Abstract
Purpose
This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers.
Materials and methods
Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student’s t test was used to detect a meaningful difference of 3 mm in between the two methods.
Results
A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm (p=0.001), 3 mm [p=not significant (ns)], and 3 mm (p=ns), respectively.
Conclusions
Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.
Riassunto
Obiettivo
Scopo del presente lavoro è stato studiare il ruolo dei marcatori fiduciali nell’irradiazione parziale della mammella guidata dalle immagini (IG-PBI) e confrontare gli spostamenti basati sui reperi ossei rispetto ai marcatori fiduciali.
Materiali e metodi
Sono state sottoposte a IG-PBI 15 pazienti. Al momento della chirurgia sono stati posizionati tre marcatori fiduciali nel letto tumorale. Prima di ogni frazione giornaliera di radioterapia sono state ottenute immagini kV ortogonali e confrontate con le radiografie ricostruite digitalmente, utilizzando come riferimento reperi ossei e marcatori fiduciali. è stato utilizzato il test t di Student per identificare differenze significative di 3 mm tra i due metodi.
Risultati
Sono state studiate 105 sessioni di radioterapia guidata dalle immagini (IGRT). Gli spostamenti medi nella direzione superiore/inferiore, destra/sinistra e anteriore/posteriore ottenuti utilizzando i reperi ossei vs. i marcatori fiduciali sono risultati di 2 mm [deviazione standard (SD) 10 m] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), e 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), rispettivamente. La differenza media in valore assoluto tra gli spostamenti ottenuti con i due metodi nelle direzioni superiore/inferiore, destra/sinistra e anteriore/ posteriore sono risultati di 5 mm (p=0,001), 3 mm [p=non significativo (ns)], e 3 mm (p=ns), rispettivamente.
Conclusioni
L’ utilizzo di marcatori fiduciali nella IG-PBI permette di migliorare l’accuratezza del set-up rispetto all’allineamento basato sui reperi ossei, in particolare nella direzione superiore/inferiore.
Similar content being viewed by others
References/Bibliografia
Veronesi U, Cascinelli N, Mariani L et al (2002) Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer. N Engl J Med 347:1227–1232
Fisher B, Anderson S, Bryant J et al (2002) Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer. N Engl J Med 347:1233–1241
Baglan KL, Sharpe MB, Jaffray D et al (2003) Accelerated Partial Breast Irradiation Using 3D Conformal Radiation Therapy (3D-CRT). Int J Radiat Oncol Biol Phys 55:302–311
Vicini F, Remouchamps M, Wallace M et al (2003) Ongoing clinical experience utilizing 3D conformal external beam radiotherapy to deliver partial breast irradiation in patients with early stage breast cancer treated with breast conserving therapy. Proc Am Soc Radiol Oncol 57:364
Dawson LA, Sharpe MB (2006) Imageguided radiotherapy: rationale, benefits, and limitations. Lancet Oncol 7:848–858
Leonard CE, Tallhamer M, Johnson T et al (2010) Clinical experience with image-guided radiotherapy in an accelerated partial breast intensitymodulated radiotherapy protocol. Int J Radiat Oncol Biol Phys 76:528–534
Trovo M, Sartor G, Chiovati P et al (2010) Forward Intensity Modulated Radiation Therapy for Partial Breast Irradiation Confers High Dose Homogeneity and Conformation to the Target Volume. Int J Radiat Oncol Biol Phys 78:S747
White EA, Cho J, Vallis KA et al (2007) Cone beam computed tomography guidance for setup of patients receiving accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys 68:547–554
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Trovo, M., Polesel, J., Biasutti, C. et al. Fiducial markers for image-guided partial breast irradiation. Radiol med 118, 1212–1219 (2013). https://doi.org/10.1007/s11547-013-0967-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11547-013-0967-2