Skip to main content
Log in

Electromagnetic tracking of needle intervention for sacral nerve stimulation using the image-guided surgery toolkit (IGSTK)

  • Published:
International Journal of Precision Engineering and Manufacturing Aims and scope Submit manuscript

Abstract

Sacral nerve stimulation (SNS) is a therapeutic medical procedure that stimulates the sacral nerve using an electrode inserted near the sacral nerve to treat the conditions of overactive bladder and fecal incontinence. The primary challenge in the SNS procedure is that the physician inserts a needle to place an electrode through the narrow structure of the sacrum while relying on fluoroscopic images. We developed a navigation system which relies on an off-the-shelf electromagnetic tracking device, preoperative CT images, and a graphical user interface for needle insertion. Subjects inserted the needle into targets in a free metallic environment and in a surgical environment with a sacral phantom model. The mean registration error in four trials was 0.90±0.081 mm in the free metallic environment and 1.16±0.49 mm in the surgical environment. The mean user error (UE) between the needle tip position and a target was 5.08±1.27 mm in the free metallic environment and 4.26±2.87 mm in the surgical environment. We believe that our navigation system has potential to improve clinical sacral nerve stimulation treatment considerably. To support clinical application of this method, several remaining issues pertaining to the developed navigation system in an in vivo environment must be resolved.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Chai, T. C. and Mamo, G. J., “Modified techniques of S3 foramen localization and lead implantation in S3 neuromodulation,” Urology, Vol. 58, No. 5, pp. 786–790, 2001.

    Article  Google Scholar 

  2. Yoo, D. J., “Three-dimensional human body model reconstruction and manufacturing from CT medical image data using a heterogeneous implicit solid based approach,” Int. J. Precis. Eng. Manuf., Vol. 12, No. 2, pp. 293–301, 2011.

    Article  Google Scholar 

  3. Koenig, T. R., Mettler, F. A., and Wagner, L. K., “Skin injuries from fluoroscopically guided procedures: Part 2, review of 73 cases and recommendations for minimizing dose delivered to patient,” American Journal of Roentgenology, Vol. 177, No. 1, pp. 13–20, 2001.

    Article  Google Scholar 

  4. Tjandra, J. J., Lim, J. F., and Matzel, K., “Sacral nerve stimulation: An emerging treatment for faecal incontinence,” ANZ Journal of Surgery, Vol. 74, No. 12, pp. 1098–1106, 2004.

    Article  Google Scholar 

  5. Cleary, K. and Peters, T. M., “Image-guided interventions: Technology review and clinical applications,” Annual Review of Biomedical Engineering, Vol. 12, No. pp. 119–142, 2010.

    Article  Google Scholar 

  6. Banovac, F., Tang, J., Xu, S., Lindisch, D., Chung, H. Y., and Levy, E. B. et. al, “Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine,” Medical Physics, Vol. 32, No. 8, pp. 2698–2705, 2005.

    Article  Google Scholar 

  7. Banovac, F., Glossop, N., Lindisch, D., Tanaka, D., Levy, E., and Cleary, K., “Liver tumor biopsy in a respiring phantom with the assistance of a novel electromagnetic navigation device,” Proc. of the 5th International Conference on Medical Image Computing and Computer-Assisted Intervention-Part I, pp. 200–207, 2002.

    Google Scholar 

  8. Maier-Hein, L., Tekbas, A., Seitel, A., Pianka, F., Muller, S. A., and Satzl, S., et. al, “In vivo accuracy assessment of a needle-based navigation system for CT-guided radiofrequency ablation of the liver,” Medical Physics, Vol. 35, No. 12, pp. 5385–5396, 2008.

    Article  Google Scholar 

  9. Cleary, K., Ibanez, L., Ranjan, S., and Blake, B. “IGSTK: A software toolkit for image-guided surgery applications,” Proc. of the 18th International Congress and Exhibition — Computer Assisted Radiology and Surgery, Vol. 1268, pp. 473–479, 2004.

    Google Scholar 

  10. Yaniv, Z., Cheng, P., Wilson, E., Popa, T., Lindisch, D., and Campos-Nanez, E. et. al, “Needle-based interventions with the image-guided surgery toolkit (IGSTK): From phantoms to clinical trials,” IEEE Transactions on Biomedical Engineering, Vol. 57, No. 4, pp. 922–933, 2010.

    Article  Google Scholar 

  11. Huynh, L. M. and Kim, Y. H., “A computer-aided and robot-assisted surgical system for reconstruction of anterior cruciate ligament,” Int. J. Precis. Eng. Manuf., Vol. 14, No. 1, pp. 49–54, 2013.

    Article  Google Scholar 

  12. Nixon, M. A., McCallum, B. C., Fright, W. R., and Price, N. B., “The effects of metals and interfering fields and on electromagnetic trackers,” Presence: Teleoperators & Virtual Environments, Vol. 7, No. 2, pp. 204–218, 1998.

    Article  Google Scholar 

  13. Hummel, J., Figl, M., Kollmann, C., Bergmann, H., and Birkfellner, W., “Evaluation of a miniature electromagnetic position tracker,” Medical Physics, Vol. 29, No. 10, pp. 2205–2212, 2002.

    Article  Google Scholar 

  14. Frantz, D. D., Wiles, A. D., Leis, S. E., and Kirsch, S. R., “Accuracy assessment protocols for electromagnetic tracking systems,” Physics in Medicine & Biology, Vol. 48, No. 14, pp. 2241–2251, 2003.

    Article  Google Scholar 

  15. Hummel, J., Figl, M., Birkfellner, W., Bax, M. R., Shahidi, R., Maurer, C. R., and Bergmann, H., “Evaluation of a new electromagnetic tracking system using a standardized assessment protocol,” Physics in Medicine & Biology, Vol. 51, No. 10, pp. 205–210, 2006.

    Article  Google Scholar 

  16. Daneshgari F., “Applications of neuromodulation of the lower urinary tract in female urology,” International Brazilian Journal of Urology, Vol. 32, No. 3, pp. 262–272, 2006.

    Article  Google Scholar 

  17. Schwald, B. and Seibert, H., “Registration tasks for a hybrid tracking system for medical augmented reality,” Journal of WSCG, pp. 411–418, 2004.

    Google Scholar 

  18. Arun, K. S., Huang, T. S., and Blostein, S. D., “Least-squares fitting of two 3-D point sets,” IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. PAMI-9, No. 5, pp. 698–700, 1987.

    Article  Google Scholar 

  19. Fitzpatrick, J. M., West, J. B., and Maurer, C. R., “Predicting error in rigid-body point-based registration,” IEEE Transactions on Medical Imaging, Vol. 17, No. 5, pp. 694–702, 1998.

    Article  Google Scholar 

  20. Arman, C., Naderi, S., Kiray, A., Aksu, F. T., Yilmaz, H. S., and Tetik, S. et. al, “The human sacrum and safe approaches for screw placement,” Journal of Clinical Neuroscience, Vol. 16, No. 8, pp. 1046–1049, 2009.

    Article  Google Scholar 

  21. Khan, M. F., Dogan, S., Maataoui, A., Wesarg, S., Gurung, J., and Ackermann, H. et. al, “Navigation-based needle puncture of a cadaver using a hybrid tracking navigational system,” Investigative Radiology, Vol. 41, No. 10, pp. 713–720, 2006.

    Article  Google Scholar 

  22. Krucker, J., Xu, S., Glossop, N., Viswanathan, A., Borgert, J., Schulz, H., and Wood, B. J., “Electromagnetic tracking for thermal ablation and biopsy guidance: Clinical evaluation of spatial accuracy,” Journal of Vascular and Interventional Radiology, Vol. 18, No. 9, pp. 1141–1150, 2007.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jung Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Na, Y., Seo, JM. & Kim, J. Electromagnetic tracking of needle intervention for sacral nerve stimulation using the image-guided surgery toolkit (IGSTK). Int. J. Precis. Eng. Manuf. 14, 2015–2020 (2013). https://doi.org/10.1007/s12541-013-0274-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12541-013-0274-9

Keywords

Navigation