Abstract
Purpose
To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal.
Materials and methods
Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at ≥6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated.
Results
The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4–4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2–9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients—adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2—however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6° to 61.1°, extension from 67.5° to 70.7°, and the flexion–extension arc of motion improved from 121.1° to 131.8°. The flexion and flexion–extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication.
Conclusions
Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
Similar content being viewed by others
References
Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322
Downing ND, Karantana A (2008) A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 90:1271–1275
Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient-volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68:992–998
Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67
Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31:359–365
Bhattacharyya T, Wadgaonkar AD (2008) Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases. J Bone Joint Surg Am 90:401–403
Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34:471–474
Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33:164–167
Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719
Cognet JM, Dujardin C, Popescu A, Gouzou S, Simon P (2005) Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 91:476–481
Buzzell JE, Weikert DR, Watson JT, Lee DH (2008) Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 33:1144–1152
Müller ME (1987) Distal radius. In: Müller ME, Nazarian S, Koch P, Schatzker J (eds) AO classification of fractures. etc. Springer, Berlin, pp 106–115
Jacques G (1981) Atlas of human limb joints. Springer, Berlin, p 182
Park JH, Hagopian J, Ilyas AM (2010) Variable-angle locking screw volar plating of distal radius fractures. Hand Clin 26:373–380
Acknowledgments
The authors report no benefits, grants, or assistance from any party.
Conflict of interest
No funds were received in support of this study.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Komura, S., Tanahashi, H., Yamada, Y. et al. Distal plate placement for distal radius fractures limits wrist motion. Eur J Orthop Surg Traumatol 22, 29–34 (2012). https://doi.org/10.1007/s00590-011-0809-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-011-0809-7