Abstract
In patients with heart disease, diabetes and age predict adverse outcomes. It remains unclear whether persons with diabetes who have implantable cardioverter defibrillators (ICDs) have fewer appropriate and inappropriate ICD shocks. The objective of this study is to determine if persons with diabetes who have ICDs receive a similar amount of appropriate and inappropriate shocks compared to persons without diabetes. In a post hoc analysis of 1,528 patients enrolled in the INTRINSIC RV trial, all-cause mortality and ICD shocks between persons with and without diabetes, stratified by age, was compared. The relationship between shock and mortality was also assessed. Mortality 1 year after ICD implant was lower for persons without diabetes vs. persons with diabetes (3.5% vs. 7.9%, p < 0.001). Young and old persons with diabetes received a similar number of total and appropriate ICD shocks. However, older persons with diabetes were less likely to receive inappropriate ICD shocks vs. older persons without diabetes (1.9% vs. 6.9%, p < 0.01). ICD shocks were not temporally related to mortality regardless of diabetes status. In the INTRINSIC RV trial, persons with diabetes and older persons without diabetes undergoing ICD implant were at a higher risk of death. Older persons with diabetes received less inappropriate shocks and still had a similar amount of appropriate shocks compared to persons without diabetes of similar age.
Similar content being viewed by others
Abbreviations
- ICD:
-
Implantable cardioverter defibrillator
- NYHA:
-
New York Heart Association
References
Stein, K. M., Mittal, S., Gilliam, F. R., Gilligan, D. M., et al. (2009). Predictors of early mortality in implantable cardioverter-defibrillator recipients. Europace, 11(6), 734–740.
Bunch, T. J., Day, J. D., Olshansky, B., et al. (2009). INTRINSIC RV Study Investigators: Newly detected atrial fibrillation in patients with an implantable cardioverter-defibrillator is a strong risk marker of increased mortality. Heart Rhythm, 6(1), 2–8.
Cygankiewicz, I., Gillespie, J., Zareba, W., et al. (2009). MADIT II Investigators. Predictors of long-term mortality in Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) patients with implantable cardioverter-defibrillators. Heart Rhythm, 6(4), 468–473.
Lin, E. H., Heckbert, S. R., Rutter, C. M., Katon, W. J., Ciechanowski, P., Ludman, E. J., et al. (2009). Depression and increased mortality in diabetes: Unexpected causes of death. Annals of Family Medicine, 7(5), 414–421.
Parappil, A., Depczynski, B., Collett, P., & Marks, G. B. (2010). Effect of comorbid diabetes on length of stay and risk of death in patients admitted with acute exacerbations of COPD. Respirology, 15(6), 918–922.
Preis, S. R., Hwang, S. J., Coady, S., et al. (2009). Trends in all-cause and cardiovascular disease mortality among women and men with and without diabetes mellitus in the Framingham Heart Study, 1950 to 2005. Circulation, 119(13), 1728–1735.
Wittenberg, S. M., Cook, J. R., & Hall, W. J. (2005). Comparison of efficacy of implanted cardioverter-defibrillator in patients with versus without diabetes mellitus. The American Journal of Cardiology, 96(3), 417–419.
Whang, W., & Bigger, J. T., Jr. (2000). Diabetes and outcomes of coronary artery bypass graft surgery in patients with severe left ventricular dysfunction: Results from The CABG Patch Trial database. The CABG Patch Trial Investigators and Coordinators. Journal of the American College of Cardiology, 36(4), 1166–1172.
Olshansky, B., Day, J. D., Moore, S., et al. (2007). Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study. Circulation, 115(1), 9–16.
Olshansky, B., Day, J., McGuire, M., et al. (2006). Reduction of right ventricular pacing in patients with dual-chamber ICDs. Pacing and Clinical Electrophysiology, 29(3), 237–243.
Bhavnani, S. P., Kluger, J., Coleman, C. I., et al. (2010). Prognostic impact of shocks for clinical and induced arrhythmias on morbidity and mortality among patients with implantable cardioverter-defibrillators. Heart Rhythm, 7(6), 755–760.
Poole, J. E., Johnson, G. W., Hellkamp, A. S., et al. (2008). Prognostic importance of defibrillator shocks in patients with heart failure. The New England Journal of Medicine, 359(10), 1009–1017.
Desai, H., Aronow, W. S., Ahn, C., et al. (2010). Risk factors for appropriate cardioverter-defibrillator shocks, inappropriate cardioverter-defibrillator shocks, and time to mortality in 549 patients with heart failure. The American Journal of Cardiology, 105(9), 1336–1338.
Levy, W. C., Lee, K. L., Hellkamp, A. S., et al. (2009). Maximizing survival benefit with primary prevention implantable cardioverter-defibrillator therapy in a heart failure population. Circulation, 120(10), 835–842.
Lee, D. S., Tu, J. V., Austin, P. C., et al. (2007). Effect of cardiac and noncardiac conditions on survival after defibrillator implantation. Journal of the American College of Cardiology, 49(25), 2408–2415.
Sandesara, C. M., Roodneshin, H., Sbaity, S., et al. (2008). Antiarrhythmic effects of statins in heart failure. Heart Failure Clinics, 4(2), 187–200.
Chen-Scarabelli, C., & Scarabelli, T. M. (2007). Abstract 1534: Diabetes mellitus is an independent predictor of mortality in defibrillator recipients. Circulation, 116, II_318.
Olshansky, B., Telfer, E. A., Curtis, A. B., et al. (2000). Predictive value of preoperative left ventricular ejection fraction and functional class for mortality and morbidity after high-risk coronary artery bypass grafting. The American Journal of Cardiology, 85(12), 1489–1491. A7.
Gula, L. J., Klein, G. J., Hellkamp, A. S., et al. (2008). Ejection fraction assessment and survival: An analysis of the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT). American Heart Journal, 156(6), 1196–1200.
Wathen, M. S., Sweeney, M. O., DeGroot, P. J., et al. (2001). Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation, 104(7), 796–801.
Saeed, M., Neason, C. G., Razavi, M., et al. (2010). Programming antitachycardia pacing for primary prevention in patients with implantable cardioverter defibrillators: Results from the PROVE Trial. Journal of Cardiovascular Electrophysiology, in press. doi:10.1111/j.1540-8167.2010.01825.x.
Acknowledgments
The authors thank the INTRINSIC RV patients, investigators, and institutions for their participation.
Funding Sources
This study was funded by Boston Scientific CRM.
Author information
Authors and Affiliations
Corresponding author
Additional information
Clinical Trials.org ID: NCT00148967
Supported by a grant from Boston Scientific Corporation
Rights and permissions
About this article
Cite this article
Sandesara, C.M., Sullivan, R.M., Russo, A.M. et al. Older Persons with Diabetes Receive Fewer Inappropriate ICD Shocks: Results from the INTRINSIC RV Trial. J. of Cardiovasc. Trans. Res. 4, 27–34 (2011). https://doi.org/10.1007/s12265-010-9236-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12265-010-9236-0