Skip to main content
Log in

A unified power electronic controller for wind driven grid connected wound rotor induction generator using line commutated inverter

  • Research Article
  • Published:
Frontiers in Energy Aims and scope Submit manuscript

Abstract

The implementation of a simple power converter for a wound rotor induction generator employing a three phase diode bridge rectifier and a line commutated inverter in the rotor circuit for super synchronous speeds has been proposed. The detailed working of the system in power smoothing mode and maximum power point tracking mode is presented. The current flow in the rotor circuit is controlled (by controlling the firing angle of the line commutated inverter) for controlling the stator power in both the modes. An 8 bit PIC microcontroller has been programmed to vary the firing angle of the line commutated inverter. Experiments have been carried out on a 3-phase, 3.73 kW, 400 V, 50 Hz, 4-pole, 1500 r/min wound rotor induction generator and the results obtained with the generator supplying power in both the modes are furnished. The complete scheme has been modeled using MATLAB/SIMULINK blocks and a simulation study has been conducted. The experimental waveforms are compared with the simulation results and a very close agreement between them is observed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Salameh Z, Wang S. Microprocessor control of double output induction generator. Part I: inverter firing circuit. IEEE Power Engineering Review, 1989, 9(6): 41–42

    Article  Google Scholar 

  2. Raina G, Malik O P. Wind power system using an adaptive sherbius induction machine. IEEE Transactions on Aerospace and Electronic Systems, 1986, 22(2): 204–210

    Article  Google Scholar 

  3. Uctug M Y, Eskandarzadeh I, Ince H. Modelling and output power optimisation of a wind turbine driven double output induction generator. IEE Proceedings on Electric Power Applications, 1994, 141(2): 33–38

    Article  Google Scholar 

  4. Cadirci I, Ermis M. Communication angle analysis of a double output induction generator operating in sub- and super-synchronous modes. In: Proceedings of the 7th Mediterranean Electrotechnical Conference. Antalya, Turkey, 1994, 793–796

  5. Cadirei I, Ermis M. Performance evaluation of a wind driven DOIG using a hybrid model. IEEE Transactions on Energy Conversion, 1998, 13(2): 148–155

    Article  Google Scholar 

  6. Cadirci I, Ermis M. Double-output induction generator operating at subsynchronous and supersynchronous speeds: steady-state performance optimisation and wind-energy recovery. IEE Proceedings on Electric Power Applications, 1992, 139(5): 429–442

    Article  Google Scholar 

  7. Refoufi L, Al Zahawi B A T, Jack A G. Analysis and modeling of the steady state behavior of the static Kramer induction generator. IEEE Transactions on Power Systems, 1999, 14(3): 333–339

    Google Scholar 

  8. De Battista H, Puleston P F, Mantz R J, Christiansen C F. Sliding mode control of wind energy systems with DOIG-power efficiency and torsional dynamics optimization. IEEE Transactions on Power Systems, 2000, 15(2): 728–734

    Article  Google Scholar 

  9. Datta R, Ranganathan V T. A method of tracking the peak power points for a variable speed wind energy conversion system. IEEE Transactions on Energy Conversion, 2003, 18(1): 163–168

    Article  Google Scholar 

  10. Yang T C. Initial study of using rechargeable batteries in wind power generation with variable speed induction generators. IET Renewable Power Generation, 2008, 2(2): 89–101

    Article  MATH  Google Scholar 

  11. Cardenas R, Pena R, Asher G, Clare J. Power smoothing in wind generation systems using a sensorless vector controlled induction Machine driving a flywheel. IEEE Transactions on Energy Conversion, 2004, 19(1): 206–216

    Article  Google Scholar 

  12. Cardenas R, Pena R, Asher G M, Clare J, Blasco-Gimenez R. Control strategies for power smoothing using a flywheel driven by a sensorless vector-controlled induction machine operating in a wide speed range. IEEE Transactions on Industrial Electronics, 2004, 51(3): 603–614

    Article  Google Scholar 

  13. Takahashi R, Kinoshita H, Murata T, Tamura J, Sugimasa M, Komura A, Futami M, Ichinose M, Ide K. Output power smoothing and hydrogen production by using variable speed wind generators. IEEE Transactions on Industrial Electronics, 2010, 57(2): 485–493

    Article  Google Scholar 

  14. Qu L Y, Qiao W. Constant power control of DFIG wind turbines with supercapacitor energy storage. IEEE Transactions on Industry Applications, 2011, 47(1): 359–367

    Article  MathSciNet  Google Scholar 

  15. Fadaeinedjad R, Moallem M, Moschopoulos G. Simulation of a wind turbine with doubly fed induction generator by FAST and Simulink. IEEE Transactions on Energy Conversion, 2008, 23(2): 690–700

    Article  Google Scholar 

  16. Papathanassiou S A, Papadopoulos M P. Mechanical stresses in fixed-speed wind turbines due to network disturbances. IEEE Transactions on Energy Conversion, 2001, 16(4): 361–367

    Article  Google Scholar 

  17. Johnson C C, Smith R T. Dynamics of wind generators on electric utility networks. IEEE Transactions on Aerospace and Electronic Systems, 1976, 12(4): 483–493

    Article  Google Scholar 

  18. Beltran B, Ahmed-Ali T, El Hachemi Benbouzid M. Sliding mode power control of variable-speed wind energy conversion systems. IEEE Transactions on Energy Conversion, 2008, 23(2): 551–558

    Article  Google Scholar 

  19. Beltran B, Benbouzid M E H, Ahmed-Ali T. Second-order sliding mode control of a doubly fed induction generator driven wind turbine. IEEE Transactions on Energy Conversion, 2012, 27(2): 261–269

    Article  Google Scholar 

  20. Wasynczuk O. Analysis of line-commutated converters during unbalanced operating conditions. IEEE Transactions on Energy Conversion, 1994, 9(2): 420–426

    Article  Google Scholar 

  21. Ammasaigounden N, Subbiah M. Microprocessor-based voltage controller for wind-driven induction generators. IEEE Transactions on Industrial Electronics, 1990, 37(6): 531–537

    Article  Google Scholar 

  22. Moon G W. Predictive current control of distribution static compensator for reactive power compensation. IEE Proceedings. Generation, Transmission and Distribution, 1999, 146(5): 515–520

    Article  Google Scholar 

  23. Dixon J, Moran L, Rodriguez J, Domke R. Reactive power compensation technologies: state-of-the-art review. Proceedings of the IEEE, 2005, 93(12): 2144–2164

    Article  Google Scholar 

  24. Bilgin H F, Ermis M, Kose K N, Cetin A, Cadirci I, Acik A, Demirci T, Terciyanli A, Kocak C, Yorukoglu M. Reactive-power compensation of coal mining excavators by using a new-generation STATCOM. IEEE Transactions on Industry Applications, 2007, 43(1): 97–110

    Article  Google Scholar 

  25. Mahanty R. Large value AC capacitor for harmonic filtering and reactive power compensation. IET Generation Transmission & Distribution, 2008, 2(6): 876–891

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. Ammasai Gounden.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Binu Ben Jose, D.R., Ammasai Gounden, N. & Sri Naga Ramesh, R. A unified power electronic controller for wind driven grid connected wound rotor induction generator using line commutated inverter. Front. Energy 7, 39–48 (2013). https://doi.org/10.1007/s11708-012-0229-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11708-012-0229-3

Keywords

Navigation