Abstract
A number of in vivo, in vitro and numerical studies have considered flow field characteristics and micro-particle deposition in the oral airway extending from the mouth through the larynx. These studies have highlighted the effects of flow rates, turbulence and particle characteristics on deposition values in realistic and simplified geometries. However, the effect of geometry simplifications on regional and local deposition patterns remains largely un-quantified for the oral airway and throughout the respiratory tract. The objective of this study is to assess the effects of geometry simplifications on regionally averaged and local micro-aerosol deposition characteristics in models of the extrathoracic oral airway. To achieve this objective, a realistic model of the oral airway has been constructed based on CT scans of a healthy adult in conjunction with measurements reported in the literature. Three other geometries with descending degrees of physical realism were constructed based on successive geometric simplifications of the realistic model. A validated low Reynolds number (LRN) k–ω turbulence model was employed to simulate laminar, transitional and fully turbulent flow regimes for 1–31 μm particles. Geometric simplifications were found to have a significant effect on aerosol dynamics, hot spot formations and cellular-level deposition values in the extrathoracic airway models considered. For all models, regional deposition efficiency results were found to be approximately within one standard deviation of available experimental data when plotted as a function of Stokes number. The realistic geometry provided the best predictions of regional deposition in comparison to experimental data as a function of particle diameter. Considering localized deposition, maximum deposition enhancement factors, which represent the ratio of local to total deposition, were one to two orders of magnitude higher for the realistic model. Geometric factors that significantly contributed to enhanced particle localization in the realistic model include a triangular-shaped glottis and a dorsal-sloped trachea. Therefore, highly realistic models of the oral airway geometry may be necessary to evaluate localized deposition patterns and hot spot formations, which are critical for accurately predicting cellular-level dose.
Similar content being viewed by others
References
Balashazy I., W. Hofmann. 1993 Particle deposition in airway bifurcations-I. Inspriatory flow. J. Aerosol Sci. 24:745–772
Balashazy I., W. Hofmann. 1993 Particle deposition in airway bifurcations-II. Experiatory flow. J Aerosol Sci 24:773–786
Balashazy I., W. Hofmann, T. Heistracher. 1999 Computation of local enhancement factors for the quantification of particle deposition patterns in airway bifurcations. J. Aerosol Sci. 30:185–203
Balashazy I., W. Hofmann, T. Heistracher. 2003 Local particle deposition patterns may play a key role in the development of lung cancer. Trans. Physiol. 94:1719–1725
Brancatisano T., P. W. Collett, L. A. Engel. 1983 Respiratory movements of the vocal cords. J. Appl. Physiol. 54(5):1269–1276
Chan T. L., M. Lippmann. 1980 Experimental measurements and emperical modeling of the regional deposition of inhaled particles in humans. Am. Ind. Hyg. Assoc. J. 41:399–409
Cheng K. H., Y. S. Cheng, H. C. Yeh, D. L. Swift. 1997 Measurements of airway dimensions and calculation of mass transfer characteristics of the human oral passage. J. Biomech. Eng. 119:476–482
Cheng Y. S. 2003 Aerosol deposition in the extrathoracic region. Aerosol Sci. Tech. 37:659–671
Cheng Y. S., Y. Zhou, B. T. Chen. 1999 Particle deposition in a cast of human oral airways. Aerosol Sci. Tech. 31:286–300
Corcoran T. E., N Chigier. 2000 Characterization of the laryngeal jet using phase Doppler interferometry. J. Aerosol Med. 13(2):125–137
Crowe C. T., T. R. Troutt, J. N. Chung. 1996 Numerical models for two-phase turbulent flows. Ann. Rev. Fluid Mech. 28:11–43
DeHaan W. H., W. H. Finlay. 2004 Predicting extrathoracic deposition from dry powder inhalers. J. Aerosol Sci. 35:309–331
Ehtezazi T., M. A. Horsfield, P. W. Barry, C O’Callaghan. 2004 Dynamic change of the upper airway during inhalation via aerosol delivery devices. J. Aerosol Med. 14(4):325–332
Finlay W. H. The Mechanics of Inhaled Pharmaceutical Aerosols. Academic Press, San Diego, 2001
Gemci T., T. E. Corcoran, N. Chigier. 2002 A numerical and experimental study of spray dynamics in a simple thrat model. Aerosol Sci. Tech. 36:18–38
Ghalichi F., X. Deng, A. D. Champlain, Y. Douville, M. King, R. Guidoin. 1998 Low Reynolds number turbulence modeling of blood flow in arterial stenoses. Biorheology 35(4&5):281–294
Goo J., C. S. Kim. 2003 Theoretical analysis of particle deposition in human lungs considering stochastic variations of airway morphology. J. Aerosol Sci. 34(5):585–602
Grgic B., W. H. Finlay, P. K. P. Burnell, A. F. Heenan. 2004 In vitro intersubject and intrasubject deposition measurements in realistic mouth-throat geometries. J. Aerosol Sci. 35(8):1025–1040
Grgic B., W. H. Finlay, A. F. Heenan. 2004 Regional aerosol deposition and flow measurements in an idealized mouth and throat. J. Aerosol Sci. 35(1):21–32
Heenan A. F., W. H. Finlay, B. Grgic, A. Pollard, P. K. P. Burnell. 2004 An investigation of the relationship between the flow field and regional deposition in realistic extra-thoracic airways. J. Aerosol Sci. 35(8):1013–1023
Heyder J., G. Rudolf. 1984 Mathematical-models of particle deposition in the human respiratory-tract. J. Aerosol Sci. 15(6):697–707
Hofmann W., B. Asgharian, R. Winkler-Heil. 2002 Modeling intersubject variability of particle deposition in human lungs. J. Aerosol Sci. 33(2):219–235
Kim C. S., D. Fisher. 1999 Deposition characteristics of aerosol particles in sequentially bifurcating airway models. Aerosol Sci. Technol. 31:198–220
Kleinstreuer C., Z. Zhang. 2003 Laminar-to-turbulent fluid-particle flows in a human airway model. Int. J. Multiphase Flow 29(2):271–289
Li W. I., M. Perzl, J. Heyder, R. Langer, J. D. Brain, K. H. Englmeier, R. W. Niven, D. A. Edwards. 1996 Aerodynamics and aerosol particle deaggregation phenomena in model oral-pharyngeal cavities. J. Aerosol Sci. 27(8):1269–1286
Lin T. C., P. N. Breysse, B. L. Laube, D. L. Swift. 2001 Mouthpiece diameter affects deposition efficiency in cast models of the human oral airways. J. Aerosol Med. 14(3):335–341
Longest P. W., C. Kleinstreuer, J. R. Buchanan. 2004 Efficient computation of micro-particle dynamics including wall effects. Comput. Fluids 33(4):577–601
Longest, P. W. and M. J. Oldham. Mutual enhancements of CFD modeling and experimental data: A case study of one micrometer particle deposition in a branching airway model. Inhalation Toxicol. 18(10):761−772, 2006
Longest, P. W. and S. Vinchurkar. Effects of mesh style and grid convergence on particle deposition in bifurcating airway models with comparisons to experimental data. Med. Eng. Phys. 29:350−366, 2007
Longest, P. W. and S. Vinchurkar. Validating CFD predictions of respiratory aerosol deposition: Effects of upstream transition and turbulence. J. Biomech. 40:305−316, 2007
Longest, P. W., S. Vinchurkar, and T. B. Martonen. Transport and deposition of respiratory aerosols in models of childhood asthma. J. Aerosol Sci. 37(10):1234−1257, 2006
Loth E. 2000 Numerical approaches for motion of dispersed particles droplets and bubbles. Progr. Energy Combust. Sci. 26:161–223
Lumb A. B., Nunn’s Applied Respiratory Physiology. Butterworth Heinemann, Oxford, 2000
Martonen, T. B. Surrogate experimental models for studying particle deposition in the human respiratory tract: An overview. In: S. D. Lee, editor, Aerosols. Lewis Publishers, Chesea, Michigan, 1986
Martonen T. B. 1993 Mathematical model for the selective deposition of inhaled pharmaceuticals. J. Pharm. Sci. 82(12):1191–1199
Martonen T. B., X. Guan, R. M. Schreck. 2001 Fluid dynamics in airway bifurcations: I. Primary flows. Inhalation Toxicol. 13(4):261–279
Martonen T. B., C. J. Musante, R. A. Segal, J. D. Schroeter, D. Hwang, M. A. Dolovich, R. Burton, R. M. Spencer, J. S. Fleming. 2000 Lung models: Strengths and limitations. Resp. Care 45(6):712–736
Martonen T. B., J. D. Schroeter. 2003 Risk assessment dosimetry model for inhaled particulate matter: I. Human subjects. Toxicol. Lett. 138(1–2):119–132
Matida E. A., W. H. Finlay, L. B. Grgic. 2004 Improved numerical simulation of aerosol deposition in an idealized mouth-throat. J. Aerosol Sci. 35(1):1–19
McRobbie D. W., S. E. Pritchard. 2005 Studies of the human oropharyngeal airspaces using magnetic resonance imaging. III. The effects of device resistance with forced maneuver and tidal breathing on upper airway geometry. J. Aerosol Med.-Dep. Clear. Effects Lung 18(3):325–336
McRobbie D. W., S. Pritchard, R. A. Quest. 2003 Studies of the human oropharyngeal airspaces using magnetic resonance imaging. 1. Validation of a three-dimensional MRI method for producing ex vivo virtual and physical casts of the oropharyngeal airways during inspiration. J. Aerosol Med.-Dep. Clear. Effects Lung 16(4):401–415
Morsi S. A., A. J. Alexander. 1972 An investigation of particle trajectories in two-phase flow systems. J. Fluid Mech. 55(2):193–208
Nowak N., P. P. Kakade, A. V. Annapragada. 2003 Computational fluid dynamics simulation of airflow and aerosol deposition in human lungs. Ann. Biomed. Eng. 31:374–390
Oho K., R. Amemiya. Practical Fiberoptic Bronscopy. Igaku-Shoin, Tokyo, 1980
Oldham M. J., R. F. Phalen, T. Heistracher. 2000 Computational fluid dynamic predictions and experimental results for particle deposition in an airway model. Aerosol Sci. Technol. 32(1):61–71
Pritchard S. E., D. W. McRobbie. 2004 Studies of the human oropharyngeal airspaces using magnetic resonance imaging. II. The use of three-dimensional gated MRI to determine the influence of mouthpiece diameter and resistance of inhalation devices on the oropharyngeal airspace geometry. J. Aerosol Med.-Dep. Clear. Effects Lung 17(4):310–324
Rauch, R. D., J. T. Batira, and N. T. Y. Yang. Spatial adaption procedures on unstructured meshes for accurate unsteady aerodynamic flow computations. Technical Report AIAA-91-1106
Renotte C., V. Bouffioux, F. Wilquem. 2000 Numerical 3D analysis of oscillatory flow in the time-varying laryngeal channel. J. Biomech. 33(12):1637–1644
Roache P. J. Verification and Validation in Computational Science and Engineering. Hermosa Publisher, Albuquerque, NM, 1998
Rodenstein D. O., G. Dooms, Y. Thomas, G. Liistro, D. C. Stanescu, C. Culee, G. Auberttulkens. 1990 Pharyngeal shape and dimensions in healthy-subjects, snorers, and patients with obstructive sleep-apnea. Thorax 45(10):722–727
Rudolf G. 1984 A mathematical-model for the deposition of aerosol-particles in the human respiratory-tract. J. Aerosol Sci. 15(3):195–199
Schlesinger R. B., M. Lippmann. 1978 Selective particle deposition and bronchogenic carcinoma. Environ. Res. 15:424–431
Stahlhofen W., J. Gebhart, J. Heyder, G Scheuch. 1983 New regional deposition data of the human respiratory tract. J. Aerosol Sci. 14:186–188
Stahlhofen W., G. Rudolf, A. C. James. 1989 Intercomparison of experimental regional aerosol deposition data. J. Aerosol Med. 2(3):285–308
Stapleton K. W., E. Guentsch, M. K. Hoskinson, W. H. Finlay. 2000 On the suitability of k-epsilon turbulence modeling for aerosol deposition in the mouth and throat: A comparison with experiment. J. Aerosol Sci. 31(6):739–749
Wilcox D. C. Turbulence Modeling for CFD, 2. DCW Industries, Inc., California, 1998
Yu C. P., C. K. Diu, T. T. Soong. 1981 Statistical analysis of aerosol deposition in nose and mouth. Am. Ind. Hyg. Assoc. J. 42:726–733
Zhang Y., W. H. Finlay, E. A. Matida. 2004 Particle deposition measurements and numerical simulation in a highly idealized mouth-throat. J. Aerosol Sci. 35(7):789
Zhang Z., C. Kleinstreuer. 2001 Effect of particle inlet distributions on deposition in a triple bifurcation lung airway model. J. Aerosol Med.-Dep. Clear. Effects Lung 14(1):13–29
Zhang Z., C. Kleinstreuer. 2002 Transient airflow structures and particle transport in a sequentially branching lung airway model. Phys. Fluids 14(2):862–880
Zhang Z., C. Kleinstreuer. 2003 Low-Reynolds-number turbulent flows in locally constricted conduits: A comparison study. Aiaa J. 41(5):831–840
Zhang Z., C. Kleinstreuer. 2003 Species heat and mass transfer in a human upper airway model. Int. J. Heat Mass Trans. 46(25):4755–4768
Zhang Z., C. Kleinstreuer. 2004 Airflow structures and nano-particle deposition in a human upper airway model. J. Comput. Phys. 198(1):178–210
Zhang Z., C. Kleinstreuer, J. F. Donohue, C. S. Kim. 2005 Comparison of micro- and nano-size particle depositions in a human upper airway model. J. Aerosol Sci. 36(2):211–233
Zhang Z., C. Kleinstreuer, C. S. Kim. 2001 Flow structure and particle transport in a triple bifurcation airway model. J. Fluids Eng.-Trans. ASME 123(2):320–330
Zhang Z., C. Kleinstreuer, C. S. Kim. 2002 Cyclic micron-size particle inhalation and deposition in a triple bifurcation lung airway model. J. Aerosol Sci. 33(2):257–281
Zhang Z., C. Kleinstreuer, C. S. Kim. 2002 Micro-particle transport and deposition in a human oral airway model. J. Aerosol Sci. 33(12):1635–1652
Zhang Z., C. Kleinstreuer, C. S. Kim. 2006 Water vapor transport and its effects on the deposition of hygroscopic droplets in a human upper airway model. Aerosol Sci. Technol. 40:52–67
Zhang Z., T. B. Martonen. 1997 Deposition of ultrafine aerosols in human tracheobronchial airways. Inhalation Toxicol. 9:99–110
Zhao Y., B. B. Lieber. 1994 Steady inspiratory flow in a model symmetrical bifurcation. J. Biomech. Eng. 116(4):488–496
Zhou Y., Y. S. Cheng. 2005 Particle deposition in a cast of human tracheobrochial airways. Aerosol Sci. Technol. 39:492–500
Acknowledgments
This work was sponsored in part by Philip Morris USA under grant 06-i077-01 (Dr. Mohammad R. Hajaligol, Program Manager). The use of CT data provided by Dr. Karen A. Kurdziel in the VCU Department of Radiology and Molecular Imaging Center under IRB approval 06263 is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xi, J., Longest, P.W. Transport and Deposition of Micro-Aerosols in Realistic and Simplified Models of the Oral Airway. Ann Biomed Eng 35, 560–581 (2007). https://doi.org/10.1007/s10439-006-9245-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-006-9245-y