Abstract
SPECT(single photon emission computed tomography) myocardial imaging is a diagnosis technique that images the region of interest and examines any change induced by disease using a computer after injects intravenously a radiopharmaceutical drug emitting gamma ray and the drug has dispersed evenly in the heart . Myocardial perfusion imaging, which contains functional information, is useful for non–invasive diagnosis of myocardial disease but noises caused by physical factors and low resolution give difficulty in reading the images. In order to help reading myocardial images, this study proposed a method that segments myocardial images and reconstructs the segmented region into a 3D image. To resolve difficulty in reading, we segmented the left ventricle, the region of interest, using a level set and modeled the segmented region into a 3D image.
Similar content being viewed by others
References
Malcolm Hudson, H., and Larkin, Richard S., Accelerated image reconstruction using order ed subsets of projection data. IEEE Trans. Med. Imag. 13:601–609, 1994.
Bavelaar-Croon, C. D., Pauwels, E. K., and van der Wall, E. E., Gated single-photon emission computed tomographic myocardial imaging: a new tool in clinical cardiology. Am Heart J 141:383–390, 2001.
Bacher-Stier, C., Muller, S., Pachinger, O., Strolz, S., Erler, H., Moncayo, R., Wenger, M., Donnemiller, E., and Iccabona, G., Thallium-201 gated single-photon emission tomography for the assessment of left entricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography. Eur J Nucl Med 26:1533–1540, 1999.
Wahba, F. F., Bavelaar-Croon, C. D., Baur, L. H., Zwinderman, A. H., van Roosmalen, R. P., Pauwels, E. K., and van der all, E. E., Detection of residual wall motion after sustained myocardial infrarction by gated 99Tc m-tetrofosmin SPECT: a comparison with echocardiography. Nucl Med Commun 22:175–182, 2001.
Wahba, F. F., Lamb, H. J., Bax, J. J., Dibbets-Schneider, P., Bavelaar-Croon, C. D., Zwinderman, A. H., Pauwels, E. K., and van der Wall, E. E., Assessment of regional myocardial wall motion and thickening by gated 99Tcm-tetrofosmin SPECT: a comparison with magnetic resonance imaging. Nucl Med Commun 22:663–671, 2001.
Atsma, D. E., Bavelaar-Croon, C. D., Germano, G., Dibbets-Schneider, P., van Eck-Smit, B. L., Pauwels, E. K., and van der Wall, E. E., Good correlation between gated single photon emission computed myocardial tomography and contrast ventriculography in the assess-ment of global and regional left ventricular function. Int J Card Imaging 16:447–453, 2000.
Hambye, A. S., van den Branden, F., and Vandevivere, J., Diagnostic value of Tc-99m sestamibi gated SPECT to assess viability in a patient after acute myocardial infarction. Clin Nucl Med 21:19–23, 1996.
Leitha, T., Gwechenberger, M., Pruckmayer, M., Staudenherz, A., Bailer, H., and Kronik, G., Does motion analysis in postexercise gated sestamibi SPECT reflect rest left ventricular motion even in severe coronary artery disease? Clin Nucl Med 26:694–700, 2001.
Bavelaar-Croon, C. D., Atsma, D. E., van der Wall, E. E., Dibbets-Schneider, P., Zwinderman, A. H., and Pauwels, E. K., The additive value of gated SPECT myocardial perfusion imaging in patients with known and suspected coronary artery disease. Nucl Med Commun 22:45–55, 2001.
Kroll, D., Farah, W., McKendall, G. R., Reinert, S. E., and Johnson, L. L., Prognostic value of stress-gated Tc-99m sestamibi SPECT after acute myocardial infarction. Am J Cardiol 87:381–386, 2001.
Osher, S., and Sethian, J. A., ronts propagating with curvature dependent speed: algorithms based on Hamilton-Jacobi formulations. J Comp. Phys. 79:12–49, 1988.
Zhao, H.-K., Chan, T., Merriman, B., and Osher, S., Avariational level set approach to multiphase motion. JCP 127:179–195, 1996.
Chan, T., and Vese, L., Active contours without edges. IEEE Trans Imag Proc 10:266–277, 2001.
Chan, T., and Vese, L. An active contour model without edges. n Scale-Space’9. In: Nilsen, M. et al. (Eds.), LNCS, vol. 1682, 1999.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lee, HJ., Lee, S. 3-D Surface Rendering of Myocardial SPECT Images Segmented by Level Set Technique. J Med Syst 36, 1133–1137 (2012). https://doi.org/10.1007/s10916-010-9575-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10916-010-9575-z