Skip to main content
Log in

The effects of L’Aquila earthquake on the St. Gemma church in Goriano Sicoli: part I—damage survey and kinematic analysis

  • Original Research Paper
  • Published:
Bulletin of Earthquake Engineering Aims and scope Submit manuscript

Abstract

The paper deals with the structural response of the St. Gemma church in the small historical centre of Goriano Sicoli, which was stricken by the 2009 L’Aquila earthquake. This church is a typical example of Abruzzi baroque architecture and is representative of a large population of similar samples belonging to a wide territorial area. A detailed survey of the damages provoked by the earthquake on both the whole church and its main macro-elements is presented. Then, the observed mechanisms are interpreted by the implementation of both linear and non linear kinematic analyses. The comparison between the obtained results and the occurred seismic demand allows to justify the revealed state of damage and to prove the reliability of the proposed evaluation procedure. In the companion paper, the main outcomes of a FEM response spectrum analysis are presented in order to investigate the structural vulnerability of the church through a detailed analysis of the local stress distribution.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18

Similar content being viewed by others

References

  • Criber E, Brando G, De Matteis G (2011) Structural individuation of damages occurred on St. Gemma church in Goriano Sicoli during the 2009 L’Aquila earthquake. Appl Mech Mater 82:816–821

    Article  Google Scholar 

  • Circolare 2 febbraio (2009) n. 617—Istruzioni per l’applicazione delle “Nuove norme tecniche per le costruzioni” di cui al D.M. 14 gennaio 2008. Gazzetta Ufficiale n. 47 del 26 febbraio 2009—Suppl. Ordinario n. 27

  • D’Ayala DF (2005) Force and displacement based vulnerability assessment for traditional buildings. Bull Earthq Eng 3(3):235–265

    Article  Google Scholar 

  • D’Ayala DF, Paganoni S (2011) Assessment and analysis of damage in L’Aquila historic city centre after 6th April 2009. Bull Earthq Eng 9(1):81–104

    Article  Google Scholar 

  • De Matteis G, Criber E, Brando G (2015) Damage probability matrices for three naves masonry churches in abruzzi based on the experience of 2009 l’aquila earthquake. Int J Archit Herit. ISSN 1558-3058

  • Decreto Ministeriale 14/01/2008 (NTC 2008). Norme Tecniche per le Costruzioni (Italian)

  • Doherty K, Griffith MC, Lam N, Wilson J (2002) Displacement-based seismic analysis for out-of-plane bending of unreinforced masonry walls. Earthq Eng Struct Dynam 31(4):833–850

    Article  Google Scholar 

  • Galli P, Camassi R (2009) Rapporto sugli effetti del terremoto aquilano del 6 Aprile. National Department of Civil Protection

  • Griffith MC, Magenes G, Melis G, Picchi L (2003) Evaluation of out-of-plane stability of unreinforced masonry walls subjected to seismic excitation. J Earthq Eng 7:141–169

    Google Scholar 

  • Grunthal G (1998) European Macroseismic Scale. In: Cahiers du Centre Europ. de Géodyn. et de Séismologie, vol 15

  • Gruppo di Lavoro MS–AQ (2010) Microzonazione sismica per la ricostruzione dell’area aquilana. Regione Abruzzo—Dipartimento della Protezione Civile, L’Aquila, 3 vol. e Cd-rom

  • Lagomarsino S (2004) Seismic vulnerability of ancient churches: I. Damage assessment and emergency planning. Earthq Spectra 20(2):377–394. doi:10.1193/1

    Article  Google Scholar 

  • Lagomarsino S (2012) Damage assessment of churches after L’Aquila earthquake (2009). Bull Earthq Eng 10(1):73–92

    Article  Google Scholar 

  • Marganelli E, d’Oca A, Ceccaroni E, Giannantonio R, Di Giannantonio P, Morini P, De Santis G (2009) Goriano Sicoli. Storia e arte nel paese di Santa Gemma, Amaltea Editions

  • Ministry of Heritage and Cultural Activities (2010) Circular n.26, Italian Code for protection of cultural heritage. Linee Guida per la valutazione e la riduzione del rischio Sismico del patrimonio culturale con riferimento alle norme tecniche per le costruzioni. Prot 10953 of 02/12/2010

  • National Civil Protection (2009) Abruzzi Region Civil Protection, Geology Science Department, Roma Tre University. Homogeneous microzone map

  • National Fire Corp. Abruzzo Sisma (2009) Interventi di messa in sicurezza sui beni monumentali. http://www.vigilfuoco.it/aspx/home.aspx

  • Ordinanza PCM (2003) n. 3274 (Suppl. Ord. alla G.U. 8.5.2003, n. 105)

  • Sabetta F, Pugliese A (1987) Attenuation of peak horizontal acceleration and velocity from Italian strong-motion records. Bull Seismol Soc Am 77:1491–1513

    Google Scholar 

Download references

Acknowledgments

This study has been developed in the framing of the agreement between the University of Chieti-Pescara and the Goriano Sicoli Municipality for the drafting of the post L’Aquila Earthquake Reconstruction Plan. Some of the activities have been included within the research project AVVERSA, supported by the Abruzzi Region and the University of Chieti-Pescara (POR 2007-2013-Azione 4).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gianfranco De Matteis.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Criber, E., Brando, G. & De Matteis, G. The effects of L’Aquila earthquake on the St. Gemma church in Goriano Sicoli: part I—damage survey and kinematic analysis. Bull Earthquake Eng 13, 3713–3732 (2015). https://doi.org/10.1007/s10518-015-9792-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10518-015-9792-4

Keywords

Navigation