Skip to main content
Log in

A portable, integrated analyzer for microfluidic – based molecular analysis

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

A portable, fully automated analyzer that provides actuation and flow control to a disposable, self-contained, microfluidic cassette (“chip”) for point-of-care, molecular testing is described. The analyzer provides mechanical actuation to compress pouches that pump liquids in the cassette, to open and close diaphragm valves for flow control, and to induce vibrations that enhance stirring. The analyzer also provides thermal actuation for the temperature cycling needed for polymerase chain reaction (PCR) amplification of nucleic acids and for various drying processes. To improve the temperature uniformity of the PCR chamber, the system utilizes a double-sided heating/cooling scheme with a custom feedforward, variable, structural proportional-integral-derivative (FVSPID) controller. The analyzer includes a programmable central processing unit that directs the sequence and timing of the various operations and that is interfaced with a computer. The disposable cassette receives a sample, and it carries out cell lysis, nucleic acid isolation, concentration, and purification, thermal cycling, and either real time or lateral flow (LF) based detection. The system’s operation was demonstrated by processing saliva samples spiked with B. cereus cells. The amplicons were detected with a lateral flow assay using upconverting phosphor reporter particles. This system is particularly suited for use in regions lacking centralized laboratory facilities and skilled personnel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • R.H. Birkhahn, E. Haines, W. Wen, L. Reddy, W.M. Briggs, P.A. Datillo, Estimating the clinical impact of bringing a multimarker cardiac panel to the bedside in the ED. Am. J. Emerg. Med. 29, 304 (2011)

    Article  Google Scholar 

  • R. Boom, C.J. Sol, M.M. Salimans, C.L. Jansen, P.M. Wertheim-van Dillen, J.V.D. Noordaa, Rapid and simple method for purification of nucleic acids. J. Clin. Microbiol. 28, 495 (1990)

    Google Scholar 

  • Z. Chen, M.G. Mauk, J. Wang, W.R. Abrams, P.L.A.M. Corstjens, R.S. Niedbala, D. Malamud, H.H. Bau, A microfluidic system for saliva-based detection of infectious diseases. Ann. NY Acad. Sci. 1098, 429 (2007)

    Article  Google Scholar 

  • D. Chen, M.G. Mauk, X. Qiu, C. Liu, J. Kim, S. Ramprasad, S. Ongagna, W.R. Abrams, D. Malamud, P.L.A.M. Corstjens, H.H. Bau, An integrated microfluidic cassette for isolation, amplification, and detection of nucleic acids. Biomed. Microdevices 12, 705 (2010)

    Article  Google Scholar 

  • C.J. Easley, J.M. Karlinsey, J.M. Bienvenue, L.A. Legendre, M.G. Roper, S.H. Feldman, M.A. Hughes, E.L. Hewlett, T.J. Merkel, J.P. Ferrance, J.P. Landers, A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability. PNAS 103, 19272 (2006)

    Article  Google Scholar 

  • J. Kim, D. Byun, M.G. Mauk, H.H. Bau, A disposable, self-contained PCR chip. Lab Chip 9, 606 (2009)

    Article  Google Scholar 

  • E.T. Lagally, J.R. Scherer, R.G. Blazerj, N.M. Toriello, B.A. Diep, M. Ramchandani, G.F. Sensabaugh, L.W. Riley, R.A. Mathies, Integrated portable genetic analysis microsystem for pathogen/infectious disease detection. Anal. Chem. 76, 3162 (2004)

    Article  Google Scholar 

  • E. Lee-Lewandrowski, K. Lewandrowski, Perspectives on cost and outcomes for point-of-care testing. Clin. Lab. Med. 29, 479 (2009)

    Article  Google Scholar 

  • R.H. Liu, J. Yang, R. Lenigk, J. Bonanno, P. Grodzinski, Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction, amplification, and DNA microarray detection. Anal. Chem. 76, 1824 (2004)

    Article  Google Scholar 

  • J.S. Marcus, W.F. Anderson, S.R. Quake, Parallel picoliter RT-PCR assays using microfluidics. Anal. Chem. 78, 956 (2006)

    Article  Google Scholar 

  • K. Pothier, M. Kirtland, S. Gupta, Has point-of-care come of age? POC 9, 147 (2010)

    Google Scholar 

  • X. Qiu, J. Yuan, Z. Wang, Chin. J. Chem. Eng. 14, 200 (2006)

    Article  Google Scholar 

  • X. Qiu, J.A. Thompson, Z. Chen, C. Liu, D. Chen, S. Ramprasad, M.G. Mauk, S. Ongagna, C. Barber, W.R. Abrams, D. Malamud, P.L.A.M. Corstjens, H.H. Bau, Finger-actuated, self-contained immunoassay cassettes. Biomed. Microdevices 11, 1175 (2009)

    Article  Google Scholar 

  • X. Qiu, M.G. Mauk, D. Chen, C. Liu, H.H. Bau, A large volume, portable, real-time PCR reactor. Lab Chip 10, 3170 (2010)

    Article  Google Scholar 

  • X. Qiu, C. Liu, M.G. Mauk, R.W. Hart, D. Chen, J. Qiu, T. Kientz, J. Fiene, H.H. Bau, A portable analyzer for pouch-actuated, immunoassay cassettes. Sens. Actuators B. submitted (2011)

  • F.V.D. Rijke, H. Zijlmans, S. Li, T. Vail, A.K. Raap, R.S. Niedbala, H.J. Tanke, Up-converting phosphor reporters for nucleic acid microarrays. Nat. Biotech. 19, 273 (2001)

    Article  Google Scholar 

  • M.G. Roper, C.J. Easley, J.P. Landers, Advances in polymerase chain reaction on microfluidic chips. Anal. Chem. 77, 3887 (2005)

    Article  Google Scholar 

  • J. Wang, Z. Chen, P.L.A.M. Corstjens, M.G. Mauk, H.H. Bau, A disposable microfluidic cassette for DNA amplification and detection. Lab Chip 6, 46 (2006)

    Article  Google Scholar 

  • C. Zhang, J. Xu, W. Ma, W. Zheng, PCR microfluidic devices for DNA amplification. Biotech. Advan. 24, 243 (2006)

    Article  Google Scholar 

Download references

Acknowledgments

The work was supported by NIH/NIDCR Grant U01DE017855.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haim H. Bau.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Qiu, X., Chen, D., Liu, C. et al. A portable, integrated analyzer for microfluidic – based molecular analysis. Biomed Microdevices 13, 809–817 (2011). https://doi.org/10.1007/s10544-011-9551-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-011-9551-5

Keywords

Navigation