Abstract
The potential use of vertical cavity surface emitting laser (VCSEL) arrays for applications in cell analysis and tissue engineering is investigated by means of parallel optical trapping and active manipulation of biological cells on microfluidic chips. The simultaneous and independent transport of nine cells using a 3×3 array of VCSELs has been demonstrated experimentally; indicating that larger 2-dimensional array transport using individually addressable tweezers is achievable with VCSEL array devices. The transport properties of VCSEL tweezers have been investigated for various types of cells including 3T3 Murine fibroblasts, yeast, rat primary hepatocytes and human red blood cells. Due to the low relative index of refraction between the biological cell and surrounding medium and the relatively low optical power available with present VCSELs, the Laguerre-Gaussian laser mode output of the VCSEL is more favorable to use in an optical tweezer since the highest intensity is located at the outer ring of the optical aperture, producing stronger optical confinement at lower power levels. For larger biological cells or cells with a lower relative index of refraction, the power limitations of a single VCSEL were overcome through the binning of several VCSELs together by combining the outputs of a sub-array of VCSELs into a collective optical tweezer. A comprehensive analysis and simulation of how the VCSELs’ pitch and output beam divergence influence the operation of the resultant optical tweezer array is presented along with our experimental data. Employing the methods of parallel array transport and the binning of multiple VCSEL outputs, allows for the manipulation and spatial arrangement of different types of cells in a co-culture so as to facilitate the formation of engineered tissues.
Similar content being viewed by others
References
A. Ashkin, Biophys. J. 61, 569-582 (1992).
A. Ashkin, J.M. Dziedzic, J.E. Bjorkholm, and S. Chu, Opt. Lett. 11, 288-290 (1986).
S. Bhatia and C. Chen, Biomedical Microdevices 2(2), 131-144 (1999).
S. Bhatia, M.L. Yarmush, and M. Toner, in Methods in Molecular Medicine: Tissue Engineering Methods and Protocols, eds. J.R. Morgan and M. Yarmush (Humana Press, New Jersey, 1998), pp. 349-363.
S.M. Block, Nature 360, 493-495 (1992).
S.M. Block, in Noninvasive Technologies in Cell Biology, eds. J.K. Foskett and S. Grinstein (Wiley, New York, 1990), pp. 375-402.
L. Breckenridge, P. Clark, P. Connolly, A.S.G. Curtis, J.A.T. Dow, R. Wilson, R. Lind, and C.D.W. Wilkinson, in Synthetic Microstructures in Biological Research, eds. J.M. Schnur, M. Peckerar, and H.M. Stratton (Plenum, New York, 1992), pp. 201-206.
E. Delamarche, A. Bernard, H. Schmid, B. Michel, and H. Biebuyck, Science 276, 779-781 (1997).
D.C. Duffy, R.J. Jackman, K.M. Vaeth, K.F. Jensen, and G.M. Whitesides, Adv. Mater. 11(7), 546 (1999).
J.C Dunn, R.G. Tompkins, and M.L. Yarmush, Biotechnol. Prog. 7, 237-245 (1991).
R.A. Flynn, A.L. Birkbeck, M. Gross, M. Ozkan, B. Shao, M.M. Wang, and S.C. Esener, Sens. Actuators B 87(2), 241-245 (2002).
A. Folch, A. Ayon, O. Hurtado, M.A. Schmidt, and M. Toner, J. Biomech. Eng. 121(1), 28-34 (1999).
A. Folch, B.H. Jo, D. Beebe, M. Toner and O. Hurtado, J. Biomed. Mater. Res. 52(2), 346-353 (2000).
A. Folch and M.A. Smith, J. Microelectromech. Syst. 8(1), 85-89 (1999).
E. Hecht, in Hect Optics 2nd Ed., ed. B. Spatz (Addison-Wesley, Massachusetts, 1990), pp. 211-240.
K. Hirano, Y. Baba, Y. Matsuzawa, and A. Mizuno, Appl. Phys. Lett. 80(3), 515-517 (2002).
R.J. Jackman, J.L. Wilbur, and G.M. Whitesides, Science 269(5224), 664-666 (1995).
O. Kibar, R.A. Flynn, and S.C. Esener, OSA Topical Mtg. Spatial Light Modulators Tech. Digests 49-51 (1999).
I. Martin, B. Obradovic, S. Treppo, A.J. Grodzinsky, R. Langer, L.E. Freed, and G. Vunjak-Novakovic, Biorheology 37(1–2), 141-147 (2000).
A.D. Mehta, M. Rief, J.A. Spudich, A. Smith, and R.M. Simmons, Science 283, 1689-1695 (1999).
Y. Ogura, K. Kagawa, and J. Tanida, Appl. Opt. 40(30), 5430-5435 (2001).
A.T. O'Neil and M.J. Padgett, Opt. Commun. 193, 45-50 (2001).
M. Ozkan, T. Pisanic, J. Scheel, C. Barlow, S.C. Esener, and S. N. Bhatia, The Special Issue of Langmuir on “The Biomolecular Interface” 19(5), 1532-1538 (2003).
M. Ozkan, M.M. Wang, and S.C. Esener, Proc. OSA Optics in Computing, OtuC1–2 (2001).
A. Schwarz, J.S. Rossier, E. Roulet, N. Mermod, M.A. Roberts, and H.H. Girault, Langmuir 14(19), 5526-5531 (1998).
P.O. Seglen, Methods Cell Biol. 13, 29-83 (1976).
N.B. Simpson, D. McGloin, K. Dholakia, L. Allen, and M.J. Padgett, J. Mod. Opt. 45, 1943-1949 (1998).
I.A. Vorobjev, H. Liang, W.H. Wright, and M.W. Berns, Biophys. J. 64, 533-538 (1993).
M.M. Wang, M. Ozkan, P. Wen, M.D. Sanchez, E.P. Ata, C. Ozkan, O. Kibar, and S.C. Esener, Proc. Spie 4260, 68-73 (2001).
M.M. Wang, M. Ozkan, E. Ata, P. Wen, M.D. Sanchez, C.S. Ozkan, O. Kibar, and S. C. Esener, BiOS 2001 (2001).
W.H. Wright, G.J. Sonek, Y. Tadir, and M.W. Berns, IEEE J.Quantum Electro. 26(12), 2148-2157 (1990).
Y.N. Xia and G.M. Whitesides, Annu. Rev. Mater. Sci. 28, 153-184 (1998).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Birkbeck, A.L., Flynn, R.A., Ozkan, M. et al. VCSEL Arrays as Micromanipulators in Chip-Based Biosystems. Biomedical Microdevices 5, 47–54 (2003). https://doi.org/10.1023/A:1024463316562
Issue Date:
DOI: https://doi.org/10.1023/A:1024463316562