Effects of diffuser vane geometry on interaction noise generated from a centrifugal compressor

  • Published:
Journal of Thermal Science Aims and scope Submit manuscript

Abstract

The characteristics of interaction tone noise radiated from a centrifugal compressor with a vaned diffuser are discussed by experiments, including visualization techniques using the oil-film method. Research attention is paid to the leading edge geometries of the diffuser vanes that are deeply related to the generation mechanism of the interaction tone noise. The compressor-radiated noise can be reduced by several decibels by setting some clearances in both the hub and shroud surfaces of the diffuser wall along with some decline in the pressure-rise coefficient. Since the decline turned out to be caused by the flow impingement and also by the secondary flow within the diffuser passages, several new types of diffuser vane geometries which do not detract from both the performance and noise level are developed and utilized for the experiments. The presented diffuser vane geometries will offer a few basic guidelines for the diffuser vane design.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Morfey, C L. Rotating Pressure Patterns in Ducts, Their Generation and Transmission. Journal of Sound and Vibration, 1964, 1: 60–87

    Article  MATH  ADS  Google Scholar 

  2. Kobayashi, H, et al. Noise in Centrifugal Compressor, 1st Report: Influence of the Diffuser Vane on Noise (in Japanese). Trans. of the JSME (B), 1996, 62(598): 2303–2309

    Google Scholar 

  3. Sugimura, S, Watanabe, M. A Study on Suppressing Acoustic Resonance of Interaction Tones from a Centrifugal Motor Blower (in Japanese). Trans. of the JSME (B), 2000, 66(650): 2606–2612

    Google Scholar 

  4. Ohta, Y, Outa, E, Tajima, K. Evaluation and Prediction of Blade-Passing Frequency Noise Generated by a Centrifugal Blower. Trans. of the ASME, Journal of Turbomachinery, 1996, 118: 597–605

    Article  Google Scholar 

  5. Ohta, Y, et al. Frequency-Response Characteristics of Interaction Tone Noise Radiated from a Centrifugal Compressor. ASME FEDSM2003-45093, 2003. 1–6

  6. Ohta, Y, et al. Frequency-Response Characteristics of Centrifugal Compressor Noise. In: Proc. of the 33rd International Congress and Exposition on Noise Control Engineering, Prague, Czech Republic, 2004. 1–8

  7. Tyler, J M, Sofrin, T G. Axial Flow Compressor Noise Studies. Society of Automotive Engineers Transactions, 1962, 70: 309–332

    Google Scholar 

  8. Eck, B. Design and Operation of Centrifugal, Axial-flow and Cross-flow Fans. Oxford, U.K.: Pergamon Press, 1972

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ohta, Y., Takehara, N., Okutsu, Y. et al. Effects of diffuser vane geometry on interaction noise generated from a centrifugal compressor. J. of Therm. Sci. 14, 321–328 (2005). https://doi.org/10.1007/s11630-005-0052-9

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11630-005-0052-9

Keywords

CLC number

Navigation