the development of hypertension. Among other defense mechanisms, glutathione represents a major redox buffer36. It has been already shown that GSH significantly lower and the GSSG is higher in the red blood cells in patients with hypertension but not in normal individuals37. Similarly, we have also shown that whole-blood GSH level were lower and GSSG level were higher in individuals classed as high normal and grade 1 hypertension. These results show for the first time that such changes may actually occur at a much earlier stage than previously noticed and go in parallel in the changes observed in the retinal microvasculature, confirming that, in the presence of abnormal BP levels, the pathological inhibition of vascular relaxation involves not only NO production by endothelial cells but also a glutathione-dependent bioavailability of NO38. In addition, we also demonstrated that GSSG correlated with retinal arterial baseline and constriction characterisation parameters only in individuals with optimal BP levels and without additional CVD risks. It is very interesting that, although the levels of antioxidative products were abnormal in individuals with higher BP levels, the link between redox status and retinal vascular reactivity was lost in these groups. This observation links, however, to our previous results in in individuals with low to moderate CVD risk, indicating that in addition to other processes, antioxidant mechanisms support normal NO levels during flicker provocation at the retinal microvascular level7. However, in the present study we could not identify such relationship in individuals with higher levels of BP. As the effects of radical oxygen species (ROS) on vascular tone is dependent upon the concentration and type of species, as well as on the type of vascular beds and various experimental conditions39, it is possible that these effects were not visible in our specific setup. Indeed, it has been proposed that there is a lack of sensitive methods to accurately evaluate the oxidative stress in the human cardiovascular system, especially when it comes to establishing the role redox stress in the small artery vasculopathy of human hypertension40.

Conclusions

Abnormalities of microvascular dysfunction may be an important risk factor for systemic hypertension. In addition, excessive oxidative stress is associated results in cardiovascular diseases by impairing endothelial function and, consequently, microvascular dysfunction. This complex interlink cannot be ignored and measures to address both dysfunctions should be applied. This is especially important since, despite significant advancement in understanding the pathophysiology of human hypertension and the large number of antihypertensive drugs, strict BP control is still proving insufficient for the prevention of future vascular complications, the so-called “Hypertension Paradox”41. Therefore, more research is necessary to develop specific mechanism-based personalised therapies that will address the vascular redox pathobiology40. These therapies will possibly need to be applied at much earlier stage when abnormalities are only functional and can still be reversed.