Abstract
The loss or absence of an auricle may result from trauma, disease or congenital anomalies and causes a considerable aesthetic problem. If the deformity involves the external auditory canal, it can affect hearing. This case report describes the surgical and prosthetic treatment of two patients with partial defects of their right external ears from different causes. Implant-retained auricular prostheses fabricated from heat-temperature-vulcanised silicone were used in both the cases; they were designed to be harmonious with the remaining tissues. The patients experienced improved retention, aesthetics, hearing and quality of life with these prostheses. During the approximately 3 year follow-up, both the prostheses were re-fabricated once; however, problems related to implant stability and peri-implant tissue health were not encountered.
References
Henry PJ (1992) Maxillofacial prosthetic considerations. In: Worthington P, Branemark PI (eds) Advanced osseointegration surgery: applications in the maxillofacial region, 1st edn. Quintessence, Chicago, pp 313–326
Ciorba A, Martini A (2005) Tissue engineering and cartilage regeneration for auricular reconstruction. Int J Pediatr Otorhinolaryngol 70:1507–1515. doi:10.1016/j.ijporl.2006.03.013
Cognetti DM, Weber RS, Lai SY (2008) Head and neck cancer: an evolving treatment paradigm. Cancer 113:1911–1932. doi:10.1002/cncr.23654
Hooper SM, Westcott T, Evans PL, Bocca AP et al (2005) Implant-supported facial prostheses provided by a maxillofacial unit in a UK regional hospital: longevity and patient opinions. J Prosthodont 14:32–38. doi:10.1111/j.1532-849X.2005.00004.x
Brent B (1981) A personal approach to total auricular construction: case study. Clin Plast Surg 8:211–221
Holgers KM, Tjellstrom A, Bjursten LM, Erlandsson BE (1987) Soft tissue reactions around percutaneous implants: a clinical study on skin-penetrating titanium implants used for bone-anchored auricular prostheses. Int J Oral Maxillofac Implants 2:35–39
Tjellström A, Yountchev E, Lindström J, Branemark PI (1985) Five years’ experience with bone-anchored auricular prostheses. Otolaryngol Head Neck Surg 93:366–372
Nishimura RD, Roumanas E, Sugai T, Moy PK (1995) Auricular prostheses and osseointegrated implants: UCLA experience. J Prosthet Dent 73:553–558. doi:10.1016/S0022-3913(05)80115-5
Wazen JJ, Wright R, Hatfield RB, Asher ES (1999) Auricular rehabilitation with bone-anchored titanium implants. Laryngoscope 109:523–527. doi:10.1097/00005537-199904000-00001
Tjellstrom A (1990) Osseointegrated implants for replacement of absent or defective ears. Clin Plast Surg 17:355–366
Wang RR, Andres CJ (1999) Hemifacial microsomia and treatment options for auricular replacement: a review of the literature. J Prosthet Dent 82:197–204. doi:10.1016/S0022-3913(99)70156-3
Wright RF, Wazen JJ, Asher ES, Evans JH (1999) Multidisciplinary treatment for an implant retained auricular prosthesis rehabilitation. N Y State Dent J 65:26–31
Lemon JC, Chambers MS (2002) Locking retentive attachment for an implant-retained auricular prosthesis. J Prosthet Dent 87:336–338. doi:10.1067/mpr.2002.122016
Raghoebar GM, Van Oort RP, Roodenburg JL, Reintsema H et al (1994) Fixation of auricular prostheses by osseointegrated implants. J Invest Surg 7:283–290. doi:10.3109/08941939409051146
Ciocca L, Mingucci R, Gassino G, Scotti R (2007) CAD/CAM ear model and virtual construction of the mold. J Prosthet Dent 98:339–343. doi:10.1016/S0022-3913(07)60116-4
Aydin C, Karakoca S, Yilmaz H, Yilmaz C (2008) Implant-retained auricular prosthesis: an assessment of implant success and prosthetic complications. Int J Prosthodont 21:241–244
Alberktsson T (1998) Surgical and prosthetic considerations. In: Branemark PI, Tolman DE (eds) Osseointegration in craniofacial reconstruction, 1st edn. Illinosis, Quintessence, pp 213–223
McKinstry RE (1995) Fundamentals of Facial Prosthetics. ABI Professional Publications, Arlington, pp 25–29
Cheng AC, Morrison D, Cho RS, Archibald D (1998) Vacuum-formed matrix as a guide for the fabrication of craniofacial implant tissue bar-retained auricular prostheses. J Prosthet Dent 79:711–714. doi:10.1016/S0022-3913(98)70081-2
McCartney JW (1991) Osseointegrated implant-supported and magnetically retained ear prosthesis: a clinical report. J Prosthet Dent 66:6–9. doi:10.1016/0022-3913(91)90342-T
Andres CJ, Haug SP (2000) Facial prosthesis fabrication: technical aspects. In: Taylor TD (ed) Clinical maxillofacial prosthetics, 1st edn. Quintessence, Chicago, pp 237–240
Nusinov NS, Gay WD (1980) A method for obtaining the reverse image of an ear. J Prosthet Dent 44:68–71. doi:10.1016/0022-3913(80)90049-9
Lemon JC, Chambers MS, Wesley PJ, Martin JW (1996) Technique for fabricating a mirror-image prosthetic ear. J Prosthet Dent 75:292–293. doi:10.1016/S0022-3913(96)90487-4
Kiat-amnuay S, Johnston DA, Powers JM, Jacob RF (2005) Color stability of dry earth pigmented maxillofacial silicone A-2186 subjected to microwave energy exposure. J Prosthodont 14:91–96. doi:10.1111/j.1532-849X.2005.00017.x
Jani RM, Schaaf NG (1978) An evaluation of facial prostheses. J Prosthet Dent 39:546–550. doi:10.1016/S0022-3913(78)80191-7
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Subaşı, M.G., Alnıaçık, G., Kalaycı, A. et al. Prosthetic Rehabilitation of Partial Ear Defect: 2 Case Reports. J Indian Prosthodont Soc 14 (Suppl 1), 196–201 (2014). https://doi.org/10.1007/s13191-012-0251-5