Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart

  • Brief Communication
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Transcutaneous energy transmission (TET) that uses electromagnetic induction between the external and internal coils of a transformer is the most promising method to supply driving energy to a totally implantable artificial heart without invasion. Induction-heating (IH) cookers generate magnetic flux, and if a cooker is operated near a transcutaneous transformer, the magnetic flux generated will link with the external and internal coils of the transcutaneous transformer. This will affect the performance of the TET and the artificial heart system. Hence, it is necessary to improve the magnetic field immunity of the TET system. During operation of the system, if the transcutaneous transformer is in close proximity to an IH cooker, the electric power generated by the cooker and coupled to the transformer can drive the artificial heart system. To prevent this coupling, the external coil was shielded with a conductive shield that had a slit in it. This reduces the coupling between the transformer and the magnetic field generated by the induction cooker. However, the temperature of the shield increased due to heating by eddy currents. The temperature of the shield can be reduced by separating the IH cooker and the shield.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Yamamoto T, Koshiji K, Tsukahara K, Tatsumi E, Taenaka Y, Takano H, Shiba K. Externally coupled transcutaneous energy transmission system for totally implantable artificial hearts — detection of abnormal coupling caused by misalignment and air gap in the ferrite core junction of the transcutaneous transformer. Trans JSMBE 2005;43(2):261–267

    Google Scholar 

  2. Shiba K, Shu E, Koshiji K, Tsuchimoto K, Tsukahara K, Masuzawa T, Kakuta Y, Tatsumi E, Taenaka Y, Takano H. Transcutaneous energy transmission system for a totally implantable total artificial heart — design and in vivo evaluation of the energy backup system. J Artif Organs 2000;1:24–30

    Google Scholar 

  3. Yamamoto T, Koshiji K, Nawa Y, Ikeda Y, Yanagi M, Homma A, Tatsumi E, Taenaka Y. Transcutaneous energy transmission system for a totally implantable artificial heart in case using external battery. In: IFMBE Proceedings — World Congress on Medical Physics and Biomedical Engineering 2006. Berlin: Springer, 2006;3026–3029

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takahiko Yamamoto.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yamamoto, T., Koshiji, K., Homma, A. et al. Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart. J Artif Organs 11, 238–240 (2008). https://doi.org/10.1007/s10047-008-0435-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-008-0435-2

Key words

Navigation