Skip to main content

Advertisement

Log in

Transperineal versus hydrogen peroxide-enhanced endoanal ultrasonography in never operated and recurrent cryptogenic fistula-in-ano: a pilot study

  • ORIGINAL ARTICLE
  • Published:
Techniques in Coloproctology Aims and scope Submit manuscript

An Erratum to this article was published on 01 March 2009

Abstract

Background

Accurate delineation of anal fistula anatomy in recurrent cases will assist in surgical fistula eradication whilst preserving continence. Recently, transperineal ultrasonography (TPUS) has been used in perirectal inflammation where there may be advantage over endoanal ultrasonography (EAUS) in complex fistulae- in-ano which lie outside the focal range of the endoanal probe. We assessed the sensitivity of these two imaging modalities to characterize fistula-in-ano, compared to surgical findings.

Methods

Hand-held 7.5 MHz TPUS was performed in the axial and sagittal planes in never-operated (Group 1, n=10) and recurrent (Group 2, n=10) cryptogenic fistulae where the ultrasonographer was blinded to the initial operative findings. This was compared with hydrogen peroxide-enhanced EAUS using a 7.5 MHz rotating probe, assessing the fistula anatomy, site of the internal opening, confirmation of Goodsall’s rule and the presence of secondary tracks, abscess collections and significant horsehoeing of the track.

Results

Overall sensitivity for the detection of trans-sphincteric and extrasphincteric fistulae was 100% using both techniques with a 90% sensitivity for TPUS and an 85% sensitivity for EAUS in the prediction of the internal fistula opening site. The TPUS sensitivity for horseshoeing was poor (28.6%) as was the detection of ancillary abscesses confirmed at surgery (63.6%) but TPUS demonstrated rectovaginal fistulae.

Conclusion

TPUS is a novel technique for use in perirectal infection which has a significant learning curve but which is highly accurate for prediction of the anatomy of complex recurrent as well as simple anal fistulae.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. P. Zbar.

Additional information

An erratum to this article is available at http://dx.doi.org/10.1007/s10151-006-0317-7.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zbar, A.P., Oyetunji, R.O. & Gill, R. Transperineal versus hydrogen peroxide-enhanced endoanal ultrasonography in never operated and recurrent cryptogenic fistula-in-ano: a pilot study. Tech Coloproctol 10, 297–302 (2006). https://doi.org/10.1007/s10151-006-0296-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10151-006-0296-8

Key words

Navigation