Establishment and verification of a primary low-pressure gas flow standard at NIMT

  • Original Article
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

This paper presents the establishment and verification of a primary low-pressure gas flow standard with the capacity of 0.005 L/min to 24 L/min (at 23 °C and 101.325 kPa), newly established at National Institute of Metrology of Thailand (NIMT). This facility is a mercury-sealed piston prover consisting of three precision-machined glass cylinders. Flow measurement can be carried out manually or semi-automatically. The electronics were installed in a separate console to minimize their thermal impact on the gas temperature. Special care was taken in designing the facility to ensure sound and representative gas pressure and temperature measurement. The relative expanded uncertainty of mass flow measurement was evaluated to be less than 0.13%. To verify the measurement capability and performance of the new facility, a bilateral comparison with the piston prover at Center for Measurement Standards (CMS), Taiwan was conducted. The transfer standard used was a set of three critical flow venturis with dedicated thermometers. Eight flow rates of dry air ranging from 42 mL/min to 14.5 L/ min at 0 °C and 101.325 kPa (0.055 g/min to 18.87 g/min) were tested. Comparison results showed that the E n values for the flow measurements at NIMT with reference to CMS were all well less than unity, demonstrating good agreement between the two participants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. ISO/IEC Guide 98-3:2008, Uncertainty of Measurement — Part 3: Guide to the Expression of Uncertainty in Measurement (GUM:1995), International Organization for Standardization, Geneva, Switzerland, (2008).

    Google Scholar 

  2. J.D. Wright and G.E. Mattingly, NIST Calibration Services for Gas Flow Meters: Piston Prover and Bell Prover Gas Flow Facilities, NIST Special Publication 250-49, National Institute of Standards and Technology, (1998).

  3. J.D. Wright, A.N. Johnson and M.R. Moldover, Design and Uncertainty Analysis for a PVT Gas Flow Standard, Journal of Research of the National Institute of Standards and Technology, 108 (2003) 21–47.

    Article  Google Scholar 

  4. User’s Guide, Laser Doppler Displacement MeterTM; Laser Doppler Scale, OPTODYNE Inc., (2003).

  5. J.D. Wright, What is the “Best” Transfer Standard for Gas Flow?, the 12th International Conference on Flow Measurement (FLOMEKO), Groningen, Netherlands, (2003).

  6. J.D. Wright, B. Mikan, R. Paton, K.A. Park, S. Nakao, K. Chahine and R. Arias, CIPM Key Comparison for Low-Pressure Gas Flow: CCM.FF-K6 Final Report, WGFF, CIPM, (2007).

  7. T. Morioka and S. Nakao, Protocol for the APMP Low-Pressure Gas Flow Key Comparison (APMP.TCFF-K6), Gas Flow Standards Laboratory, NMIJ, (2006).

  8. ISO 9300:2005, Measurement of Gas Flow by Means of Critical Flow Venturi Nozzles, International Organization for Standardization, Switzerland, (2005).

    Google Scholar 

  9. J. Wright, Uncertainty of the Critical Venturi Transfer Standard Used in the K6 Gas Flow Key Comparison, the 14th International Conference on Flow Measurement (FLOMEKO), Johannesburg, South Africa, (2007).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chun-Min Su.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Su, CM., Lin, WT. & Masri, S. Establishment and verification of a primary low-pressure gas flow standard at NIMT. MAPAN 26, 173–186 (2011). https://doi.org/10.1007/s12647-011-0017-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-011-0017-2

Keywords

Navigation