Development of the High-Temperature Dew-Point Generator Over the Past 15 Years

  • TEMPMEKO 2016
  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from \(70\,{^{\circ }}\hbox {C}\) to \(95\,{^{\circ }}\hbox {C}\) dew-point temperature, and the last modification allows an uncertainty of \(0.048\,{^{\circ }}\hbox {C}\) (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to \(95\,{^{\circ }}\hbox {C}\). In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within \(0.01\,{^{\circ }}\hbox {C}\) with PTB and NPL.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. M.J. de Groot, Papers and Abstracts from the Third International Symposium on Humidity and Moisture, vol. 1 (NPL, London, 1998), pp. 53–61

    Google Scholar 

  2. J. Nielsen, M.J. de Groot, Metrologia 41, 167–172 (2004)

    Article  ADS  Google Scholar 

  3. S. Bell, M. Stevens, H. Abe, R. Benyon, R. Bosma, V. Fernicola, M. Heinonen, P. Huang, H. Kitano, Z. Li, J. Nielsen, N. Ochi, O.A. Podmurnaya, G. Scace, D. Smorgon, T. Vicente, A.F. Vinge, L. Wang, H. Yi, Metrologia 52, 03005 (2015)

  4. M. Heinonen. Metrologia 47, 329–336 (2010)

  5. R. Bosma, A. Peruzzi, Int. J. Thermophys. 33, 1511–1519 (2012)

    Article  ADS  Google Scholar 

  6. R. Mokhutshoane, J. Nielsen, C. Barendregt, M.J. de Groot, in Papers from the 4th International Symposium on Humidity and Moisture (Center for Measurement Standards, ITRI, National Measurement Laboratory, R.O.C., 2002). pp. 493–499

  7. R. Bosma, A. Peruzzi, Int. J. Thermophys. 35, 738–747 (2014)

    Article  ADS  Google Scholar 

Download references

Acknowledgements

This work was funded by the Ministry of Economic Affairs, The Netherlands.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Bosma.

Additional information

Selected Papers of the 13th International Symposium on Temperature, Humidity, Moisture and Thermal Measurements in Industry and Science.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bosma, R., Nielsen, J. & Peruzzi, A. Development of the High-Temperature Dew-Point Generator Over the Past 15 Years. Int J Thermophys 38, 161 (2017). https://doi.org/10.1007/s10765-017-2291-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10765-017-2291-x

Keywords

Navigation