Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas

  • ORIGINAL ARTICLE
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

To produce a long-life, stable, miniature glucose sensor for a wearable artificial endocrine pancreas (WAEP), we developed a novel microneedle-type glucose sensor using polyimide, designated the PI sensor (outer diameter, 0.3 mm; length, 16 mm), and investigated its characteristics in vitro and in vivo. In the in vitro study, we tested the sensor in 0.9% NaCl solution with varying glucose concentrations and observed an excellent linear relationship between the sensor output and glucose concentration (range: 0–500 mg/100 ml). In in vivo experiments, the PI sensor was inserted into the abdominal subcutaneous tissue of beagle dogs (n = 5), and interstitial fluid glucose concentrations were monitored after sensor calibration. Simultaneously, blood glucose concentrations were also monitored continuously with another PI sensor placed intravenously. The correlation and time delay between subcutaneous tissue glucose (Y) and blood glucose concentrations (X: 30–350 mg/100 ml) were Y = 1.03X + 7.98 (r = 0.969) and 6.6 ± 1.2 min, respectively. We applied the new WAEP system/PI sensor and an intravenous insulin infusion algorithm developed previously for glycemic control in diabetic dogs. The use of the WAEP system resulted in excellent glycemic control after an oral glucose challenge of 1.5 g/kg (post-challenge blood glucose levels: 176 ± 18 mg/100 ml at 65 min and 93 ± 23 mg/100 ml at 240 min), without any hypoglycemia. Thus, we confirmed that our new PI sensor has excellent sensor characteristics in vitro and in vivo. The new WAEP using this sensor is potentially suitable for clinical application.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. J Mastrototaro (1999) ArticleTitleThe MiniMed continuous glucose monitoring system (CGMS) J Pediatr Endocrinol Metab 12 Suppl l3 751–758

    Google Scholar 

  2. M Schoemaker E Andreis J Roper R Kotulla V Lodwig K Obermaier P Stephan W Reuschling M Rutschmann R Schwaninger U Wittmann H Rinne H Kontschieder W Strohmeier (2003) ArticleTitleThe SCGM1 system: subcutaneous continuous glucose monitoring based on microdialysis technique Diabetes Technol Ther 5 599–608 Occurrence Handle14511414 Occurrence Handle1:CAS:528:DC%2BD3sXmsFWisLw%3D Occurrence Handle10.1089/152091503322250613

    Article  PubMed  CAS  Google Scholar 

  3. B Aussedat M Dupire-Angel R Gifford JC Klein GS Wilson G Reach (2000) ArticleTitleInterstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring Am J Physiol Endocrinol Metab 278 E716–E728 Occurrence Handle10751207 Occurrence Handle1:CAS:528:DC%2BD3cXis12iur0%3D

    PubMed  CAS  Google Scholar 

  4. K Rebrin GM Steil WP Van Antwerp JJ Mastrototaro (1999) ArticleTitleSubcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring Am J Physiol Endocrinol Metab 277 E561–E571 Occurrence Handle1:CAS:528:DyaK1MXmt1alsb4%3D

    CAS  Google Scholar 

  5. E Renard G Costalat J Bringer (2002) ArticleTitleFrom external to implantable insulin pump: can we close the loop? Diabetes Metab 28 2S19–2S25 Occurrence Handle12442060 Occurrence Handle1:STN:280:DC%2BD38notVyrsg%3D%3D

    PubMed  CAS  Google Scholar 

  6. GM Steil AE Panteleon K Rebrin (2004) ArticleTitleClosed-loop insulin delivery – the path to physiological glucose control Adv Drug Deliv Rev 56 125–144 Occurrence Handle14741112 Occurrence Handle1:CAS:528:DC%2BD2cXkvFyqug%3D%3D Occurrence Handle10.1016/j.addr.2003.08.011

    Article  PubMed  CAS  Google Scholar 

  7. K Nishida M Sakakida K Ichinose T Uemura M Uehara K Kajiwara T Miyata M Shichiri K Ishihara N Nakabayashi (1995) ArticleTitleDevelopment of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate Med Prog Technol 21 91–103 Occurrence Handle7565400 Occurrence Handle1:STN:280:BymD2crgt1E%3D

    PubMed  CAS  Google Scholar 

  8. M Shichiri R Kawamori (1985) Optimized algorithms for closed-loop glycemic control systems JBM Albisser J Schrezenmeir L Lehmann (Eds) Computer systems for insulin adjustment in diabetes mellitus Pancscienta-Verlag Hedingen, Switzerland 171–183

    Google Scholar 

  9. Y Hashiguchi M Sakakida K Nishida T Uemura K Kajiwara M Shichiri (1994) ArticleTitleDevelopment of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method Diabetes Care 17 387–396 Occurrence Handle8062605 Occurrence Handle1:STN:280:ByuA2c7gtVA%3D

    PubMed  CAS  Google Scholar 

  10. M Shichiri R Kawamori Y Yamasaki N Hakui H Abe (1982) ArticleTitleWearable artificial endocrine pancreas with needle-type glucose sensor Lancet 2 1129–1131 Occurrence Handle6128452 Occurrence Handle1:CAS:528:DyaL3sXit1WktLw%3D Occurrence Handle10.1016/S0140-6736(82)92788-X

    Article  PubMed  CAS  Google Scholar 

  11. SK Garg RO Potts NR Ackerman SJ Fermi JA Tamada HP Chase (1999) ArticleTitleCorrelation of fingerstick blood glucose measurements with GlucoWatch Biographer glucose results in young subjects with type 1 diabetes Diabetes Care 22 1708–1714 Occurrence Handle10526740 Occurrence Handle1:STN:280:DyaK1MvlsFKlsg%3D%3D

    PubMed  CAS  Google Scholar 

  12. JA Tamada SK Garg L Janovic KR Pitzer SJ Fermi RO Potts (1999) ArticleTitleNoninvasive glucose monitoring/comprehensive clinical results JAMA 282 1839–1844 Occurrence Handle10573275 Occurrence Handle1:STN:280:DC%2BD3c%2Fjsl2ntA%3D%3D Occurrence Handle10.1001/jama.282.19.1839

    Article  PubMed  CAS  Google Scholar 

  13. J Bantle W Thomas (1997) ArticleTitleGlucose measurement in patients with diabetes mellitus with dermal interstitial fluid J Lab Clin Med 130 436–441 Occurrence Handle9358083 Occurrence Handle1:CAS:528:DyaK2sXntlOlurw%3D Occurrence Handle10.1016/S0022-2143(97)90044-5

    Article  PubMed  CAS  Google Scholar 

  14. FJ Service PC O'Brien SD Wise S Ness SM LeBlanc (1997) ArticleTitleDermal interstitial glucose as an indicator of ambient glycemia Diabetes Care 20 1426–1429 Occurrence Handle9283791 Occurrence Handle1:STN:280:ByiH38bksVU%3D

    PubMed  CAS  Google Scholar 

  15. DS Bindra Y Zhang GS Wilson R Sternberg DR Thevenot D Moatti G Reach (1991) ArticleTitleDesign and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring Anal Chem 63 1692–1696 Occurrence Handle1789439 Occurrence Handle1:CAS:528:DyaK3MXltV2muro%3D Occurrence Handle10.1021/ac00017a008

    Article  PubMed  CAS  Google Scholar 

  16. SJ Updike MC Shults BJ Gilligan RK Rhodes (2000) ArticleTitleSubcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration Diabetes Care 23 208–214 Occurrence Handle10868833 Occurrence Handle1:CAS:528:DC%2BD3cXnvVymtrc%3D

    PubMed  CAS  Google Scholar 

  17. CP Quinn MV Pishko DW Schmidtke M Ishikava JG Wagner P Raskin JA Hubbell A Heller (1995) ArticleTitleKinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors Am J Physiol 269 E155–E161 Occurrence Handle7631771 Occurrence Handle1:CAS:528:DyaK2MXnt1Giu7c%3D

    PubMed  CAS  Google Scholar 

  18. J Kost S Mitragotri RA Gabbay M Pishko R Langer (2000) ArticleTitleTransdermal monitoring of glucose and other analytes using ultrasound Nature Med 6 347–350 Occurrence Handle10700240 Occurrence Handle1:CAS:528:DC%2BD3cXhslygs7Y%3D Occurrence Handle10.1038/73213

    Article  PubMed  CAS  Google Scholar 

  19. L Heinemann G Schmelzeisen-Redeker (1998) ArticleTitleNon-invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors Diabetologia 41 848–854 Occurrence Handle9686929 Occurrence Handle1:CAS:528:DyaK1cXktFKkurY%3D Occurrence Handle10.1007/s001250050998

    Article  PubMed  CAS  Google Scholar 

  20. J Pickup L McCartney O Rolinski D Birch (1999) ArticleTitleIn vivo glucose sensing for diabetes management: progress toward non-invasive monitoring Br Med J 319 1289–1293 Occurrence Handle1:STN:280:DC%2BD3c%2FisFKrug%3D%3D

    CAS  Google Scholar 

  21. JC Armour JY Luciasno BD McKean DA Gough (1990) ArticleTitleApplication of chronic intravascular blood glucose sensor in dogs Diabetes 39 1519–1526 Occurrence Handle2245876 Occurrence Handle1:CAS:528:DyaK3MXktVCgsbY%3D

    PubMed  CAS  Google Scholar 

  22. LC Clark SuffixJr LK Noyes RB Spokane R Sudan ML Miller (1988) ArticleTitleLong-term implantation of voltammetric oxidase/peroxide glucose sensors in the rat peritoneum Meth Enzymol 137 68–89 Occurrence Handle3374363 Occurrence Handle1:CAS:528:DyaL1cXkvFyktb8%3D

    PubMed  CAS  Google Scholar 

  23. MJ Tierney JA Tamada RO Potts RC Eastman K Pitzer NR Ackerman SJ Fermi (2000) ArticleTitleThe GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor Ann Med 32 632–641 Occurrence Handle11209971 Occurrence Handle1:CAS:528:DC%2BD3MXislCrtbc%3D

    PubMed  CAS  Google Scholar 

  24. SK Wolfson JF Tokarsky SJ Yao MA Krupper (1982) ArticleTitleGlucose concentration at possible sensor tissue implant sites Diabetes Care 5 162–165 Occurrence Handle7172978 Occurrence Handle1:CAS:528:DyaL38Xls1yrtLc%3D

    PubMed  CAS  Google Scholar 

  25. U Fischer R Ertle P Abel K Rebrin E Brunstein H Hahn von Dorsche EJ Freyse (1987) ArticleTitleAssessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs Diabetologia 30 940–945 Occurrence Handle3436490 Occurrence Handle1:CAS:528:DyaL1cXhvVaqtbc%3D Occurrence Handle10.1007/BF00295878

    Article  PubMed  CAS  Google Scholar 

  26. MJ Herfst H Van Rees (1978) ArticleTitleSuction blister fluid as a model for interstitial fluid in rats Arch Dermatol Res 263 325–334 Occurrence Handle742910 Occurrence Handle1:CAS:528:DyaE1MXotVyjsw%3D%3D Occurrence Handle10.1007/BF00446949

    Article  PubMed  CAS  Google Scholar 

  27. BM Jensen P Bjerring JS Christiansen H Orskov (1995) ArticleTitleGlucose content in human skin: relationship with blood glucose levels Scand J Clin Lab Invest 55 427–432 Occurrence Handle8545601 Occurrence Handle1:CAS:528:DyaK2MXoslKisro%3D

    PubMed  CAS  Google Scholar 

  28. DB Kuhns E DeCarlo DM Hawk JI Gallin (1992) ArticleTitleDynamics of the cellular and humoral components of the inflammatory response elicited in skin blisters in humans J Clin Invest 89 1734–1740 Occurrence Handle1601984 Occurrence Handle1:STN:280:By2B1M7ivVM%3D Occurrence Handle10.1172/JCI115775

    Article  PubMed  CAS  Google Scholar 

  29. RA Poulin GM Steil DM Moore M Ader RN Bergman (1994) ArticleTitleDynamics of glucose production and uptake are more closely related to insulin in hindlimb lymph than in thoracic duct lymph Diabetes 43 180–190 Occurrence Handle8288041 Occurrence Handle1:CAS:528:DyaK2cXht1Gmsbs%3D

    PubMed  CAS  Google Scholar 

  30. GM Steil J Richey JK Kim JK Wi K Rebrin RN Bergman JH Youn (1996) ArticleTitleExtracellular glucose distribution is not altered by insulin: analysis of plasma and interstitial l-glucose kinetics Am J Physiol Endocrinol Metab 271 E855–E864 Occurrence Handle1:CAS:528:DyaK28XntFyksrg%3D

    CAS  Google Scholar 

  31. F Schmidt WJ Sluiter AJM Schoonen (1993) ArticleTitleGlucose concentration in subcutaneous extracellular space Diabetes Care 16 695–700 Occurrence Handle8495606 Occurrence Handle1:STN:280:ByyB28rns1w%3D

    PubMed  CAS  Google Scholar 

  32. WA Kaptein RHA Kemper MHJ Ruiters K Venema RG Tiessen J Korf (1997) ArticleTitleMethodological aspects of glucose monitoring with a slow continuous subcutaneous and intravenous ultrafiltration system in rats Biosensors Bioelectronics 12 967–976 Occurrence Handle9451788 Occurrence Handle1:CAS:528:DyaK1cXkvVensg%3D%3D Occurrence Handle10.1016/S0956-5663(97)00052-3

    Article  PubMed  CAS  Google Scholar 

  33. KJ Wientjes AJ Schoonen (2001) ArticleTitleDetermination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers Int J Artif Organs 24 884–889 Occurrence Handle11831594 Occurrence Handle1:STN:280:DC%2BD387gtVCjug%3D%3D

    PubMed  CAS  Google Scholar 

  34. AL Aalders FJ Schmidt AJ Schoonen IR Broek AG Maessen H Doorenbos (1991) ArticleTitleDevelopment of a wearable glucose sensor: studies in healthy volunteers and in diabetic patients Int J Artif Organs 14 102–108 Occurrence Handle2037386 Occurrence Handle1:STN:280:By6B2cvkvVU%3D

    PubMed  CAS  Google Scholar 

  35. J Bolinder E Hagstrom U Ungerstedt P Arner (1989) ArticleTitleMicrodialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man Scand J Clin Lab Invest 49 465–474 Occurrence Handle2688061 Occurrence Handle1:CAS:528:DyaL1MXmt1yns7s%3D

    PubMed  CAS  Google Scholar 

  36. E Hagstrom P Arner P Engfeldt S Rossner J Bolinder (1990) ArticleTitleIn vivo subcutaneous adipose tissue glucose kinetics after glucose ingestion in obesity and fasting Scand J Clin Lab Invest 50 129–136 Occurrence Handle2339277 Occurrence Handle1:STN:280:By%2BB2M7pvVQ%3D

    PubMed  CAS  Google Scholar 

  37. LK Summers ML Clark SM Humphreys J Bugler KN Frayn (1999) ArticleTitleThe use of microdialysis to monitor rapid changes in glucose concentration Horm Metab Res 31 424–428 Occurrence Handle10450834 Occurrence Handle1:CAS:528:DyaK1MXksleksLo%3D Occurrence Handle10.1055/s-2007-978767

    Article  PubMed  CAS  Google Scholar 

  38. K Rebrin GM Steil (2000) ArticleTitleCan interstitial glucose assessment replace blood glucose measurements? Diabetes Tech Ther 2 461–472 Occurrence Handle1:CAS:528:DC%2BD3cXos1SgsLg%3D Occurrence Handle10.1089/15209150050194332

    Article  CAS  Google Scholar 

  39. M Nomura M Shichiri R Kawamori Y Yamasaki N Iwama H Abe (1984) ArticleTitleA mathematical insulin-secretion model and its validation in isolated rat pancreatic islets perifusion Comput Biomed Res 17 570–579 Occurrence Handle6391804 Occurrence Handle1:CAS:528:DyaL2MXktVekuw%3D%3D Occurrence Handle10.1016/0010-4809(84)90021-1

    Article  PubMed  CAS  Google Scholar 

  40. GM Steil K Rebrin R Janowski C Darwin MF Saad (2003) ArticleTitleModeling beta-cell insulin secretion – implications for closed-loop glucose homeostasis Diabetes Technol Ther 5 953–964 Occurrence Handle14709197 Occurrence Handle1:CAS:528:DC%2BD3sXpvVKks7s%3D Occurrence Handle10.1089/152091503322640999

    Article  PubMed  CAS  Google Scholar 

  41. R Hovorka LJ Chassin ME Wilinska V Canonico JA Akwi MO Federici M Massi-Benedetti I Hutzli C Zaugg H Kaufmann M Both T Vering HC Schaller L Schaupp M Bodenlenz TR Pieber (2004) ArticleTitleClosing the loop: the Adicol experience Diabetes Technol Ther 6 307–318 Occurrence Handle15198833 Occurrence Handle1:CAS:528:DC%2BD2cXksFGrsLs%3D Occurrence Handle10.1089/152091504774197990

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kenro Nishida MD, PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ichimori, S., Nishida, K., Shimoda, S. et al. Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas. J Artif Organs 9, 105–113 (2006). https://doi.org/10.1007/s10047-005-0326-8

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-005-0326-8

Key words

Navigation