Skip to main content
Log in

Ventricular assist device infection necessitating device exchange following extensive myocardial resection

  • Case Report
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

A 14-year-old boy undergoing long-term mechanical circulatory support with a left ventricular assist device (LVAD) developed myocardial abscess resulting from cannula exit-site infection. This critically ill patient was successfully treated with LVAD replacement and omentopexy following extensive myocardial debridement. Although the use of artificial materials in the face of active infection is not ideal, other options including LVAD explantation or urgent heart transplantation are not always feasible depending on the patient’s cardiac function and the availability of a donor heart. Under such circumstances, LVAD replacement might be the only measure available that could save patients who otherwise would not survive.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zierer A, Melby SJ, Voeller RK, Guthrie TJ, Ewald GA, Shelton K, Pasque MK, Moon MR, Damiano RJ Jr, Moazami N. Lateonset driveline infections: the Achilles’ heel of prolonged left ventricular assist device support. Ann Thorac Surg 2007;84:515–520

    Article  PubMed  Google Scholar 

  2. Pasque MK, Hanselman T, Shelton K, Kehoe-Huck BA, Hedges R, Cassivi SD, Ewald GA, Rogers JG. Surgical management of Novacor drive-line exit site infections. Ann Thorac Surg 2002;74:1267–1268

    Article  PubMed  Google Scholar 

  3. Prendergast TW, Todd BA, Beyer AJ, Furukawa S, Eisen HJ, Addonizio VP, Browne BJ, Jeevanandam V. Management of left ventricular assist device infection with heart transplantation. Ann Thorac Surg 1997;64:142–147

    Article  CAS  PubMed  Google Scholar 

  4. Schulman AR, Martens TP, Christos PJ, Russo MJ, Comas GM, Cheema FH, Naseem TM, Wang R, Idrissi KA, Bailey SH, Naka Y. Comparisons of infection complications between continuous flow and pulsatile flow left ventricular assist devices. J Thorac Cardiovasc Surg 2007;133:841–842

    Article  PubMed  Google Scholar 

  5. Holman WL, Park SJ, Long JW, Weinberg A, Gupta L, Tierney AR, Adamson RM, Watson JD, Raines EP, Couper GS, Pagani FD, Burton NA, Miller LW, Naka Y; REMATCH Investigators. Infection in permanent circulatory support: experience from the REMATCH trial. J Heart Lung Transplant 2004;23:1359–1365

    Article  PubMed  Google Scholar 

  6. Saito S, Matsumiya G, Sakaguchi T, Fujita T, Kuratani T, Ichikawa H, Sawa Y. Long-term medical control of inflow cuff infection in a patient with a left ventricular assist system. J Artif Organs 2009;12:58–60

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshiki Sawa.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Adachi, I., Matsumiya, G., Sakaguchi, T. et al. Ventricular assist device infection necessitating device exchange following extensive myocardial resection. J Artif Organs 12, 271–273 (2009). https://doi.org/10.1007/s10047-009-0478-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-009-0478-z

Key words

Navigation