Skip to main content

Advertisement

Log in

Prosthetic Rehabilitation of Partial Ear Defect: 2 Case Reports

  • Clinical Report
  • Published:
The Journal of Indian Prosthodontic Society

Abstract

The loss or absence of an auricle may result from trauma, disease or congenital anomalies and causes a considerable aesthetic problem. If the deformity involves the external auditory canal, it can affect hearing. This case report describes the surgical and prosthetic treatment of two patients with partial defects of their right external ears from different causes. Implant-retained auricular prostheses fabricated from heat-temperature-vulcanised silicone were used in both the cases; they were designed to be harmonious with the remaining tissues. The patients experienced improved retention, aesthetics, hearing and quality of life with these prostheses. During the approximately 3 year follow-up, both the prostheses were re-fabricated once; however, problems related to implant stability and peri-implant tissue health were not encountered.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

References

  1. Henry PJ (1992) Maxillofacial prosthetic considerations. In: Worthington P, Branemark PI (eds) Advanced osseointegration surgery: applications in the maxillofacial region, 1st edn. Quintessence, Chicago, pp 313–326

    Google Scholar 

  2. Ciorba A, Martini A (2005) Tissue engineering and cartilage regeneration for auricular reconstruction. Int J Pediatr Otorhinolaryngol 70:1507–1515. doi:10.1016/j.ijporl.2006.03.013

    Article  Google Scholar 

  3. Cognetti DM, Weber RS, Lai SY (2008) Head and neck cancer: an evolving treatment paradigm. Cancer 113:1911–1932. doi:10.1002/cncr.23654

    Article  PubMed Central  PubMed  Google Scholar 

  4. Hooper SM, Westcott T, Evans PL, Bocca AP et al (2005) Implant-supported facial prostheses provided by a maxillofacial unit in a UK regional hospital: longevity and patient opinions. J Prosthodont 14:32–38. doi:10.1111/j.1532-849X.2005.00004.x

    Article  PubMed  Google Scholar 

  5. Brent B (1981) A personal approach to total auricular construction: case study. Clin Plast Surg 8:211–221

    PubMed  Google Scholar 

  6. Holgers KM, Tjellstrom A, Bjursten LM, Erlandsson BE (1987) Soft tissue reactions around percutaneous implants: a clinical study on skin-penetrating titanium implants used for bone-anchored auricular prostheses. Int J Oral Maxillofac Implants 2:35–39

    PubMed  Google Scholar 

  7. Tjellström A, Yountchev E, Lindström J, Branemark PI (1985) Five years’ experience with bone-anchored auricular prostheses. Otolaryngol Head Neck Surg 93:366–372

    PubMed  Google Scholar 

  8. Nishimura RD, Roumanas E, Sugai T, Moy PK (1995) Auricular prostheses and osseointegrated implants: UCLA experience. J Prosthet Dent 73:553–558. doi:10.1016/S0022-3913(05)80115-5

    Article  PubMed  Google Scholar 

  9. Wazen JJ, Wright R, Hatfield RB, Asher ES (1999) Auricular rehabilitation with bone-anchored titanium implants. Laryngoscope 109:523–527. doi:10.1097/00005537-199904000-00001

    Article  PubMed  Google Scholar 

  10. Tjellstrom A (1990) Osseointegrated implants for replacement of absent or defective ears. Clin Plast Surg 17:355–366

    PubMed  Google Scholar 

  11. Wang RR, Andres CJ (1999) Hemifacial microsomia and treatment options for auricular replacement: a review of the literature. J Prosthet Dent 82:197–204. doi:10.1016/S0022-3913(99)70156-3

    Article  PubMed  Google Scholar 

  12. Wright RF, Wazen JJ, Asher ES, Evans JH (1999) Multidisciplinary treatment for an implant retained auricular prosthesis rehabilitation. N Y State Dent J 65:26–31

    PubMed  Google Scholar 

  13. Lemon JC, Chambers MS (2002) Locking retentive attachment for an implant-retained auricular prosthesis. J Prosthet Dent 87:336–338. doi:10.1067/mpr.2002.122016

    Article  PubMed  Google Scholar 

  14. Raghoebar GM, Van Oort RP, Roodenburg JL, Reintsema H et al (1994) Fixation of auricular prostheses by osseointegrated implants. J Invest Surg 7:283–290. doi:10.3109/08941939409051146

    Article  PubMed  Google Scholar 

  15. Ciocca L, Mingucci R, Gassino G, Scotti R (2007) CAD/CAM ear model and virtual construction of the mold. J Prosthet Dent 98:339–343. doi:10.1016/S0022-3913(07)60116-4

    Article  PubMed  Google Scholar 

  16. Aydin C, Karakoca S, Yilmaz H, Yilmaz C (2008) Implant-retained auricular prosthesis: an assessment of implant success and prosthetic complications. Int J Prosthodont 21:241–244

    PubMed  Google Scholar 

  17. Alberktsson T (1998) Surgical and prosthetic considerations. In: Branemark PI, Tolman DE (eds) Osseointegration in craniofacial reconstruction, 1st edn. Illinosis, Quintessence, pp 213–223

    Google Scholar 

  18. McKinstry RE (1995) Fundamentals of Facial Prosthetics. ABI Professional Publications, Arlington, pp 25–29

    Google Scholar 

  19. Cheng AC, Morrison D, Cho RS, Archibald D (1998) Vacuum-formed matrix as a guide for the fabrication of craniofacial implant tissue bar-retained auricular prostheses. J Prosthet Dent 79:711–714. doi:10.1016/S0022-3913(98)70081-2

    Article  PubMed  Google Scholar 

  20. McCartney JW (1991) Osseointegrated implant-supported and magnetically retained ear prosthesis: a clinical report. J Prosthet Dent 66:6–9. doi:10.1016/0022-3913(91)90342-T

    Article  PubMed  Google Scholar 

  21. Andres CJ, Haug SP (2000) Facial prosthesis fabrication: technical aspects. In: Taylor TD (ed) Clinical maxillofacial prosthetics, 1st edn. Quintessence, Chicago, pp 237–240

    Google Scholar 

  22. Nusinov NS, Gay WD (1980) A method for obtaining the reverse image of an ear. J Prosthet Dent 44:68–71. doi:10.1016/0022-3913(80)90049-9

    Article  PubMed  Google Scholar 

  23. Lemon JC, Chambers MS, Wesley PJ, Martin JW (1996) Technique for fabricating a mirror-image prosthetic ear. J Prosthet Dent 75:292–293. doi:10.1016/S0022-3913(96)90487-4

    Article  PubMed  Google Scholar 

  24. Kiat-amnuay S, Johnston DA, Powers JM, Jacob RF (2005) Color stability of dry earth pigmented maxillofacial silicone A-2186 subjected to microwave energy exposure. J Prosthodont 14:91–96. doi:10.1111/j.1532-849X.2005.00017.x

    Article  PubMed  Google Scholar 

  25. Jani RM, Schaaf NG (1978) An evaluation of facial prostheses. J Prosthet Dent 39:546–550. doi:10.1016/S0022-3913(78)80191-7

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Meryem Gülce Subaşı.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Subaşı, M.G., Alnıaçık, G., Kalaycı, A. et al. Prosthetic Rehabilitation of Partial Ear Defect: 2 Case Reports. J Indian Prosthodont Soc 14 (Suppl 1), 196–201 (2014). https://doi.org/10.1007/s13191-012-0251-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13191-012-0251-5

Keywords

Navigation