Hostname: page-component-8448b6f56d-cfpbc Total loading time: 0 Render date: 2024-04-18T07:06:52.863Z Has data issue: false hasContentIssue false

Fit Characteristics of N95 Filtering Facepiece Respirators and the Accuracy of the User Seal Check among Koreans

Published online by Cambridge University Press:  18 January 2018

Yu Jung Huh
Affiliation:
Department of Nursing, Armed Forces Capital Hospital, Seongnam, Republic of Korea
Hye Min Jeong
Affiliation:
Office of Infection Control, Armed Forces Capital Hospital, Seongnam, Republic of Korea
Juhye Lim
Affiliation:
Department of Nursing, Armed Forces Capital Hospital, Seongnam, Republic of Korea
Ha Yan Park
Affiliation:
Department of Nursing, Armed Forces Capital Hospital, Seongnam, Republic of Korea
Min Young Kim
Affiliation:
Department of Nursing, Armed Forces Capital Hospital, Seongnam, Republic of Korea
Hong Sang Oh
Affiliation:
Office of Infection Control, Armed Forces Capital Hospital, Seongnam, Republic of Korea Division of Infectious Diseases, Department of Medicine, Armed Forces Capital Hospital, Seongnam, Republic of Korea.
Kyungmin Huh*
Affiliation:
Office of Infection Control, Armed Forces Capital Hospital, Seongnam, Republic of Korea Division of Infectious Diseases, Department of Medicine, Armed Forces Capital Hospital, Seongnam, Republic of Korea.
*
Address correspondence to Kyungmin Huh, MD, MSc, Division of Infectious Diseases, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea (kyungminhuh.id@gmail.com).

Abstract

Adequate facepiece fit of N95 filtering facepiece respirators (FFRs) is crucial for optimal protection against airborne pathogens. The quantitative fit test (QNFT) pass rates of the 4 N95 FFR models commonly used in Korea were below 50%. Male sex was identified as a single independent predictive factor for QNFT pass.

Infect Control Hosp Epidemiol 2018;39:104–107

Type
Concise Communications
Copyright
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

a

(Present affiliation: Division of Infectious Diseases, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea [K.H.].)

References

REFERENCES

1. Han, DH, Choi, KL. Facial dimensions and predictors of fit for half-mask respirators in Koreans. AIHA J (Fairfax, VA) 2003;64:815822.CrossRefGoogle ScholarPubMed
2. Derrick, JL, Chan, YF, Gomersall, CD, Lui, SF. Predictive value of the user seal check in determining half-face respirator fit. J Hosp Infect 2005;59:152155.Google Scholar
3. Zhuang, Z, Bradtmiller, B, Shaffer, RE. New respirator fit test panels representing the current U.S. civilian work force. J Occup Environ Hyg 2007;4:647659.CrossRefGoogle ScholarPubMed
4. Bergman, M, Zhuang, Z, Brochu, E, Palmiero, A. Fit assessment of N95 filtering-facepiece respirators in the US Centers for Disease Control and Prevention strategic national stockpile. J Int Soc Respir Prot 2015;32:5064.Google Scholar
5. McMahon, E, Wada, K, Dufresne, A. Implementing fit testing for N95 filtering facepiece respirators: practical information from a large cohort of hospital workers. Am J Infect Control 2008;36:298300.CrossRefGoogle ScholarPubMed
6. Yu, Y, Jiang, L, Zhuang, Z, et al. Fitting characteristics of N95 filtering-facepiece respirators used widely in China. PLoS One 2014;9:e85299.Google Scholar
7. Kim, H, Baek, JE, Seo, HK, et al. Assessing real-time performances of N95 respirators for health care workers by simulated workplace protection factors. Ind Health 2015;53:553561.CrossRefGoogle ScholarPubMed
8. Lam, SC, Lee, JK, Yau, SY, Charm, CY. Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators. J Hosp Infect 2011;77:252256.CrossRefGoogle ScholarPubMed
9. Oestenstad, RK, Elliott, LJ, Beasley, TM. The effect of gender and respirator brand on the association of respirator fit with facial dimensions. J Occup Environ Hyg 2007;4:923930.CrossRefGoogle ScholarPubMed
10. Niezgoda, G, Kim, JH, Roberge, RJ, Benson, SM. Flat fold and cup-shaped N95 filtering facepiece respirator face seal area and pressure determinations: a stereophotogrammetry study. J Occup Environ Hyg 2013;10:419424.CrossRefGoogle ScholarPubMed
Supplementary material: File

Huh et al. supplementary material 1

Appendix

Download Huh et al. supplementary material 1(File)
File 3 MB
Supplementary material: Image

Huh et al. supplementary material

Supplementary figure 1

Download Huh et al. supplementary material(Image)
Image 25.3 MB
Supplementary material: Image

Huh et al. supplementary material

Supplementary figure 2

Download Huh et al. supplementary material(Image)
Image 1.1 MB
Supplementary material: Image

Huh et al. supplementary material

Supplementary figure 3

Download Huh et al. supplementary material(Image)
Image 1.1 MB
Supplementary material: Image

Huh et al. supplementary material

Supplementary figure 4

Download Huh et al. supplementary material(Image)
Image 925.7 KB