Ratiometric measurement of intracellular pH of cultured cells with BCECF in a fluorescence multi-well plate reader

  • Cellular Models
  • Published:
In Vitro Cellular & Developmental Biology - Animal Aims and scope Submit manuscript

Summary

A number of methods have been developed to measure intracellular pH (pHi) because of its importance in intracellular events. A major advance in accurate pHi measurement was the development of the ratiometric fluorescent indicator dye, 2′,7′-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF). We have used a fluorescence multi-well plate reader and a ratiometric method for determining pHi in primary cultures of rabbit corneal epithelial (CE) cells with BCECF. Fluorescence was measured at excitation wavelengths of 485±11 nm and 395±12.5 nm, with emission detected at 530±15 nm. Cells grown in multi-well plates were loaded with 4 µM BCECF for 30 min at 37° C. Resting pHi was 7.34±0.03 (2 cultures, N=5 wells). Changes in pHi determined with the fluorescence multi-well plate reader after the addition and removal of NH4Cl or sodium lactate were comparable to changes in cells analyzed with a digitized fluorescence imaging system. A concentration-response relationship involving changes in pHi was easily demonstrated in CE cells after treatment with ionomycin, a calcium ionophore. Low doses of ionomycin (2.5–5 µM), produced a prolonged acidification; 7.5 µM ionomycin produced a transient acidification; and 10 µM ionomycin resulted in a slight alkalinization. We conclude that accurate pHi measurements can be obtained with a ratiometric method with BCECF in a multi-well plate reader. This technology may simplify screening studies evaluating effects of hormones, growth factors, or toxicants on pHi homeostasis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Bright, G. R.; Fisher, G. W.; Rogowska, J., et al. Fluorescence ratio imaging microscopy. Methods Cell Biol. 30:157–192; 1989.

    Article  PubMed  CAS  Google Scholar 

  2. Busa, W. B.; Nuccitelli, R. Metabolic regulation via intracellular pH. Am. J. Physiol. 246:R409-R438; 1984.

    PubMed  CAS  Google Scholar 

  3. Grant, R. L.; Acosta, D. A rapid, accurate method to determine intracellular pH using a fluorescence multiplate reader. FASEB J. 8:A649; 1994.

  4. Grant, R. L.; Acosta, D. Interactions of intracellular pH and intracellular calcium in primary cultures of rabbit corneal epithelial cells. In Vitro Cell. Dev. Biol. 32:38–45; 1996.

    CAS  Google Scholar 

  5. Grant, R. L.; Yao, C.; Gabaldon, D., et al. Evaluation of surfactant cytotoxicity potential by primary cultures of ocular tissues: I. Characterization of rabbit corneal epithelial cells and initial injury and delayed toxicity studies. Toxicology 76:153–176; 1992.

    Article  PubMed  CAS  Google Scholar 

  6. Mahnensmith, R. L.; Aronson, P. S. The plasma membrane sodium-hydrogen exchanger and its role in physiological and pathophysiological processes. Circulation Res. 56:773–788; 1985.

    PubMed  CAS  Google Scholar 

  7. Rink, T. J.; Tsien, R. Y.; Pozzan, T. Cytoplasmic pH and free Mg2+ in lymphocytes. J. Cell. Biol. 95:189–196; 1982.

    Article  PubMed  CAS  Google Scholar 

  8. Roos, A.; Boron, W. F. Intracellular pH. Physiol. Rev. 61:296–434; 1981.

    PubMed  CAS  Google Scholar 

  9. Slotki, I.; Schwartz, J. H.; Alexander, E. A. Interrelationship between cell pH and cell calcium in rat inner medullary collecting duct cells. Am. J. Physiol. 265:C432-C438; 1993.

    PubMed  CAS  Google Scholar 

  10. Thomas, J. A.; Buchsbaum, R. N.; Zimniak, A., et al. Intracellular pH measurements in Ehrlich Ascites tumor cells utilizing spectroscopic probes generated in situ. Biochemistry 18:2210–2218; 1979.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Grant, R.L., Acosta, D. Ratiometric measurement of intracellular pH of cultured cells with BCECF in a fluorescence multi-well plate reader. In Vitro Cell.Dev.Biol.-Animal 33, 256–260 (1997). https://doi.org/10.1007/s11626-997-0044-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11626-997-0044-z

Key words

Navigation