Skip to main content
Log in

Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect

  • Research Paper
  • Published:
Microfluidics and Nanofluidics Aims and scope Submit manuscript

Abstract

Point-of-care (POC) diagnostics is one of the most important applications for microfluidic research. However, the development of microfluidic POC devices needs to overcome great obstacles to reach market. One challenge is to find a chip-scale pumping strategy that is of low cost, small size, and light weight. Because of their simple implementation, electrokinetic techniques have been extensively investigated as a promising candidate for realizing disposable pumps, with the majority of research effort focusing on direct current and alternating current (AC) electroosmosis. As POC applications often need to handle conductive biofluids with medium to high salt content, AC electrothermal (ACET) effect has been investigated recently for pumping of biofluids, albeit with less than desirable pumping performance. In order to achieve effective on-chip ACET micropumps, this paper presents one of the first efforts in optimizing ACET micropump design utilizing planar interdigitated electrodes. The effects of electrode dimensions on pumping rate were numerically studied using COMSOL Multiphysics and MATLAB, and an optimal ratio of electrode geometry was found for various pumping scenarios. The optimal geometry ratio was tested to be valid over a wide range of electrode characteristic lengths, AC signals, and fluid ionic strengths. Experimental validation of the simulation results was also conducted, and higher flow velocities over prior reports were consistently demonstrated by optimized electrode arrays.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  • Adamiak K, Mizuno A, Nakano M (2009) Electrohydrodynamic flow in optoelectrostatic micropump: experiment versus numerical simulation. IEEE Trans Ind Appl 45(2):615–622

    Article  Google Scholar 

  • Castellanos A, Ramos A, Gonzalez A, Green NG, Morgan H (2003) Electro-hydrodynamics and dielectrophoresis in microsystems: scaling laws. J Phys D Appl Phys 36:2584–2597

    Article  Google Scholar 

  • Chen DF, Du H (2006) Simulation studies on electrothermal fluid flow induced in a dielectrophoretic microelectrode system. J Micromech Microeng 16:2411–2419

    Article  Google Scholar 

  • Chung AJ, Kim D, Erickson D (2008) Electrokinetic microfluidic devices for rapid, low power drug delivery in autonomous microsystems. Lab Chip 8:330–338

    Article  Google Scholar 

  • Du E, Manoochehri S (2008) Enhanced ac electrothermal fluidic pumping in microgrooved channels. J Appl Phys 104(6):064902

    Article  Google Scholar 

  • Green NG, Ramos A, Gonzaleza A, Castellanosa A, Morgan H (2001) Electrothermally induced fluid flow on microelectrodes. J Electrostat 53:71–87

    Article  Google Scholar 

  • Hong FJ, Cao J, Cheng P (2011) A parametric study of AC electrothermal flow in microchannels with asymmetrical interdigitated electrodes. Int Commun Heat Mass Transf 38:275–279

    Article  Google Scholar 

  • Islam N, Lian M, Wu J (2007) Enhancing cantilever capability with integrated AC electrokinetic trapping mechanism. J Microfluid Nanofluid 3(3):369–375

    Article  Google Scholar 

  • Li D (2004) Electrokinetics in microfluidics. Elsevier, Amsterdam

    Google Scholar 

  • Lian M, Wu J (2009a) Microfluidic flow reversal at low frequency by AC electrothermal effect. Microfluid Nanofluid 7(6):757–765

    Article  Google Scholar 

  • Lian M, Wu J (2009b) Ultrafast micropumping by biased alternating current electrokinetics. Appl Phys Lett 94:064101

    Article  Google Scholar 

  • Lian M, Islam N, Wu J (2007) AC electrothermal manipulation of conductive fluids and particles for lab-chip applications. IET Nanobiotechnol 1(3):36–43

    Article  Google Scholar 

  • Lide DR (ed) (2011–2012) CRC handbook of chemistry and physics, 92nd edn. CRC Press, London, pp 5–74 and 6–187

  • Liu X, Yang K, Wadhwa A, Eda S, Li S, Wu J (2011) Development of an AC electrokinetics-based immunoassay system for on-site serodiagnosis of infectious diseases. Sens Actuators A Phys 171:406–413

    Article  Google Scholar 

  • Oh J, Hart R, Capurro J, Noh H (2008) Comprehensive analysis of particle motion under non-uniform AC electric fields in a microchannel. Lab Chip 9(1):62–78

    Article  Google Scholar 

  • Olesen LH, Bruus H, Ajdari A (2006) AC electrokinetic micropumps: the effect of geometrical confinement, Faradaic current injection, and nonlinear surface capacitance. Phys Rev E 73:056313

    Google Scholar 

  • Ramos A, Morgan H, Green NG, Castellanos A (1998) AC electrokinetics: a review of forces in microelectrode structures. J Phys D Phys 31:2338–2353

    Article  Google Scholar 

  • Ramos A, Gonzalez A, Castellanos A, Green NG, Morgan H (2003) Pumping of liquids with ac voltages applied to asymmetric pairs of microelectrodes. Phys Rev E 67:056302

    Google Scholar 

  • Stratton JA (1941) Electromagnetic theory. McGraw-Hill, New York

    MATH  Google Scholar 

  • Studer V, Pépin A, Chen Y, Ajdari A (2004) An integrated AC electrokinetic pump in a microfluidic loop for fast tunable flow control. Analyst 129:944–949

    Article  Google Scholar 

  • Urbanski JP, Thorsen T, Levitan JA, Bazant MZ (2006) Fast AC electro-osmotic pumps with non-planar electrodes. Appl Phys Lett 89:143508

    Google Scholar 

  • Wood J, Zhang B, Tomkins M, Docoslis A (2007) Numerical investigation of AC electrokinetic virus trapping inside high ionic strength media. Microfluid Nanofluid 3(5):547–560

    Article  Google Scholar 

  • Wu J (2006) Electrokinetic microfluidics for on-chip bioparticle processing. IEEE Trans Nanotech 5(2):84–89

    Article  Google Scholar 

  • Wu J (2008a) Interactions of electrical fields with fluids: laboratory-on-a-chip applications. IET Nanobiotechnol 2(1):14–27

    Article  Google Scholar 

  • Wu J (2008) AC electroosmotic micropump by asymmetric electrode polarization. J Appl Phys 103:024907

    Google Scholar 

  • Wu J, Lian M, Yang K (2007) Micropumping of biofluids by AC electrothermal effects. Appl Phys Lett 90:234103

    Google Scholar 

  • Yang K, Wu J (2010) Numerical study of in situ pre-concentration for rapid and sensitive nanoparticle detection. Biomicrofluidics 4:034106

    Google Scholar 

  • Yuan Q, Wu J (2013) Thermally biased AC electrokinetic pumping effect for lab-on-a-chip based delivery of biofluids. Biomed Microdev 15(1):125–133

    Article  MathSciNet  Google Scholar 

  • Zhang R, Dalton C, Graha A (2010) Jullien, two-phase AC electrothermal fluidic pumping in a coplanar asymmetric electrode array. Microfluid Nanofluid 10(3):521–529

    Article  Google Scholar 

Download references

Acknowledgments

This study was supported by the US National Science Foundation under Grant No. ECS-0448896. Microfabrication of this research was conducted at the Center for Nanophase Materials Sciences, which is sponsored at Oak Ridge National Laboratory by the Scientific User Facilities Division, US Department of Energy.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jie Wu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yuan, Q., Yang, K. & Wu, J. Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect. Microfluid Nanofluid 16, 167–178 (2014). https://doi.org/10.1007/s10404-013-1231-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10404-013-1231-8

Keywords

Navigation