The foetal heart rate (FHR) response to uterine contractions is crucial to detect foetal distress by electronic FHR monitoring during labour. We are developing a new automated system (OxSys) for decision support in labour, using the Oxford database of intrapartum FHR records. We describe here a novel technique for automated detection of uterus contractions. In addition, we present a comparison of the new method with four other computerised approaches. During training, OxSys achieved sensitivity above 95% and positive predictive value (PPV) of up to 90% for traces of good quality. During testing, OxSys achieved sensitivity = 87% and PPV = 75%. For comparison, a second clinical expert obtained sensitivity = 93% and PPV = 80%, and all other computerised approaches achieved lower values. It was concluded that the proposed method can be employed with confidence in our study on foetal health assessment in labour and future OxSys development.
References
Ayres-de-Campos D, Bernardes J, Garrido A, Marques-de-sá J, Pereira-Leite L (2000) SisPorto 2.0: a program for automated analysis of cardiotocograms. J Matern Fetal Neonatal Med 9:311–318
Cazares S, Moulden M, Redman CWG, Tarassenko L (2001) Tracking poles with autoregressive model: a confidence index for the analysis of the intrapartum cardiotocogram. Med Eng Phys 23:603–614
Cazares S (2002) Automated identification of abnormal patterns in the intrapartum cardiotocogram (dissertation). University of Oxford, UK
Chung TKH, Mohajer MP, Yang ZJ, Chang AMZ, Sahota DS (1995) The prediction of foetal acidosis at birth by computerized analysis of intrapartum cardiotocography. BJOG 102:454–460
Cohen J (1960) A coefficient of agreement for nominal scales. Educ Psychol Meas 20:37–46
Dawes GS, Houghton R, Redman CWG, Visser GHA (1982) The pattern of the normal human foetal heart rate. BJOG 89:276–284
Dawes GS, Moulden M, Redman CWG (1991) System 8000: computerized antenatal FHR analysis. J Perinat Med 19:47–51
Freeman R (2003) Foetal heart rate monitoring, 3rd edn. Williams and Wilkins, Philadelphia
Glover F, Kochenberger GA (eds) (2002) Handbook of meta-heuristics, Kluwer Academic Publishers, Boston
Hamilton E, Kimanani K (1994) Intrapartum prediction of foetal status and assessment of labour progress. Baillieres Clin Obstet Gynaecol 8:567–581
Keith R (1993) Intelligent foetal monitoring and decision support in the management of labour (dissertation), University of Plymouth, UK
Maeda K, Utsu M, Makio A, Serizawa M, Noguchi Y, Hamada T et al (1998) Neural network computer analysis of foetal heart rate. J Matern Fetal Investig 8:163–171
Pello LC, Rosevear SK, Dawes GS, Moulden M, Redman CWG (1991) Computerized foetal heart analysis in labour. J Obstet Gynaecol 78:602–610
Strachan B, Sahota DS, Wijngaarden WJ, James DK, Chang A (2001) Computerised analysis of the foetal heart rate and relation to acidaemia at delivery. BJOG 108:848–852
Taillard ÉD, Waelti P, Zuber J (2008) Few statistical tests for proportions comparison. Eur J Oper Res 185:1336–1350
Acknowledgments
We would like to express our sincere gratitude to Linda Holden and Mary Moulden from the JR Hospital (Oxford) for producing the reference set. This study has been supported in part by the Oxford National Institute for Health Research (NIHR) Biomedical Research Centre Program.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Georgieva, A., Payne, S.J. & Redman, C.W.G. Computerised electronic foetal heart rate monitoring in labour: automated contraction identification. Med Biol Eng Comput 47, 1315–1320 (2009). https://doi.org/10.1007/s11517-009-0538-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-009-0538-9