Commentary

The authors of two papers that have recently been published online in this journal [1, 2] compared data on an Indian population with corresponding data from 41 other countries (denoted the rest of the world, ROW), based on the results of an Injection Technique Questionnaire (ITQ) survey performed throughout India and involving 1011 patients, which provided information on overall injecting practices, injection complications, and health care professional education in their country. While diligently describing possible differences between the insulin delivery technique applied in India and that used in the rest of the world, they were able to shed light on some issues that may be easily extended to a global context.

Their overall results may be summarized as follows:

  • Mean HbA1c was 8.6, and the total daily dose (TDD) of insulin was lower than in the ROW (probably due to the fact that BMI values were 1.5–3 units lower as well, which increased the risk of intramuscular (IM) injections)

  • Needle reuse and the number of times that needles were used were much higher, and thighs (associated with riskier IM injections) were chosen for injections more often in India than in the ROW

  • More than a quarter of Indian insulin users described lesions consistent with lipohypertrophy (LH) at their injection sites; approximately 1 in 5 users were found to have LH by the examining nurse, and about half of them had suffered painful injections

  • Despite a specialized educational approach, many of the patients reported that they had not been trained well enough and had seldom had their sites checked during periodic visits

Therefore, importantly, those two papers clearly show that appropriate injection technique is a major issue in the real world, which is why we were driven to write the following extended commentary that simultaneously attempts to provide the readers of this journal with an updated overview of this topic.

Compliance with Ethics Guidelines

This article is based on previously published investigations and does not involve any new studies of human or animal subjects performed by the authors.

Unmet Needs of Insulin Therapy

Even though some 90 years have passed since insulin was first commercialized, a fairly large number of patients are still not using an appropriate injection technique. Moreover, although advances in technology have made new syringes, pens, and increasingly short, thin, and sharp needles available, insulin treatment has not yielded the expected results—many issues have not yet been resolved, and there are still too many unmet needs. As a matter of fact, only half of all insulin-treated patients reach their therapeutic targets worldwide [3], so it is crucial that insulin is routinely injected into healthy subcutaneous tissue.

How are the Recommendations Applied?

The factors involved in nonoptimal and quite often unpredictable insulin absorption have been identified during the last 10 years or so [4,5,6]: (1) the use of overlong needles; (2) frequent needle reutilization; (3) failure to systematically rotate injection sites; (4) missed skinfold pinching/45° angle needle injection in thin people; (5) failure to systematically inspect/palpate LH skin nodules before injections; (6) patient underestimation of guidelines on correct insulin injection; (7) a lack of preliminary structured education concerning the best injection modalities; (8) missed regular patient refresher courses; and (9) a lack of regular nurse examinations at which skin lesions and/or inappropriate injection modalities are identified. Indeed, these bad habits are widespread, and have been addressed by several scientific publications [6], including regularly issued guidelines and expert recommendations suggesting practical solutions for correcting behavior. However, LH is still frequent and is associated with clinical consequences, including poor metabolic control [7, 8], severe hypoglycemic episodes, and high health/social costs [9].

In addition, injections are often painful, thus reducing compliance to treatment. Therefore, to try to prevent pain and simplify the injection technique, shorter (4- and 5-mm) needles have been developed and commercialized and careful training is recommended. Nevertheless, patients and nurses still often use 8-mm needles which exceed the thickness of the skin and subcutaneous fat and thus penetrate into the muscle. This is bound to cause poor glycemic control [7, 8], as discussed in greater detail in the next paragraph.

Body Structure and Skin and Subcutaneous Tissue Anatomy

Over the last few decades, it has become increasingly apparent that body structure, funding, and the availability of updated devices or next-generation insulins vary markedly among International Diabetes Federation (IDF) member regions.

As far as skin and subcutaneous tissue (SCT) structure is concerned, several studies have highlighted that the average BMI is lower in adult or infant Asians than in the ROW [1, 2, 10,11,12,13,14] (especially in Europeans [15,16,17,18,19]), as well as the existence of a positive correlation between SCT thickness and BMI. Because the skin and subcutaneous adipose layer are relatively thin in subjects with a low BMI, they are at a high risk for accidental intramuscular injections [10,11,12,13,14]. Considering the multiethnicity of Western societies, it is important to take this issue into account in Western populations.

In an ultrasound evaluation of an adult Chinese population [11], skin thickness showed only a minimal dependence on body site and on various demographic characteristics (including age, gender, type of diabetes, and BMI), whereas SCT appeared to be far more variable: its thickness was greater in women, at the abdominal level, and in patients with a high BMI. Studies of skin and SCT thicknesses in other Asian populations, such as Filipinos [12], Koreans [13], and Indians [14], yielded comparable results to those obtained for the Chinese population, whereas non-Asian populations had considerably higher BMIs in a major ultrasound-based study [16, 17].

Lower BMI values may also have contributed to the popularity of shorter insulin needles, as Indian patients become aware of the risks of IM injections with longer needles when the BMI is low.

Recent studies of a large population of adults with diabetes found that the skin thickness at the insulin injection site differed minimally with patient characteristics such as the BMI (i.e., obese patients had similar skin thicknesses to normal and thin patients) [13, 20]. However, the same study showed that fat thickness (SC space) varied widely from one individual to another based on gender, BMI, and injection area. It highlighted the risk of IM injections, and showed that 4-mm needles presented the lowest risk of such injections. A study recently published in India confirmed those findings [16].

Are Patients Provided with Structured Education or Simple Information?

The other important issue that is raised by the papers from Indian authors [1, 2] is that real-life injection habits do not match the guidelines published in many countries, especially the latest recommendations published by the panel of experts attending the 2015 FITTER Congress in Rome [20]. Economic factors work against clinically appropriate solutions, as repeated reuse of the same needle is a widespread habit in Indian patients. That said, this practice appears to be highly prevalent worldwide due to not only financial constraints but also a dangerous mix of ignorance, opportunism, and laziness indulged in by both patients and operators. In everyday practice, structured education appears to be hardly (if ever) performed, as reported by a large number of both Indian [1, 2, 14] and Italian [16,17,18] patients. Sadly, there are also no guidelines suggesting how related knowledge should be reinforced by appropriate educational follow-up sessions that also give health care providers a chance to verify the injection habits of individual patients. Moreover, although professional educators are available for this purpose in several countries, in other countries doctors and nurses acting as self-learners often attempt to improvise the role of expert educators; after providing their patients with superficial information, they do not plan any periodic refresher or quality control sessions. The result is a widespread lipodystrophic phenomenon [7] and a high rate of seemingly inexplicable hypoglycemia and high glycemic variability that are closely related to poor injection techniques, which could eventually be prevented or reversed by experienced structured educational activities [7, 19, 21].

Conclusions

The variable yet high rate of localized insulin treatment complications reveals that proper injection technique recommendations are often either unknown or almost completely disregarded worldwide [7]. These unmet needs lead to high glycemic variability with frequent apparently unexplainable hypoglycemic episodes, which in turn trigger a series of negative consequences for glycemic control, quality of life, and health and social costs [22]. Recently published recommendations on this topic [20] are comprehensive and practical but have little chance of being implemented by many insulin-treated patients. Health care providers must realize that better and better insulins, injection systems, or advanced technologies are useless in the absence of effective structured educational programs which address how, what, and where the insulin shot should be given. Data provided by Indian colleagues that compare Indian patients to the rest of the world [1, 2] suggest that body structure varies significantly with ethnicity. This issue should therefore also be taken into account when personalizing treatment in terms of needle length in everyday clinical practice.