The influence of irradiation potential on the degree of conversion and mechanical properties of two bulk-fill flowable RBC base materials

https://doi.org/10.1016/j.dental.2013.05.008Get rights and content

Abstract

Objective

To assess the depth of cure claims of two bulk-fill flowable RBC bases (SDR and x-tra base) using Fourier transform infrared (FTIR) spectroscopy, biaxial flexure strength (BFS), and Vickers hardness number (VHN) for specimen depths of 8 mm (in 1 mm increments).

Methods

The degree of conversion (DC) was measured by monitoring the peak height (6164 cm−1) of specimens (11.0 ± 0.1 mm diameter, 1.0 ± 0.1 mm thickness) during light irradiation for 20 s using a quartz tungsten halogen light curing unit at 650 ± 26 mW/cm2. DC was measured up to 120 s post irradiation and repeated (n = 3) for irradiation depths up to 8 mm (in 1 mm increments). Further series (n = 20) of eight discs were prepared, stacked, light irradiated and numbered from one to eight (distance from the LCU). The specimens were stored at 37 ± 1 °C for 24 h and BFS tested with the fracture fragments used to determine the VHN for each specimen.

Results

X-tra base can be irradiated to 8 mm without a change in DC, something the SDR material cannot claim. However, the DC results confirm both bulk-fill flowable RBC bases have a depth of cure in excess of 4 mm. One-way ANOVAs of BFS and VHN data showed significant differences between irradiation depths for x-tra base and SDR with increasing irradiation depth (4 mm) resulting in significant reductions in mean BFS and VHN.

Significance

The claims that the bulk-fill flowable RBC bases have a depth of cure in excess of 4 mm can be confirmed but the differing chemistry of the resin formulations and filler characteristics contribute to significant differences in DC, BFS and VHN data between the two materials tested.

Introduction

The introduction of chemically cured resin-based composites (RBCs) composed of bisphenol-A and glycidyl methacrylate (BisGMA) monomeric resin with a quartz or aluminosilicate glass filler particulate [1], paved the way for the beginnings of esthetic restorative dentistry. Similar to dental amalgams, the first chemically cured RBCs were placed in bulk without etching the tooth surfaces with phosphoric acid [2] but at that time the in vivo clinical performance was discouraging when compared with dental amalgam [3]. Chemically cured RBCs were therefore not advocated for use in large posterior restorations until the development of light irradiation technology [4], systems to aid adhesion to sound tooth structure [5] and appropriate filler morphology to effectively withstand masticatory load patterns. In 1978, Dart et al. [4] patented a visible-light irradiated RBC which when used in conjunction with ‘total etch’ adhesives developed in the 1980s [5] truly transformed esthetic restorative dentistry. More than 30 years on, most RBC monomeric formulations contain BisGMA and/or other dimethacrylates although novel technologies such as higher molecular weight resins and hydrogenated dimer acids and novel (non-dimethacrylate) epoxy chemistries have been commercialized [6]. Bowen's original quartz or aluminosilicate glass fillers [1] have been superseded by a variety of ceramic filler particle compositions often with differing filler densities, filler volume fractions, mean filler particle sizes and a general reduction in average filler particle size [7].

Notwithstanding the technical advances in RBC technologies since the patenting of chemically cured RBCs by Bowen in 1958 [8], the major disadvantages of the state-of-the-art RBCs include an insufficient depth of cure [9] and the generation of polymerization shrinkage stress [10], [11] on light irradiation. This is evident, for example, in the restoration of large Class II restorations with conventional RBC materials where as a result of the insufficient depth of cure, an incremental RBC restoration technique is required [12]. This requires either triangular-shaped [13], [14] or horizontal increments [12], [15] of maximum 2 mm thickness for the mesial approximal box, three for the distal approximal box and two for the occlusal cavity. Depending on the RBC formulation, the light irradiation time can vary from 20 to 40 s per increment, which is time consuming for the operator and an inconvenience to the patient [16]. In addition to the increased patient treatment times, there is also an associated increased risk of air entrapment or moisture contamination between the individual RBC increments [17].

So-called “bulk-fill” flowable RBC bases have been recently introduced into the dental market for use beneath conventional RBC materials [18], [19]. These materials claim to promote light transmittance [20] to enable the achievement of a reported depth of cure in excess of 4 mm [21]. In the dental literature, studies investigating the clinical performance of bulk-fill flowable RBC base materials are limited [20], [21], [22], [23]. However, when bulk-fill flowable RBC base materials were placed in a single 4 mm increment, investigations on marginal quality [22], cuspal deflection [21], cuspal deflection in conjunction with microleakage [23] and adhesion to cavity-bottom dentin [20] have been reported. Roggendorf et al. [22] used a Class II fatigue loading design study to establish that the marginal adaption of SDR to enamel and dentin was not influenced by the placement of a single 4 mm bulk-fill flowable RBC base compared with two separate 2 mm increments of a conventional dimethacrylate RBC. Moorthy et al. [23] employed a twin channel deflection measuring gauge to assess the cuspal deflection of standardized large Class II cavities incrementally filled with a conventional dimethacrylate RBC or with bulk-fill flowable RBC bases. The authors established the polymerization stress generated on light irradiation of the bulk-fill flowable RBC bases was significantly lower than a conventional dimethacrylate RBC [23], confirming the results of Ilie and Hickel [24]. Additionally, the cervical microleakage scores of Moorthy et al. [23] for the teeth restored with the bulk-fill flowable RBC bases (SDR and x-tra base) confirmed the marginal integrity results reported by Roggendorf et al. [22]. Van Ende et al. [20] used microtensile bond strength testing to show that a high bond strength value to the cavity-bottom dentin was maintained when SDR was light irradiated to a cavity depth of 4 mm. While these studies [20], [21], [22], [23] collectively advocate the clinical use of bulk-fill flowable RBC bases, the published reports on the mechanical properties of bulk-fill flowable RBC bases [17], [24], [25], [26], [27], [28] which are often purported to being maintained at a depth of 4 mm [27] are more difficult to confirm. Therefore, while these current manuscripts do add to the existing knowledge base on bulk-fill flowable RBC bases [17], [24], [25], [26], [27], [28], rarely do the findings reported have any clinical significance in terms of quantifying their ‘true’ depth of cure and as a result their potential clinical efficacy.

The aim of the current study was to assess the physico-mechanical properties of two bulk-fill flowable RBC base materials through depth. The null hypothesis examined in the study was that the physico-mechanical properties of two bulk-fill flowable RBC base materials would be reduced with increased distance from the light irradiation source.

Section snippets

Materials

The bulk-fill flowable RBC base materials used in the current study were x-tra base (Shade U, Lot 1204418; Voco GmbH, Cuxhaven, Germany) and SDR (Shade U, Lot 1203001032; Dentsply DeTrey GmbH, Konstanz, Germany).

Degree of conversion (DC)

Degree of conversion (DC) was measured by Fourier transform infrared spectroscopy (FTIRS; Nicolet 6700; Thermo Nicolet Instruments Co., Madison, WN, USA) using attenuated total reflection (ATR) and measuring the change in height of the peak at 1635 cm−1 corresponding with the aliphatic

Results

The change in DC, BFS and VHN data for x-tra base and SDR with irradiation depths up to 8 mm (in 1 mm increments) are shown in Fig. 2a–c, respectively. The Shapiro–Wilk tests confirmed all BFS and VHN irradiation depth groups investigated were normally distributed (p > 0.063).

The mean DC and associated standard deviation of x-tra base varied from a maximum of 48 (1)% at irradiation depths of 1, 3, 4 and 5 mm to a minimum of 43 (4)% at irradiation depths of 7 and 8 mm. The one-way ANOVA of the DC data

Discussion

Clinical studies advocate the use of bulk-fill flowable RBC bases [20], [21], [22], [23] but the published reports on their mechanical properties [17], [24], [25], [26], [27], [28] are more difficult to assess. El-Safty et al. [25], [26] assessed the creep deformation of SDR and x-tra base to be comparable with flowable and conventional dimethacrylate RBC formulations. The nanoindentation creep specimens used (15 mm diameter, 2 mm thickness) were ‘irradiated from top and bottom surfaces in

Conclusion

The bold claims that the bulk-fill flowable RBC bases have a reported depth of cure in excess of 4 mm can be confirmed from the DC, BFS and VHN analyses. It is interesting to note that the differing chemistry of the monomeric resin formulations and filler characteristics (type volume fraction, density and particle size and distribution) contribute to significant differences in DC, BFS and VHN data between the two bulk-fill flowable RBC bases tested.

Acknowledgements

The authors would acknowledge receipt of the bulk-fill flowable RBC base materials SDR and x-tra base from Rebecca Evans, Dentsply Ltd., Surry, United Kingdom and Dr. Martin Danebrock, Voco, Cuxhaven, Germany.

References (45)

  • S. Flury et al.

    Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials

    Dental Materials

    (2012)
  • A. Van Ende et al.

    Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity bottom dentin

    Dental Materials

    (2013)
  • C.E. Campodonico et al.

    Cuspal deflection and depth of cure in resin-based composite restorations filled by using bulk, incremental and transtooth-illumination techniques

    Journal of the American Dental Association

    (2011)
  • M.J. Roggendorf et al.

    Marginal quality of flowable 4-mm base vs conventionally layered resin composite

    Journal of Dentistry

    (2011)
  • A. Moorthy et al.

    Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials

    Journal of Dentistry

    (2012)
  • N. Ilie et al.

    Investigations on a methacrylate-based flowable composite based on SDR™ technology

    Dental Materials

    (2011)
  • S. El-Safty et al.

    Nanoidentation creep versus bulk compressive creep of dental resin-composites

    Dental Materials

    (2012)
  • S. El-Safty et al.

    Creep deformation of restorative resin-composites intended for bulk-fill placement

    Dental Materials

    (2012)
  • S. El-Safty et al.

    Nanomechanical properties of dental resin-composites

    Dental Materials

    (2012)
  • W.M. Palin et al.

    Monomer conversion versus flexure strength of a novel dental composite

    Journal of Dentistry

    (2003)
  • W.M. Johnston et al.

    A mathematical model for post-irradiation hardening of photoactivated composite resins

    Dental Materials

    (1985)
  • L. Musanje et al.

    Polymerization of resin composite restorative materials: exposure reciprocity

    Dental Materials

    (2003)
  • Cited by (91)

    View all citing articles on Scopus
    View full text