Effect of harmonic distortion on electric energy meters of different metrological principles

  • Research Article
  • Published:
Frontiers in Energy Aims and scope Submit manuscript

Abstract

This paper deals with the errors of electric energy metering devices as a result of distortions in the shape of the curves of voltage and current load. It is shown and proved that the errors in energy measurements depend on the design and the algorithms used in electricity meters. There are three main types of metering devises having different principles: inductive (electro-mechanical), electronic static, and digital electronic (microprocessor). Each of these types has its measuring features. Some devices take into account all the harmonic distortions and the constant component which occur in the network while others measure the power and energy values of the fundamental harmonic only. Such traits lead to the discrepancies in the readings of commercial electric energy meters of different types. Hence, the violations in the measurement system unity occur, and a significant error can be observed in the balance of transmitted/consumed electric energy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Baryshev U A, Vostroknutov N N. The basic properties of the errors of modern electricity meters. Kompetentnost, 2015, (4): 42–49

    Google Scholar 

  2. Chapman D. Harmonics Causes and Effect. ECI Publication, No Cu0119, 2011

    Google Scholar 

  3. Chou C J, Liu C C. Analysis of the performance of induction watthour meters in presence of harmonics. Electric Power Systems Research, 1995, 32(1): 71–79

    Article  Google Scholar 

  4. Bul B K. The influence of higher harmonics on operation of induction-overcurrent relays with short turns. Automation and Telemechanics, 1939, (5): 3–14

    Google Scholar 

  5. Chou C J, Liu C C. Harmonic compensation of induction watthour meter performance. Electric Power Systems Research, 1995, 32(2): 89–99

    Article  Google Scholar 

  6. Morva G, Volokhin V, Diahovchenko I. Analysis of the impact of nonlinear distortion in voltage and current curves on the errors of electric energy metering devices. In: 2017 IEEE First Ukraine Conference on Electrical and Computer Engineering, Kyiv, Ukraine, 2017, 528–533

    Chapter  Google Scholar 

  7. Volokhin V, Diahovchenko I. Peculiarities of current sensors used in contemporary electric energy metering devices. Energetika, 2017, 63(1): 8–15

    Google Scholar 

  8. State Standard 13109–97. Quality Norms of Electric Energy in Power Supply Systems of General Purpose. Moscow: Standartinform Publication, 1999

    Google Scholar 

  9. Stevanović D, Petković P. A single-point method for identification sources of harmonic pollution applicable to standard power meters. Electrical Engineering, 2015, 97(2): 165–174

    Article  Google Scholar 

  10. Arseneau R, Filipski P. A calibration system for evaluating the performance of harmonic power analyzers. IEEE Transactions on Power Delivery, 1995, 10(3): 1177–1182

    Article  Google Scholar 

  11. Fassbinder S. Power Quality Application Guide. Harmonics: Passive Filters. Dusseldorf: DeutschesKupferinstitut, 2003

    Google Scholar 

  12. Fink D G, Wayne B H. Handbook for Electrical Engineers, 11th ed. New York: McGraw Hill, 2000

    Google Scholar 

  13. Campbell G, Foster R. Fourier Integrals for Practical Applications. New York: D. Van Nostrand Company Incorporated, 1948

    MATH  Google Scholar 

  14. Wilczyński E. Total apparent power of the electrical system for periodic, deformed waveforms. IEE Proceedings–Electric Power Applications, 2000, 147(4): 281–285

    Article  Google Scholar 

  15. Fassbinder S. Power Quality Application Guide. Harmonics: Capacitors in Harmonic-Rich Environments. Dusseldorf: Deutsches Kupferinstitut, 2004

    Google Scholar 

  16. Folland G B. Real Analysis: Modern Techniques and Their Applications, 2nd ed. New York: Wiley, 1999

    MATH  Google Scholar 

  17. Volokhin V, Diahovchenko I, Kurochkina V, Kanalik M. The influence of nonsinusoidal supply voltage on the amount of power consumption and electricity meter readings. Energetika, 2017, 63 (1): 1–7

    Google Scholar 

  18. Benchabane F, Titaouine A, Bennis O, Yahia K, Taibi D. Direct field oriented control scheme for space vector modulated AC/DC/AC converter fed induction motor. Frontiers in Energy, 2012, 6(2): 129–137

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Illia Diahovchenko.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Diahovchenko, I., Volokhin, V., Kurochkina, V. et al. Effect of harmonic distortion on electric energy meters of different metrological principles. Front. Energy 13, 377–385 (2019). https://doi.org/10.1007/s11708-018-0571-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11708-018-0571-1

Keywords

Navigation