Abstract
Uniaxial tensile experiments are commonly used to evaluate the mechanical properties of engineered vascular tissues. We consider a typical uniaxial tensile experiment on a ring-shaped specimen and the corresponding theoretical framework within which the experimental data are processed when the sample undergoes a finite deformation. In some cases when the material is considered to be elastic, isotropic and incompressible, data obtained from a ring test can be processed to identify constitutive stress–strain relations via a strain energy function (SEF). Accurate identification of the SEF requires that the experimentally recorded deformations are acquired from a region sufficiently far away from the material-grip interface to minimize the confounding effects of friction and bending. Image-based tracking of surface markers provides a method by which the deformation of the ring sample can be locally recorded when subjected to uniaxial extension. We present an illustrative example of a uniaxial ring experiment on an engineered vascular tissue construct, and process the obtained data to identify the SEF. The SEF is used to perform a finite-element based computational simulation of the ring experiment, which is used to better understand the inherent errors and artifacts which may confound accurate data acquisition and correspondingly SEF identification. The obtained computational results provide guidance on the location of surface markers that facilitate accurate measure of local sample deformation for a range of materials.
Similar content being viewed by others
References
Azuma T, Hasegawa M (1971) A rheological approach to the architecture of arterial walls. Jpn J Physiol 21(1):27
Cox RH (1983) Comparison of arterial wall mechanics using ring and cylindrical segments. Am J Physiol Heart Circ Physiol 244(2):H298–H303
Dignan RJ, Yeh T Jr, Dyke CM, Lutz HA III, Wechsler AS (1992) The influence of age and sex on human internal mammary artery size and reactivity. Ann Thorac Surg 53(5):792–797
Hoeltzel DA, Buzard K, K-i C, Altman P (1992) Strip extensiometry for comparison of the mechanical response of bovine, rabbit, and human corneas. J Biomech Eng 114(2):202–215
Sokolis D (2007) Passive mechanical properties and structure of the aorta: segmental analysis. Acta Physiol 190(4):277–289
Tanaka TT, Fung Y-C (1974) Elastic and inelastic properties of the canine aorta and their variation along the aortic tree. J Biomech 7(4):357–370
Y. Fung Biomechanics: mechanical properties of living tissues. 1993. Springer-Verlag, New York
Holzapfel GA, Sommer G, Gasser CT, Regitnig P (2005) Determination of layer-specific mechanical properties. Circulation 289:H2048–2058
Twal WO, Klatt SC, Harikrishnan K, Gerges E, Cooley MA, Trusk TC, Zhou B, Gabr MG, Shazly T, Lessner SM (2013) Cellularized microcarriers as adhesive building blocks for fabrication of tubular tissue constructs. Ann Biomed Eng 41:1–12
J. D. Humphrey (2002) Cardiovascular solid mechanics: cells, tissues, and organs. Springer,
Ingels N, Hansen DE, Daughters G, Stinson EB, Alderman EL, Miller DC (1989) Relation between longitudinal, circumferential, and oblique shortening and torsional deformation in the left ventricle of the transplanted human heart. Circ Res 64(5):915–927
McCULLOCH AD, Smaill BH, Hunter PJ (1987) Left ventricular epicardial deformation in isolated arrested dog heart. Am J Physiol Heart Circ Physiol 252(1):H233–H241
Pirolo J, Branham B, Creswell L, Perman W, Vannier M, Pasque M (1992) Pressure-gated acquisition of cardiac MR images. Radiology 183(2):487–492
Waldman LK, Fung Y, Covell JW (1985) Transmural myocardial deformation in the canine left ventricle. Normal in vivo three-dimensional finite strains. Circ Res 57(1):152–163
Bruck H, McNeill S, Sutton MA, Peters Iii W (1989) Digital image correlation using Newton–Raphson method of partial differential correction. Exp Mech 29(3):261–267
Chu T, Ranson W, Sutton M (1985) Applications of digital-image-correlation techniques to experimental mechanics. Exp Mech 25(3):232–244
Luo P, Chao Y, Sutton M, Peters W III (1993) Accurate measurement of three-dimensional deformations in deformable and rigid bodies using computer vision. Exp Mech 33(2):123–132
Luo P-F, Chao YJ, Sutton MA (1994) Application of stereo vision to three-dimensional deformation analyses in fracture experiments. Opt Eng 33(3):981–990
H. Schreier, J-J. Orteu, M. A. Sutton (2009) Image correlation for shape, motion and deformation measurements: basic concepts, theory and applications. Springer-Verlag US
Sutton M, Mingqi C, Peters W, Chao Y, McNeill S (1986) Application of an optimized digital correlation method to planar deformation analysis. Image Vis Comput 4(3):143–150
Sutton M, Wolters W, Peters W, Ranson W, McNeill S (1983) Determination of displacements using an improved digital correlation method. Image Vis Comput 1(3):133–139
M. A. Sutton (2008) Digital image correlation for shape and deformation measurements. In: Springer handbook of experimental solid mechanics. Springer, pp 565–600
Ning J, Wang Y, Sutton MA, Anderson K, Bischoff JE, Lessner SM, Xu S (2010) Deformation measurements and material property estimation of mouse carotid artery using a microstructure-based constitutive model. J Biomech Eng 132(12):121010
Sutton M, Ke X, Lessner S, Goldbach M, Yost M, Zhao F, Schreier H (2008) Strain field measurements on mouse carotid arteries using microscopic three–dimensional digital image correlation. J Biomed Mater Res A 84(1):178–190
Kim J, Baek S (2011) Circumferential variations of mechanical behavior of the porcine thoracic aorta during the inflation test. J Biomech 44(10):1941–1947
Rv M (1945) On Saint Venant’s principle. Bull Am Math Soc 51(8):555–562
A. Green, W. Zerna Theoretical elasticity, 1954. Clarendon Press, Oxford
T. H. Elshazly (2004) Characterization of PVA hydrogels with regards to vascular graft development
A. Rachev, T. ElShazly, D. N. Ku Constitutive formulation of the mechanical properties of synthetic hydrogels. In: ASME 2004 International Mechanical Engineering Congress and Exposition, 2004. American Society of Mechanical Engineers, pp 353–354
Gasser TC, Ogden RW, Holzapfel GA (2006) Hyperelastic modelling of arterial layers with distributed collagen fibre orientations. J R Soc Interface 3(6):15–35
Holzapfel GA, Gasser TC, Ogden RW (2000) A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elast Phys Sci Solids 61(1–3):1–48
Gleason R, Humphrey J (2004) A mixture model of arterial growth and remodeling in hypertension: altered muscle tone and tissue turnover. J Vasc Res 41(4):352–363
Holzapfel GA, Gasser TC (2007) Computational stress-deformation analysis of arterial walls including high-pressure response. Int J Cardiol 116(1):78–85
Holzapfel GA (2006) Determination of material models for arterial walls from uniaxial extension tests and histological structure. J Theor Biol 238(2):290–302
L. Li, X. Qian, S. Yan, L. Hua, H. Zhang, Z. Liu (2012) Determination of the material parameters of four-fibre family model based on uniaxial extension data of arterial walls. Computer methods in biomechanics and biomedical engineering (ahead-of-print):1–9
Li L, Qian X, Yan S, Lei J, Wang X, Zhang H, Liu Z (2013) Determination of material parameters of the two-dimensional Holzapfel–Weizsäcker type model based on uniaxial extension data of arterial walls. Comput Methods Biomech Biomed Eng 16(4):358–367
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shazly, T., Rachev, A., Lessner, S. et al. On the Uniaxial Ring Test of Tissue Engineered Constructs. Exp Mech 55, 41–51 (2015). https://doi.org/10.1007/s11340-014-9910-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11340-014-9910-2