Elsevier

Biomaterials

Volume 26, Issue 6, February 2005, Pages 661-670
Biomaterials

Characterization of biodegradable drug delivery vehicles with the adhesive properties of leukocytes II: effect of degradation on targeting activity

https://doi.org/10.1016/j.biomaterials.2004.03.003Get rights and content

Abstract

The site-specific expression of selectins (P- and E-selectin) on endothelial cells of blood vessels during inflammation provides an opportunity for the targeted delivery of anti-inflammatory drugs to sites of chronic inflammation. It is well documented that the selectins mediate the initial interaction (rolling) of leukocytes in an inflamed vessel by binding to carbohydrate-presenting counter-receptors displayed on leukocytes. Previous work in our laboratory has shown that artificial capsules with the adhesive properties of leukocytes can be made by attaching leukocyte adhesive ligands to polymer microspheres (Biomaterials 23(10) (2002) 2167). Specifically, we showed that drug-loaded poly (lactic-co-glycolic-acid) (PLGA) microspheres coated with biotinylated-Sialyl LewisX (sLeX), a carbohydrate that serves as a ligand to selectins, mimic the adhesive behavior of leukocytes on selectins in flow chambers, displaying slow rolling under flow, suggesting that these drug-loaded particles can potentially target inflammatory sites in vivo. Since the effectiveness of this delivery system might depend on the degradation of polymer microspheres as well as the degradation of sLeX molecules, we measured the effect of polymer and ligand degradation on the adhesiveness of microspheres over time. We show that degrading sLeX microspheres maintain the ability to recognize selectin surfaces under flow for at least 2 weeks and that the ability to sustain recognition depends upon the extent at which microspheres are loaded. We also show that microsphere rolling velocity increases as microsphere degrade and that this increase is due to a combination of increase in average microsphere size and loss of sLeX molecules on microsphere surface—a result of microsphere degradation confirmed by flow cytometry. Control experiments show that microsphere, not sLeX, degradation limits the lifetime of our targeted delivery system; therefore, factors affecting degradation such as type of polymer, type of drug, extent of drug loading and microsphere size, provide an opportunity for engineering the time-scale of activity for the delivery system.

Introduction

Targeting therapeutics to specific sites in the body is attractive because it potentially allows for the administration of potent therapeutic agents to diseased cells/tissues without affecting normal ones, thereby enhancing drug efficacy without generating deleterious side effects. Several avenues exist for drug targeting depending on the intended site of delivery and the targeted therapeutic. Some of the avenues that have been exploited include targeting via monoclonal drug-antibodies hybrids, immuno-liposomes, cellular carriers and antibody/receptor-linked biodegradable particles [1], [2], [3]. Drug carriers such as liposomes and polymer microspheres are often preferred over molecular conjugates and protein carriers because these carriers protect drug from degradation or digestion. However, biodegradable polymer carriers have advantages over lipid vesicles, such as stability and sustained release, and are increasingly finding application in several human diseases because they offer flexibility in design, allowing for high control over drug loading and the dynamics of release [4].

Much has been written regarding the preparation and use of biodegradable polymer microspheres, such as poly(lactic-co-glycolic acid) (PLGA), for targeted delivery of therapeutics in several diseases [3], [5], [6], [7]. However, most work has focused on the fabrication and/or characterization of the physical properties of drug-loaded particle. Some work has focused on the conjugation of targeting ligands to the surface of biodegradable carriers and tests of functionality of targeted system. To our knowledge, no work exists describing the lifetime of a targeting system. We expect that the effectiveness of targeted, biodegradable delivery system over time will depend on the rate of degradation, since the targeting (adhesive) ligand is often linked to the biodegradable polymer chain.

We recently described a novel approach for targeting therapeutic agent to the vascular wall in inflammatory diseases using biodegradable polymer microspheres made from PLGA, to which we attached selectin ligand, sLeX [8]. Ligand attachment to microspheres was achieved by covalently linking the protein NeutraAvidin, which strongly binds biotin, to the carboxylic acid end-group on the terminal lactic acid chain thereby allowing the attachment of biotinylated sLeX molecules. We showed that these sLeX-coated carriers transiently adhere to (roll on) P-selectin surfaces, similar to how leukocytes roll on P-selectin under flow, and that the adhesion can be tuned by changing the density of sLeX on the microsphere surface, thus setting the rolling velocity in blood vessels [8]. Targeted delivery to the endothelium in inflammatory diseases via the selectins (E- and P-selectin) is attractive because of their localized and carefully regulated expression patterns in response to inflammatory mediators, such as histamine and tumor necrosis factor (TNF) [9], [10].

Since the PLGA drug carriers are degradable, we expect that the lifetime of selectin-recognition of targeted sLeX-particles will depend on the rate and mechanism of degradation of the polymer PLGA. Whether the bulk of adhesion is lost early during degradation depends on whether the surface or the bulk of the particle erodes first. Langer's lab has shown that PLGA particles degrade via bulk erosion [9], [11], suggesting our particles will be active for an extended period of time. Here, we present the results obtained from in vitro assays designed to characterize the possible effect of polymer and ligand degradation on the selectin-recognition ability of this targeted delivery system. We show that degrading sLeX microspheres maintain the ability to recognize selectin surfaces (roll) under flow for up to 3 weeks in solution and that the time-scale of recognition is directly related to the time-scale of degradation. Overall, understanding the relationship between the properties of degradable polymer carriers that prescribe the rate of degradation and the lifetime of targeting will help develop sophisticated targeted, degradable drug carriers with tunable life-times and activities.

Section snippets

Materials

50,000 MW, acid-end, 50/50 PLGA was purchased from Alkermes Inc. (Cincinnati, OH). Methylene chloride, NeutraAvidin, diclofenac sodium salt (DSS), bovine serum albumin (BSA), polyvinyl alcohol (MW∼70,000), Dulbecco's phosphate buffered saline (DPBS), and Tris base were purchased from Sigma (St. Louis, MO). Biotinylated, multivalent sialyl LewisX (sLeX) carbohydrate was purchased from Glycotech (Rockville, MD). Soluble P-selectin (sP) was a generous gift from Drs. Raymond T. Camphausen and Gray

Degrading microsphere continue to recognize selectin surfaces in flow

Unloaded, R6G- and DSS-loaded, sialyl-LeX-coated PLGA microspheres were allowed to degrade in phosphate buffer saline (PBS+) over time at 37°C. At various times, 4×105 microspheres were removed from solution and allowed to interact with selectin surfaces in a parallel plate flow chamber. Flow chamber experiments were conducted over a period of 3 weeks, and microsphere interactions with selectin surfaces were quantified by measuring microsphere “rolling” fluxes and velocities. Fig. 1A shows a

Discussion

We previously described a targeted drug delivery system that has potential application in treating several vascular human diseases [8]. This system was made by conjugating selectin adhesive ligand, sLeX, to the surface of biodegradable, drug-loaded, Poly(lactic-co-glycolic acid) (PLGA) polymer microspheres via avidin–biotin bonding, where avidin was covalently linked to the acid end-group on polymer chains using carbodiimide chemistry. We showed that these carbohydrate coated microspheres mimic

Conclusions

In summary, we have studied the lifetime of selectin recognition of a targeted, biodegradable drug delivery vehicle [8] designed to mimic a leukocyte. We showed that the rate of microsphere degradation is controlled by rate of drug loading, type of encapsulated drug and method of microsphere fabrication, and that degradation controls the selectin-mediated targeting of the system. Therefore, tuning degradation through composition and molecular weight of polymer used will dictate the lifetime of

Acknowledgements

We gratefully acknowledge support from NIH GM59100. We thank Mr. Eric Johnston at the University of Pennsylvania for his technical support.

References (27)

  • V.R Patil et al.

    Particle diameter influences adhesion under flow

    Biophys J

    (2001)
  • G Molema

    Drug Targeting: basic concepts and novel advances

  • D.D Spragg et al.

    Immunotargeting of liposomes to activated vascular endothelial cellsa strategy for site-selective delivery in the cardiovascular system

    Proc Natl Acad Sci USA

    (1997)
  • Cited by (55)

    • History, introduction, and properties of PLGA as a drug delivery carrier

      2023, Poly(lactic-co-glycolic acid) (PLGA) Nanoparticles for Drug Delivery
    View all citing articles on Scopus