Development and Validation of Method with Evaluation of Measurement Uncertainty for the Speciation Analysis of Chromium by Ion Chromatography

  • Original Paper
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

In the present study a simple, sensitive and accurate method has been developed for the speciation analysis of chromium(III) and chromium(VI) in aqueous solution using ion chromatography separation followed by detection through a UV detector. Chromium(III) was detected as its pyridine-2,6-dicarboxylic acid (PDCA) complex at 365 nm by pre-derivatizing it with eluent containing PDCA. Chromium(VI) was detected by post column derivatization with diphenylcarbazide at 540 nm. This paper discusses in details about the method validation and established each parameter according to the IUPAC and EURACHEM approaches. Method is validated for linearity, accuracy, precision, limit of detection and limit of quantification as per the guide lines. The evaluation of expanded uncertainty in measurement of Cr(III) and Cr(VI) was done at 95 % confidence level (k = 2) according to EURACHEM GUM guide. The method can be applied to determine Cr(III) and Cr(VI) up to 2 mg/kg and 40 µg/kg respectively with associated measurement uncertainty value of about 5 %. The major contribution of uncertainty is due to recovery. The method described in the present study is sensitive, selective and capable of quantifying trace level of Cr(VI) and Cr(III).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. M.A. Jamaluddin et al., A rapid spectrometrophotometric method for the determination of chromium in environmental samples using bis(salisaldeyde) orthophenylenediamine, Res. J. Chem. Sci., 1 (2011) 46–59.

  2. A.M. Stoyanova, Catalytic spectrophotometric determination of chromium, Turk. J. Chem., 29 (2005) 367–375.

  3. J. Threeprom et al., Simultaneous determination of Cr(IIII)-EDTA and Cr(VI) by ion interaction chromatography using a C18 column, J. Chromatogr. A., 1073 (2005) 291–295.

  4. A.H. El-Sheikh, M.M.A. Hilal and J.A. Sweileh. Bio-separation, speciation and determination of chromium in water using partially pyrolyzed olive pomace sorbent, Bioresour. Technol., 102 (2011) 5749–5756.

  5. R. Christopher et al., Speciation of chromium via laser-induced breakdown spectroscopy of ion exchange polymer membranes, J. Appl. Spectrosc., 59 (2) (2005) 252–257.

  6. R. Michalski, Ion chromatography method for determination of trace lavels of chromium(VI) in water, Pol. J. Environ. Stud., 13 (1) (2004) 73–77.

  7. M. Mohammadhosseini et al., Preconcentration, determination and speciation of chromium (III) using solid phase extraction and flame atomic absorption spectrometry, J. Chin. Chem. Soc., 53 (2006), 549–557.

  8. M.A. Hossain, M. Kumita, Y. Michigami, T.S. Islam and S. Mori, Rapid speciation analysis of Cr(VI) and Cr(III) by reversed-phase high-performance liquid chromatography with UV detection, J. Chromatogr. Sci., 43 (2) (2005) 98–103.

  9. R.E. Wolf, J.M. Morrison and M.B. Goldhaber, Simultaneous determination of Cr(III) and Cr(VI) using reversed-phased ion-pairing liquid chromatography with dynamic reaction cell inductively coupled plasma mass spectrometry, J. Anal. Atom. Spectrom., 22 (2007) 1051–1060.

  10. D. Baralkiewiez, B. Pikosz, M. Belter and M. Marcinkowska, Speciation analysis of chromium in drinking water samples by ion-pair reversed-phase HPLC–ICP-MS: validation of the analytical method and evaluation of the uncertainty budget, Accred. Qual. Assur., 18 (2013) 391–401.

  11. EURACHEM/CITAC guide on quantifying uncertainty in measurement, 2nd Edn., (2000).

  12. J. Mocak, A.M. Bond, S. Mitchell and G. Schollary, A statistical overview of standard (IUPAC and ACS) and new procedures for determining the limits of detection and quantification: application to voltametric and stripping techniques, Pure Appl. Chem., 69 (2) (1997) 297–328.

  13. IC application work AW IN6-0882-122008 (Metrohm). Chromium (III) and Chromium (VI) speciation by Ion chromatography.

Download references

Acknowledgments

The authors are thankful to the Director, CSIR-NPL for his support and permission to publish this paper. The authors are thankful to Mrs. Sunita Raina for her constant help in the analysis by IC. One of the author Ms. Swati is thankful to CSIR for the financial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Swarupa Tripathy.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Swati, Tripathy, S.S., Saxena, R.K. et al. Development and Validation of Method with Evaluation of Measurement Uncertainty for the Speciation Analysis of Chromium by Ion Chromatography. MAPAN 30, 131–137 (2015). https://doi.org/10.1007/s12647-014-0130-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-014-0130-0

Keywords

Navigation