Abstract
A microbial fuel cell type of biosensor was used to determine the biochemical oxygen demand (BOD) of wastewater. The biosensor gave a good correlation between the BOD value and the coulomb produced. The BOD sensor has been operated for over 5 years in a stable manner without any servicing. This is much longer that that of previously reported BOD biosensors.
Similar content being viewed by others
References
Chee GJ, Nomura Y, Karube I (1999) Biosensor for the estimation of low biochemical oxygen demand. Anal. Chem. Acta 379: 185–191.
Eaton AD, Clesceri LS, Greenberg AE (1995) Standard Methods for the Examination of Water and Wastewater, 19th edn. Washington, DC: American Public Health Association.
Gil GC, Chang IS, Kim BH, Kim M, Jang JK, Park HS, Kim HJ (2003) Operational parameters affecting the performance of a mediator-less microbial fuel cell. Biosens. Bioelectron., in press.
Hikuma M, Suzuki H, Yasuda T, Karube I, Suzuki S (1979) Amperometric estimation of BOD by using living immobilized yeast. Eur. J. Appl. Microbiol. Biotechnol. 8: 289–297.
Hyun CK, Tamiya E, Takeuchi T, Karube I, Inoue N (1993) Novel BOD sensor based on bacterial luminescence. Biotechnol. Bioeng. 41: 1107–1111.
Kim BH, Kim HJ, Hyun MS, Park DH (1999a) Direct electrode reaction of Fe(III) reducing bacterium, Shewanella putrefaciens. J. Microbiol. Biotechnol. 9: 127–131.
Kim HJ, Hyun MS, Chang IS, Kim BH (1999b) A microbial fuel cell type lactate biosensor using a metal-reducing bacterium, Shewanella putrefaciens. J. Microbiol. Biotechnol. 9: 365–367.
Kim HJ, Park HS, Hyun MS, Chang IS, Kim M, Kim BH (2002) A mediator-less microbial fuel cell using a metal reducing bacteirium, Shewanella putrefaciens. Enzyme Microb. Technol. 30: 145–152.
Kim MN, Kwon HS (1999) Biochemical oxygen demand sensor using Serratia marcescens LSY 4. Biosens. Bioelectron. 14: 1–7.
Liu J, Mattiasson B (2002) Microbial BOD sensors for wastewater analysis. Water Res. 36: 3786–3802.
Liu J, Bjornsson L, Mattiasson B (2000) Immobilised activated sludge based biosensor for biochemical oxygen demand measurement. Biosens. Bioelectron. 14: 883–893.
Preininger C, Klimant I, Wolfbeis OS (1994) Optical fiber sensor for biological oxygen demand. Anal. Chem. 66: 1841–1846.
Qian Z, Tan TC (1998) Response characteristics of a dead-cell BOD sensor. Water Res. 32: 801–807.
Reynolds DM, Ahmad SR (1997) Rapid and direct determination of wastewater BOD values using a fluorescence technique. Water Res. 31: 2012–2018.
Riedel K, Renneberg R, Kühn M, Scheller F (1988) A fast estimation of biochemical oxygen demand using microbial sensors. Appl. Microbiol. Biotechnol. 28: 316–318.
Sasaki Y, Abe N, Takeuchi S, Takahashi F (1995) BOD sensor using magnetic activated sludge. J. Ferment. Bioeng. 80: 300–303.
Tan TC, Wu C (1999) BOD sensors using multi-species living or thermally killed cells of a BIOSEED microbial culture. Sensor. Actuator. B54: 252–260.
Tan TC, Li F, Neoh KG (1993) Measurement of BOD by initial rate of response of a microbial sensor. Sensor. Actuator. B10: 137–142.
Yang Z, Suzuki H, Sasaki S, McNiven S, Karube I (1997) Comparison of the dynamic transient-and steady-state measuring methods in a batch type BOD sensing system. Sensor. Actuator. B45: 217–222.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, B.H., Chang, I.S., Cheol Gil, G. et al. Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell. Biotechnology Letters 25, 541–545 (2003). https://doi.org/10.1023/A:1022891231369
Issue Date:
DOI: https://doi.org/10.1023/A:1022891231369