The objective of this investigation is to study the effectiveness of anodized surface of commercial purity titanium (Cp-Ti) on its corrosion behaviour in simulated body fluid (SBF) and proliferation of osteoblast cells on it, to assess its potentiality as a process of surface modification in enhancing corrosion resistance and osseointegration of dental implants. Highly ordered nano-porous oxide layer, with nano-sized pores, is developed on the surface of Cp-Ti through electrochemical anodization in the electrolyte of aqueous solution of 0·5% HF at 15 V for 30 min at 24 °C. The nano-porous feature of the anodized surface is characterized by field-emission scanning electron microscope (FESEM). Pores of some anodized samples are sealed by exposing the anodized surface in boiling water. Corrosion behaviour of the anodized specimen is studied in Ringer’s solution at 30 ± 2 °C, using electrochemical impedance and cyclic polarization technique. Biocompatibility of the anodized surface is accessed using MG63 osteoblast cells. Both corrosion as well as pitting resistance of Cp-Ti in simulated body fluid are found to be highest in the anodized and sealed condition and followed in decreasing order by those of anodized and unanodized ones. Significantly higher MG63 osteoblast cell proliferations are found on the anodized surface than that on the unanodized one. Anodized Cp-Ti develops nano-size surface pores, like that of natural bone. It enhances corrosion and pitting resistance and also the process of osteoblast cell proliferation on Cp-Ti.
Similar content being viewed by others
References
Arnold M, Cavalcanti-Adam E A, Glass R, Blummel J, Eck W, Kantlehnar M, Kessler H and Spatz J P 2004 Chem. Phys. Chem. 5 383
Baxter I C, Frauchiger V, Textor M, Gwynn I and Richards R G 2002 Eur. Cell Mater. 4 1
Brunette D M and Chehroudi B 1999 J. Biomech. Eng. 121 49
Brunette D M (ed.) 2001 Titanium in medicine: Material science, surface science, engineering biological responses and medical application (Germany: Springer)
Cai Q Y, Varghese O K, Paulose M, Mukherjee N and Grimes C A 2005 J. Mater. Res. 20 230
Campos D M, Santos J R, Kuromoto N K and Soares G A 2007 Rev. Mater. 12 150
Chang Y, Elliott B, Slamovich and Thomas J W 2005 Mater. Res. Soc. Symp. Proc. 845 215
Das K, Bose S and Bandyopadhyay A 2007 Acta Biomater. 3 573
Eliades T 1997 Int. J. Oral Max. Impl. 12 621
Grimes C A, Gong D J, Varghese O K, Thi W, Singh R S, Dickey E C and Hen Z 2001 J. Mater. Res. 16 3331
Huang C, Xie Y, Zhou L and Huang H 2009 Smart Mater. Struct. 18 024003
Jacobs J J, Gilbert J L and Urban R M 1998 J. Bone Joint Surg. Am. 80 268
Jiang X P, Wang X Y, Li J X, Li DY, Man C S, Shepard M J and Zhai T 2006 Mater. Sci. Eng. 429 30
Keller J C, Stanford C M, Wightam J P, Draughn R A and Zaharias R 1994 J. Biomed. Mater. Res. 28 939
Kieswetter K, Schwartz Z, Dean D O and Boyan B D 1996 Crit. Rev. Oral Biol. Med. 7 329
Li X, Guangfu Y, Danhong Y, Xiaoming L and Zhongbing H 2010 J. Mater. Sci. Mater. Med. 21 259
Park J, Bauer S, Vonder Mark K and Schmuki P 2007 Nano Lett. 7 1686
Shabalovskaya S A 2002 Biomed. Mater. Eng. 12 69
Shukla A K, Balasubramaniam R and Bhargava S 2005 Intermetallics 13 631
White K C, Svare C W and Taylor T D 1985 J. Prosthet. Dent. 53 815
Acknowledgements
The authors would like to thank Dr Ajit Sodhi, Department of Biotechnology, Faculty of Science, BHU, and Mr Rajeev Pandey, for their eventful cooperation and help in cell growth study.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
SINGH, A., SINGH, B.P., WANI, M.R. et al. Effect of anodization on corrosion behaviour and biocompatibility of Cp-titanium in simulated body fluid. Bull Mater Sci 36, 931–937 (2013). https://doi.org/10.1007/s12034-013-0536-2
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12034-013-0536-2