Abstract

To evaluate the force and torque acting on leukocytes attached to the vessel wall, we numerically study the flow field around the leukocytes by using rigid spherical particles adhered to the wall of a circular cylindrical tube as a model of adherent leukocytes. The adherent particles are assumed to be placed regularly in the flow direction with equal spacings, in one row or two rows. The flow field of the suspending fluid is analyzed by a finite element method applied to the Stokes equations, and the drag force and torque acting on each particle, as well as the apparent viscosity, are evaluated as a function of the particle to tube diameter ratio and the particle arrangements. For two-row arrangements of adhered particles where neighboring particles are placed alternately on opposite sides of the vessel, the drag and the torque exerted on each particle are higher than those for single-row arrangements, for constant particle to tube diameter ratio and axial spacing between neighboring particles. This is enhanced for Larger particles and smaller axial spacings. The apparent viscosity of the flow through vessels with adhered particles is found to be significantly higher than that without adhered particles or when the particles are freely floating through the vessels.

References (21)

There are more references available in the full text version of this article.

Cited by (10)

  • Micro-PTV measurement of the fluid shear stress acting on adherent leukocytes in vivo

    2009, Biophysical Journal
    Citation Excerpt :

    For each microsphere position within 2 μm of the leukocyte surface, we calculated the local shear rate acting on the adherent leukocyte, γs, and normalized it to the wall shear rate, γw. Based on earlier CFD work (48), an angle, θ, was defined between the leukocyte peeling edge, leukocyte center and microsphere position (Fig. 5A, inset). Grouping shear rate measurements into similar stress regions, as shown in Fig. 5A (inset), we repeated the linear fit analysis to determine shear rate and ESL thickness.

  • Blood flow and permeability in microvessels

    2005, Fluid Dynamics Research
  • The fluid mechanics of cancer and its therapy

    2013, Annual Review of Fluid Mechanics
  • Shear field around adherent leukocytes as measured by micro-PTV

    2007, Conference Record - Asilomar Conference on Signals, Systems and Computers
View all citing articles on Scopus