Skip to main content
Log in

Optimization and Experiment of Two-Dimensional Parallel Decoupling Image Stabilization Mechanism

  • Regular Paper
  • Published:
International Journal of Precision Engineering and Manufacturing Aims and scope Submit manuscript

Abstract

In order to improve the precision positioning accuracy of image stabilization mechanism, a two-dimensional image stabilization mechanism with parallel decoupling was proposed. Firstly, according to the principle of lever-half-bridge hybrid amplification mechanism, the structure of two-dimensional image stabilization mechanism was designed, the working principle was analyzed, and natural frequency of the mechanism was calculated. Secondly, static analysis, modal analysis, and flexure hinge parameter optimization of the mechanism based on ANSYS were carried out. The simulation results show that two-dimensional image stabilization mechanism can realize the micro-displacement positioning function in the X and Y directions. The resonance phenomenon does not occur when the mechanism works. The thickness and width are the sensitive parameters of flexure hinge. Finally, the actuation performance of two-dimensional image stabilization mechanism was tested during the prototype, the relationship between the output displacement in the X and Y directions and the input voltage, frequency was tested, and the displacement coupling in the X and Y directions was tested. The experimental results show that the motion displacement of the mechanism is 103.9 × 104.8 μm, and the output displacement coupling does not exceed 7.5% of the stroke. The image stabilization mechanism can realize large stroke and precision positioning functions, and is feasible in engineering applications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

  1. Wang, G., Chen, G., & Bai, F. (2015). Modeling and identification of asymmetric Bouc–Wen hysteresis for piezoelectric actuator via a novel differential evolution algorithm. Sensors and Actuators A: Physical, 235, 105–118.

    Article  Google Scholar 

  2. Guo, Z., Tian, Y., Liu, C., Wang, F., Liu, X., Shirinzadeh, B., et al. (2015). Design and control methodology of a 3-DOF flexure-based mechanism for micro/nano-positioning. Robotics & Computer Integrated Manufacturing, 32, 93–105.

    Article  Google Scholar 

  3. Gao, P., Swei, S., & Yuan, Z. (1999). A new piezodriven precision micropositioning stage utilizing flexure hinges. Nanotechnology, 10, 394–398.

    Article  Google Scholar 

  4. Zhang, Y., & Gong, J. (2000). Structure and parameter design for two degrees of freedom micro-positioning mechanism with large travel. Chinese Journal of Mechanical Engineering, 46(23), 30–35.

    Article  Google Scholar 

  5. Huang, W., Dang, B., Wang, Y., & Wang, Y. (2017). Two-freedom image stabilization institution of large stroke of bidirectional actuation. Optics and Precision Engineering, 25(06), 1494–1501.

    Article  Google Scholar 

  6. Zhu, W., Zhu, Z., Guo, P., & Ju, B. (2018). A novel hybrid actuation mechanism based XY nanopositioning stage with totally decoupled kinematics. Mechanical Systems & Signal Processing, 99, 747–759.

    Article  Google Scholar 

  7. Liu, P., & Yan, P. (2016). A new model analysis approach for bridge-type amplifiers supporting nano-stage design. Mechanism and Machine Theory, 99, 176–188.

    Article  Google Scholar 

  8. Lai, L., & Zhu, Z. (2017). Design, modeling and testing of a novel flexure-based displacement amplification mechanism. Sensors and Actuators A: Physical, 266, 122–129.

    Article  Google Scholar 

  9. Yong, Y., Aphale, S., & Moheimani, S. (2009). Design, identification, and control of a flexure-based XY stage for fast nanoscale positioning. IEEE Transactions on Nanotechnology, 8(1), 46–54.

    Article  Google Scholar 

  10. Yeom, T., Simon, T., Zhang, M., North, M., & Cui, T. (2012). High frequency, large displacement, and low power consumption piezoelectric translational actuator based on an oval loop shell. Sensors and Actuators: A Physical, 176, 99–109.

    Article  Google Scholar 

  11. Chen, J., Zhang, C., Xu, M., Zi, Y., & Zhang, X. (2015). Rhombic micro-displacement amplifier for piezoelectric actuator and its linear and hybrid model. Mechanical Systems and Signal Processing, 50–51, 580–593.

    Article  Google Scholar 

  12. Zhu, Z., Zhou, X., Liu, Z., Wang, R., & Zhu, L. (2014). Development of a piezoelectrically actuated two-degree-of-freedom fast tool servo with decoupled motions for micro-/nanomachining. Precision Engineering, 38(4), 809–820.

    Article  Google Scholar 

  13. Zhang, J., Chen, W., Ke, X., Wei, D., & Hong, T. (2009). Design and simulation of a kind of micro-displacement amplification mechanism. Journal of Machine Design, 26(12), 10–12.

    Google Scholar 

  14. Zhao, H., Bi, S., & Yu, J. (2009). Modeling and analysis of triangle flexible hinge. Journal of Mechanical Engineering, 45(8), 1–5.

    Article  Google Scholar 

  15. Lu, Q., Huang, W., & Sun, M. (2016). Optimization design of amplification mechanism for level flexure hinge based on compliance ratio. Optics and Precision Engineering, 24(1), 102–111.

    Article  Google Scholar 

  16. Lu, Q., Huang, W., Wang, Y., & Sun, M. (2015). Optimization design of deep-notch elliptical flexure hinges. Optics and Precision Engineering, 23(1), 206–215.

    Article  Google Scholar 

Download references

Acknowledgements

This work is supported by the National Natural Science Foundation of China (Grant No. 51505161), China, the Key University Science Research Project of Anhui Province (Grant No. KJ2017A121), China.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiangqiang Zhong.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhong, X., Liu, C., Di, Z. et al. Optimization and Experiment of Two-Dimensional Parallel Decoupling Image Stabilization Mechanism. Int. J. Precis. Eng. Manuf. 21, 1965–1974 (2020). https://doi.org/10.1007/s12541-020-00393-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12541-020-00393-x

Keywords

Navigation