Abstract
The aim of this study is to compare a portable spectral domain optical coherence tomography (SD-OCT) device with a non-portable SD-OCT for the identification of anterior chamber angle parameters based on location of Schwalbe’s line (SL) and to measure their reproducibility. 99 eyes from 46 normal, healthy participants underwent imaging of the inferior iridocorneal angle with the iVue and Cirrus SD-OCT under well-controlled low-light conditions. SL-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) were measured by masked, certified graders at the Doheny Image Reading Center using customized Image J grading software. Inter- and intrainstrument, as well as inter- and intraobserver reproducibility of SL-AOD and SL-TISA measurements were evaluated with intraclass correlation coefficients (ICCs) and Bland–Altman plots with limits of agreement. The mean SL-AOD was 0.814 ± 0.315 mm with the iVue and 0.797 ± 0.294 mm with the Cirrus. The mean SL-TISA was 0.247 ± 0.112 mm2 with iVue and 0.259 ± 0.113 mm2 with Cirrus. Interinstrument correlation coefficients (r) were 0.93 (P < 0.0001), 0.92 (P < 0.0001), and 0.92 (P < 0.0001) for SL_AOD and SL_TISA, respectively. Intraclass correlation coefficient showing the degree of agreement among SL-AOD and SL-TISA was 0.923 (95 % confidence interval 0.885–0.948) and 0.921 (95 % confidence interval 0.883–0.947) for both devices. The agreement for intrainstrument (ICCs > 0.95), intragrader (ICCs > 0.93), and intergrader (ICCs > 0.96) was excellent. Excellent agreement between the two devices was also documented with Bland–Altman analysis. Both instruments provide consistent and reproducible measurements of anterior chamber angle metrics.
Similar content being viewed by others
References
World Health Organization (2014) Vision 2020 the right to sight, global initiative for the elimination of avoidable blindness; action plan 2006–2011. http://www.who.int/blindness/Vision2020_report.pdf. Accessed 13 Dec 2014
He M, Foster PJ, Johnson GJ, Khaw PT (2006) Angle-closure glaucoma in East Asian and European people. Different diseases. Eye (Lond) 20:3–12
Foster PJ, Buhrmann R, Quigley HA, Johnson GJ (2002) The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 86:238–242
Wojtkowski M, Bajraszewski T, Gorczynska I (2004) Ophthalmic imaging by spectral optical coherence tomography. Am J Ophthalmol 138:412–419
Wong HT, Lim MC, Sakata LM (2009) High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol 127:256–260
Sakata LM, Lavanya R, Friedman DS, Aung HT, Seah SK, Foster PJ, Aung T (2008) Assessment of the scleral spur in anterior segment optical coherence tomography images. Arch Ophthalmol 126:181–185
Narayanaswamy A, Sakata LM, He MG, Friedman DS, Chan YH, Lavanya R, Baskaran M, Foster PJ, Aung T (2010) Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 128:1321–1327
Memarzadeh F, Mahdaviani S, Li Y (2010) Interpretation of angle images. In: Huang D, Duker J, Lumbroso B (eds) Imaging the eye from front to back with RTVue Fourier-domain optical coherence tomography, 1st edn. SLACK, New York
Cheung CY, Zheng C, Ho CL, Tun TA, Kumar RS, Sayyad FE, Wong TY, Aung T (2011) Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark. Br J Ophthalmol 95:955–959
Qin B, Francis BA, Li Y, Tang M, Zhang X, Jiang C, Cleary C, Huang D (2013) Anterior chamber angle measurements using Schwalbe’s line with high-resolution fourier-domain optical coherence tomography. J Glaucoma 22:684–688
Tan AN, Sauren LD, de Brabander J et al (2011) Reproducibility of anterior chamber angle measurements with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci 52:2095–2099
Kim DY, Sung KR, Kang SY et al (2011) Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography. Acta Ophthalmol 89:435–441
Hu CX, Mantravadi A, Zangalli C, Ali M, Faria BM, Richman J, Wizov SS, Razenghinnejad MR, Moster MR, Katz LJ (2016) Comparing gonioscopy with Visante and Cirrus optical coherence tomography for anterior chamber angle assessment in glaucoma patients. J Glaucoma 25:177–183
Quek DT, Narayanaswamy AK, Tun TA, Htoon HM, Baskaran M, Perera SA, Aung T (2012) Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment. Invest Ophthalmol Vis Sci 53:5131–5136
Römkens HC, Beckers HJ, Frusch M, Berendschot TT, de Brabander J, Webers CA (2014) Reproducibility of anterior chamber angle analyses with the swept-source optical coherence tomography in young, healthy Caucasians. Invest Ophthalmol Vis Sci 55:3999–4004
Pan X, Marion KM, Maram J, Zhang ZY, Francis BA, Nittala MG, Sadda SR, Chopra V (2015) Reproducibility of anterior segment angle metrics measurements derived from Cirrus spectral domain optical coherence tomography. J Glaucoma 24:47–51
Marion KM, Maram J, Pan X, Dastiridou A, Zhang Z, Ho A, Francis BA, Sadda SR, Chopra V (2015) Reproducibility and agreement between 2 spectral domain optical coherence tomography devices for anterior chamber angle measurements. J Glaucoma 24:642–646
Dastiridou A, Pan X, Zhang Z, Marion KM, Francis BA, Sadda SR, Chopra V (2015) Comparison of physiologic versus pharmacologic mydriasis on anterior chamber angle measurements using spectral domain optical coherence tomography. J Ophthalmol 2015:845643
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Akil, H., Marion, K., Dastiridou, A. et al. Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT. Int Ophthalmol 37, 31–37 (2017). https://doi.org/10.1007/s10792-016-0223-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-016-0223-6